Packaging-Transport packages-Sinusoidal vibration test method at constant frequency
time:
2024-08-05 04:01:45
- GB/T 4857.7-1992
- Abolished
Standard ID:
GB/T 4857.7-1992
Standard Name:
Packaging-Transport packages-Sinusoidal vibration test method at constant frequency
Chinese Name:
包装 运输包装件 正弦定频振动试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1984-01-02 -
Date of Implementation:
1993-06-01 -
Date of Expiration:
2005-11-01
Standard ICS number:
Packaging and transportation of goods>>55.020 Packaging and transportation of goodsChina Standard Classification Number:
General>>Basic Standards>>A21 Environmental Conditions and General Test Methods
alternative situation:
GB 4857.7-1984; replaced by GB/T 4857.7-2005Procurement status:
=ISO 2247-85
Release date:
1984-12-28Review date:
2004-10-14Drafting Organization:
Electronic Standardization Institute of Ministry of Machinery and ElectronicsPublishing Department:
State Bureau of Technical Supervision

Skip to download
Summary:
This standard specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sinusoidal fixed frequency vibration test of transport packages. This standard is applicable to the assessment of the strength of transport packages under sinusoidal fixed frequency vibration and the protection of the packaging to the contents. It can be used as a single top test or as part of a series of tests. GB/T 4857.7-1992 Sinusoidal fixed frequency vibration test method for packaging transport packages GB/T4857.7-1992 Standard download decompression password: www.bzxz.net
This standard specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sinusoidal fixed frequency vibration test of transport packages. This standard is applicable to the assessment of the strength of transport packages under sinusoidal fixed frequency vibration and the protection of the packaging to the contents. It can be used as a single top test or as part of a series of tests.
This standard specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sinusoidal fixed frequency vibration test of transport packages. This standard is applicable to the assessment of the strength of transport packages under sinusoidal fixed frequency vibration and the protection of the packaging to the contents. It can be used as a single top test or as part of a series of tests.

Some standard content:
National Standard of the People's Republic of China
Packaging--Transport packages-Sinusoidal vibration test methodat constant frequency
GB/T 4857.7-92
ISO 2247—1985
Replaces GB 4857. 7—84
This standard equivalently adopts the international standard ISO2247—1985 Packaging—Complete and fully loaded transport packages—Fixed low frequency vibration
1 Subject content and scope of application
This standard specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sinusoidal constant frequency vibration test of transport packages.
This standard is applicable to the assessment of the strength of transport packages under sinusoidal constant frequency vibration and the protection ability of the packaging to the contents. It can be used as a single test or as part of a series of tests. 2 Reference standards
GB3538 Method for marking various parts of transport packages Temperature and humidity conditioning treatment of transport packages GB/T 4857.2
Test method for static load stacking of transport packages GB/T 4857.3
GB/T4857.17 General principles for preparing performance test outlines for transport packages GB/T4857.18 Quantitative data for preparing performance test outlines for transport packages 3 Test principle
Place the test sample on a vibration table to vibrate. The temperature and humidity conditions, test duration, maximum acceleration, test sample placement status and fixing method during the test are all predetermined. If necessary, a certain load can be added to the test sample to simulate the situation where the transport package is at the bottom of the stack and is subjected to a sinusoidal vibration environment.
4 Test equipment
The vibration table should have a sufficiently large size, sufficient strength, rigidity and load-bearing capacity. It is mounted on a mechanical structure that ensures that the vibration table surface remains horizontal during vibration. The height difference between the highest and lowest points of the table surface shall not exceed 10 mm. The vibration table may be equipped with:
2 low frame: to prevent the test sample from moving to the ends and sides during the test; b. high frame or other device: to prevent the load applied to the test sample from shifting during vibration; c. device to simulate the fixing method of the package during transportation. In addition, the vibration table shall comply with the requirements specified in 5.6.3. Approved by the State Administration of Technical Supervision on November 25, 1992 268
Implementation on June 1, 1993
5 Test procedure
5.1 Preparation of test samples
GB/T 4857.7-92
Prepare the test samples in accordance with the provisions of GB/T4857.17. The number of test samples is generally not less than 3. 5.2 Numbering of various parts of the test sample
Number various parts of the test sample according to the provisions of GB3538. 5.3 Pretreatment of the test sample
Select a condition to pretreat the test sample with temperature and humidity according to the provisions of GB/T4857.2. 5.4 Temperature and humidity conditions during the test
The test should be carried out under the same temperature and humidity conditions as those during the pretreatment. If the same conditions cannot be achieved, the test should be carried out under temperature and humidity conditions as close to them as possible.
