Verification Scheme of Measuring Instruments for Colorimetry
time:
2024-06-29 13:30:50
- JJG 2029-2006
- in force
Standard ID:
JJG 2029-2006
Standard Name:
Verification Scheme of Measuring Instruments for Colorimetry
Chinese Name:
色度计量器具检定系统表
Standard category:
National Metrology Standard (JJ)
-
Date of Release:
2006-05-23 -
Date of Implementation:
2006-11-23
Standard ICS number:
Metrology and measurement, physical phenomena>>Optics and optical measurement>>17.180.20 Measurement of color and lightChina Standard Classification Number:
General>>Metrology>>A60 Optical Metrology
alternative situation:
Replacement of JJG 2029-1989
publishing house:
China Metrology PressISBN:
155026-2173Publication date:
2006-11-23
Drafter:
Ma Yu, Lin Yige, etc.Drafting Organization:
China National Institute of MetrologyFocal point Organization:
National Optical Metrology Technical CommitteePublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine

Skip to download
Summary:
JJG 2029-2006 Colorimetric Instrument Verification System Table JJG2029-2006 Standard Download Decompression Password: www.bzxz.net
This verification system table is applicable to the verification of colorimetric instruments on the surface of objects. It specifies the purpose of the national benchmark of colorimetric units, the full set of basic metrological instruments included in the benchmark, the basic metrological parameters of the benchmark, the procedure for transferring colorimetric values to working metrological instruments with the help of working benchmarks and standard metrological instruments, and points out its uncertainty and basic verification methods. Colorimetric measurement is divided into surface colorimetric measurement and light source colorimetric measurement. The colorimetric measurement involved in this verification system table refers only to surface colorimetric measurement.
This verification system table is applicable to the verification of colorimetric instruments on the surface of objects. It specifies the purpose of the national benchmark of colorimetric units, the full set of basic metrological instruments included in the benchmark, the basic metrological parameters of the benchmark, the procedure for transferring colorimetric values to working metrological instruments with the help of working benchmarks and standard metrological instruments, and points out its uncertainty and basic verification methods. Colorimetric measurement is divided into surface colorimetric measurement and light source colorimetric measurement. The colorimetric measurement involved in this verification system table refers only to surface colorimetric measurement.

Some standard content:
National Metrology Verification System Table of the People's Republic of China JJG2029-2006
Colorimetric Measuring Instruments
Measuring Instruments for Colorimetry2006-05-23 Issued
Implementation on 2006-11-23
The General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China issued JJG2029-2006
Verification Scheme of Measuring Instruments for Colorimetry
JJG2029-2006
Replaces JJG2029-1989
This verification system table was approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on May 23, 2006, and came into effect on November 23, 2006.
Responsible unit: National Technical Committee for Optical Metrology Drafting unit: China National Institute of Metrology This calibration system table is interpreted by the National Technical Committee for Optical Metrology Main drafters of this system table:
Lin Daige
Chen Xiaju
Participating drafters:
JJG2029—2006
(China National Institute of Metrology)
(China National Institute of Metrology)
(China National Institute of Metrology)
(China National Institute of Metrology)
1 Scope
2 Metrology Reference instruments
2.1 National reference for colorimetry
2.2 National working reference for colorimetry
3 Metrological standard instruments
3.1 Primary standard color plates and secondary standard color plates3.2 Measurement methods
4 Working measuring instruments
5 Colorimetric measuring instrument verification system table block diagram
JJG2029—2006www.bzxz.net
1 Scope
JJG2029—2006
Colorimetric measuring instrument verification system table
This verification system table is applicable to the verification of colorimetric measuring instruments for the surface of objects. It specifies the purpose of the national reference for colorimetric units, the full set of basic measuring instruments included in the reference, the basic metrological parameters of the reference, the procedure for transferring colorimetric values to working measuring instruments with the help of working references and standard measuring instruments, and points out its uncertainty and basic verification methods, etc. Colorimetry is divided into surface colorimetry and light source colorimetry. The colorimetry involved in this verification system table refers only to surface colorimetry.
2 Measurement reference instruments
2.1 National colorimetry reference
2.1.1 The national colorimetry reference is used to reproduce the colorimetric measurement unit, and transmit the value to the whole country through the colorimetric working reference plate and the first-level standard white plate, the second-level standard white plate and the special standard reflector to ensure the accuracy and uniformity of the colorimetric value in my country. The national colorimetric reference consists of a reference device and a reference white plate. 2.1.2 The national colorimetric reference device can realize the absolute measurement of the spectral reflectance factor, and the reference white plate is an approximate perfect reflecting diffuser. The value reproduced by the national colorimetric reference is the absolute spectral diffuse reflectance factor, and the corresponding colorimetric value is calculated through the standard illuminant and standard colorimetric observer specified by the International Commission on Illumination (CIE). my country has established a national colorimetric reference under 0/d conditions. 0/d condition refers to the geometric condition of illumination/observation, that is, the light source illuminates the sample directly, and the reflected light is diffused by the integrating sphere and received by the detector. 2.1.3 The measurement range and uncertainty of the national chromaticity standard are shown in Table 1. Table 1 Uncertainty of the national chromaticity standard
Benchmark name
0/d condition National chromaticity standard
2.2 National chromaticity working standard
Measurement range
Y≥90
0.2800x, 0.4500
Uncertainty
U(Y)=0.8(K=2)
U(), U(y)=0.0022(k=2)
2.2.1 The value transfer from the standard to the working standard is carried out on the chromaticity standard device. The national chromaticity working standard is obtained by comparative measurement of the chromaticity standard value transfer device. The method is: use the spectral diffuse reflection factor of the reference plate to calibrate the colorimetric reference device within the corresponding wavelength range, and measure the spectral diffuse reflection factor of the working reference plate by comparison method.