5.5 Selection of test strength value
Select the test strength value according to the provisions of GB/T4857.18. 5.6 Test steps
5.6.1 Record the temperature and humidity of the test site.
5.6.2 Place the test sample on the vibration table in the predetermined state. The horizontal distance between the center (or center of gravity) of the bottom surface of the test sample and the center of the vibration table surface is within 10 mm. The test sample can be fixed on the vibration table or surrounded by a frame. If necessary, loads may be added to the test sample, and the loading procedure shall comply with the provisions of GB/T4857.3. 5.6.3 Make the vibration table vibrate between 3~~4.6Hz, and its maximum acceleration is 5~11m/s2. The duration of vibration shall be selected in accordance with the provisions of GB/T4857.18. The vertical component of the table motion shall be approximately sinusoidal, and the vibration table is allowed to have rotational motion. Note: If an instrument is used to measure the vibration degree, the accelerometer shall be placed close to the vibration table surface close to the test sample. However, certain protective measures shall be taken for the accelerometer to prevent contact with the test sample during the test. When the test is carried out with an acceleration of 11m/s, the appropriate frequency is not set by the instrument, but by the following setting method: First, let the vibration table vibrate at a frequency of about 2Hz, and then continuously increase the vibration frequency until a part of the test sample repeatedly leaves the table surface, so as to ensure that the test sample is subjected to a series of continuous and repeated impacts. 5.6.4 After the test, check the damage of the packaging and contents according to relevant standards and regulations, and analyze the test results. 6 Test reportbzxz.net
The test report shall include the following contents:
a. Name, specification, model, quantity, etc. of the contents; if simulated contents are used, detailed description shall be given;b. Number of test samples
Detailed description of the name, size, structure and material specifications, accessories, cushioning pads, supports, fixing methods, seals, c.
Bundling status and other protective measures of the packaging container:
The mass of the test samples and contents, in kilograms;d.
Description of the test equipment;
Fixing measures, whether a low frame or a high frame is used; whether a load is added. If a load is applied, indicate the weight of the applied load (in dry grams) and the duration of the load on the test sample. The state of the test sample during the test:
Pretreatment temperature and humidity conditions and time;
Temperature and relative humidity of the test site;
Vibration duration, acceleration and vibration frequency; k.
Test results: Any observed phenomenon that can help correctly interpret the test results should be recorded in detail; 269
Test result analysis,
GB/T4857.7—92
Indicate the difference between the test method used and this standard; Test date, signature of the tester, and seal of the test unit. Additional notes:
This standard was proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Fang Lina and Xu Yunchi. 270
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Packaging--Transport packages-Sinusoidal vibration test methodat constant frequency
GB/T 4857.7-92
ISO 2247—1985
Replaces GB 4857. 7—84
This standard equivalently adopts the international standard ISO2247—1985 Packaging—Complete and fully loaded transport packages—Fixed low frequency vibration
1 Subject content and scope of application
This standard specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sinusoidal constant frequency vibration test of transport packages.
This standard is applicable to the assessment of the strength of transport packages under sinusoidal constant frequency vibration and the protection ability of the packaging to the contents. It can be used as a single test or as part of a series of tests. 2 Reference standards
GB3538 Method for marking various parts of transport packages Temperature and humidity conditioning treatment of transport packages GB/T 4857.2
Test method for static load stacking of transport packages GB/T 4857.3
GB/T4857.17 General principles for preparing performance test outlines for transport packages GB/T4857.18 Quantitative data for preparing performance test outlines for transport packages 3 Test principle
Place the test sample on a vibration table to vibrate. The temperature and humidity conditions, test duration, maximum acceleration, test sample placement status and fixing method during the test are all predetermined. If necessary, a certain load can be added to the test sample to simulate the situation where the transport package is at the bottom of the stack and is subjected to a sinusoidal vibration environment.