The colorimetric reference white plate is a sulfuric acid lock spray plate, which requires a high diffuse reflection factor, good diffusion performance, and a small spectral selectivity 1
JJG2029——2006
. The stimulus value Y and color coordinates under the Dss lighting body and CIE1964 standard colorimetric observer (i.e.: 10° field of view) are in the range of: Y≥90, 0.2800
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Colorimetric Measuring Instruments
Measuring Instruments for Colorimetry2006-05-23 Issued
Implementation on 2006-11-23
The General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China issued JJG2029-2006
Verification Scheme of Measuring Instruments for Colorimetry
JJG2029-2006
Replaces JJG2029-1989
This verification system table was approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on May 23, 2006, and came into effect on November 23, 2006.
Responsible unit: National Technical Committee for Optical Metrology Drafting unit: China National Institute of Metrology This calibration system table is interpreted by the National Technical Committee for Optical Metrology Main drafters of this system table:
Lin Daige
Chen Xiaju
Participating drafters:
JJG2029—2006
(China National Institute of Metrology)
(China National Institute of Metrology)
(China National Institute of Metrology)
(China National Institute of Metrology)
1 Scope
2 Metrology Reference instruments
2.1 National reference for colorimetry
2.2 National working reference for colorimetry
3 Metrological standard instruments
3.1 Primary standard color plates and secondary standard color plates3.2 Measurement methods
4 Working measuring instruments
5 Colorimetric measuring instrument verification system table block diagram
JJG2029—2006www.bzxz.net
1 Scope
JJG2029—2006
Colorimetric measuring instrument verification system table
This verification system table is applicable to the verification of colorimetric measuring instruments for the surface of objects. It specifies the purpose of the national reference for colorimetric units, the full set of basic measuring instruments included in the reference, the basic metrological parameters of the reference, the procedure for transferring colorimetric values to working measuring instruments with the help of working references and standard measuring instruments, and points out its uncertainty and basic verification methods, etc. Colorimetry is divided into surface colorimetry and light source colorimetry. The colorimetry involved in this verification system table refers only to surface colorimetry.
2 Measurement reference instruments
2.1 National colorimetry reference
2.1.1 The national colorimetry reference is used to reproduce the colorimetric measurement unit, and transmit the value to the whole country through the colorimetric working reference plate and the first-level standard white plate, the second-level standard white plate and the special standard reflector to ensure the accuracy and uniformity of the colorimetric value in my country. The national colorimetric reference consists of a reference device and a reference white plate. 2.1.2 The national colorimetric reference device can realize the absolute measurement of the spectral reflectance factor, and the reference white plate is an approximate perfect reflecting diffuser. The value reproduced by the national colorimetric reference is the absolute spectral diffuse reflectance factor, and the corresponding colorimetric value is calculated through the standard illuminant and standard colorimetric observer specified by the International Commission on Illumination (CIE). my country has established a national colorimetric reference under 0/d conditions. 0/d condition refers to the geometric condition of illumination/observation, that is, the light source illuminates the sample directly, and the reflected light is diffused by the integrating sphere and received by the detector. 2.1.3 The measurement range and uncertainty of the national chromaticity standard are shown in Table 1. Table 1 Uncertainty of the national chromaticity standard
Benchmark name
0/d condition National chromaticity standard
2.2 National chromaticity working standard
Measurement range
Y≥90
0.2800x, 0.4500
Uncertainty
U(Y)=0.8(K=2)
U(), U(y)=0.0022(k=2)
2.2.1 The value transfer from the standard to the working standard is carried out on the chromaticity standard device. The national chromaticity working standard is obtained by comparative measurement of the chromaticity standard value transfer device. The method is: use the spectral diffuse reflection factor of the reference plate to calibrate the colorimetric reference device within the corresponding wavelength range, and measure the spectral diffuse reflection factor of the working reference plate by comparison method.
The colorimetric reference white plate is a sulfuric acid lock spray plate, which requires a high diffuse reflection factor, good diffusion performance, and a small spectral selectivity 1
JJG2029——2006
. The stimulus value Y and color coordinates under the Dss lighting body and CIE1964 standard colorimetric observer (i.e.: 10° field of view) are in the range of: Y≥90, 0.2800
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 10364-2002 Hydraulic check valve
- GBJ 134-1990 Civil air defense project construction and acceptance specification GBJ134-90
- HG/T 2065-1991 Technical requirements for paint preparation machines
- FZ/T 43015-2001 Mulberry silk knitted garments
- HG/T 3576-1989 Magnesium borate ore
- JB/T 7947-1999 Isobaric welding torch and cutting torch
- GB/T 4702.10-1985 Methods for chemical analysis of metallic chromium - Determination of copper content by copper reagent spectrophotometry
- GB/T 3254.2-1998 Chemical analysis method for antimony trioxide - Determination of arsenic content
- GB/T 13824-1992 Requirements for instruments for measuring vibration severity
- GB/T 13396-1992 China STANDARD recording code
- GB 12320-1998 Specifications for Chinese nautical charts
- HG/T 2275.3-1992 Determination of arsenic content in realgar ore
- YS/T 462-2003 Copper and copper alloy tube, rod and wire product defects
- HG/T 3050.2-2001 Rubber or plastic coated fabrics - Determination of properties of the whole roll - Part 2: Determination of total mass per unit area, coating mass per unit area
- GB/T 3653.1-1988 Chemical analysis methods for ferroboron - Alkali titration method for determination of boron content
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]