4 Test equipment
The vibration table should have a sufficiently large size, sufficient strength, rigidity and load-bearing capacity. It is mounted on a mechanical structure that ensures that the vibration table surface remains horizontal during vibration. The height difference between the highest and lowest points of the table surface shall not exceed 10 mm. The vibration table may be equipped with:
2 low frame: to prevent the test sample from moving to the ends and sides during the test; b. high frame or other device: to prevent the load applied to the test sample from shifting during vibration; c. device to simulate the fixing method of the package during transportation. In addition, the vibration table shall comply with the requirements specified in 5.6.3. Approved by the State Administration of Technical Supervision on November 25, 1992 268
Implementation on June 1, 1993
5 Test procedure
5.1 Preparation of test samples
GB/T 4857.7-92
Prepare the test samples in accordance with the provisions of GB/T4857.17. The number of test samples is generally not less than 3. 5.2 Numbering of various parts of the test sample
Number various parts of the test sample according to the provisions of GB3538. 5.3 Pretreatment of the test sample
Select a condition to pretreat the test sample with temperature and humidity according to the provisions of GB/T4857.2. 5.4 Temperature and humidity conditions during the test
The test should be carried out under the same temperature and humidity conditions as those during the pretreatment. If the same conditions cannot be achieved, the test should be carried out under temperature and humidity conditions as close to them as possible.
5.5 Selection of test strength value
Select the test strength value according to the provisions of GB/T4857.18. 5.6 Test steps
5.6.1 Record the temperature and humidity of the test site.
5.6.2 Place the test sample on the vibration table in the predetermined state. The horizontal distance between the center (or center of gravity) of the bottom surface of the test sample and the center of the vibration table surface is within 10 mm. The test sample can be fixed on the vibration table or surrounded by a frame. If necessary, loads may be added to the test sample, and the loading procedure shall comply with the provisions of GB/T4857.3. 5.6.3 Make the vibration table vibrate between 3~~4.6Hz, and its maximum acceleration is 5~11m/s2. The duration of vibration shall be selected in accordance with the provisions of GB/T4857.18. The vertical component of the table motion shall be approximately sinusoidal, and the vibration table is allowed to have rotational motion. Note: If an instrument is used to measure the vibration degree, the accelerometer shall be placed close to the vibration table surface close to the test sample. However, certain protective measures shall be taken for the accelerometer to prevent contact with the test sample during the test. When the test is carried out with an acceleration of 11m/s, the appropriate frequency is not set by the instrument, but by the following setting method: First, let the vibration table vibrate at a frequency of about 2Hz, and then continuously increase the vibration frequency until a part of the test sample repeatedly leaves the table surface, so as to ensure that the test sample is subjected to a series of continuous and repeated impacts. 5.6.4 After the test, check the damage of the packaging and contents according to relevant standards and regulations, and analyze the test results. 6 Test reportbzxz.net
The test report shall include the following contents:
a. Name, specification, model, quantity, etc. of the contents; if simulated contents are used, detailed description shall be given;b. Number of test samples
Detailed description of the name, size, structure and material specifications, accessories, cushioning pads, supports, fixing methods, seals, c.
Bundling status and other protective measures of the packaging container:
The mass of the test samples and contents, in kilograms;d.
Description of the test equipment;
Fixing measures, whether a low frame or a high frame is used; whether a load is added. If a load is applied, indicate the weight of the applied load (in dry grams) and the duration of the load on the test sample. The state of the test sample during the test:
Pretreatment temperature and humidity conditions and time;
Temperature and relative humidity of the test site;
Vibration duration, acceleration and vibration frequency; k.
Test results: Any observed phenomenon that can help correctly interpret the test results should be recorded in detail; 269
Test result analysis,
GB/T4857.7—92
Indicate the difference between the test method used and this standard; Test date, signature of the tester, and seal of the test unit. Additional notes:
This standard was proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Fang Lina and Xu Yunchi. 270
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 3114-1994 Copper and copper alloy flat wire
- HG/T 3032-1999 Determination of extractable formaldehyde in melamine formaldehyde molded products
- GB/T 584-1999 Marine flange cast steel stop valve
- HG/T 20519.8-1992 Equipment List
- GB/T 14530-1993 Technical requirements for wooden catalog cabinets for book supplies and equipment
- JB/T 4736-2002 Heads for steel pressure vessels with reinforced rings
- GB 12898-1991 National third- and fourth-class level measurement specifications
- JB/T 4713-1992 leg support
- GB/T 15120.4-1994 Identification card recording technology Part 4: Location of track 1 and track 2 of read-only track
- GB/T 8834-1988 Determination of relevant physical and mechanical properties of ropes
- GB/T 5009.66-2003 Analytical methods for hygienic standards of rubber nipples
- GB/T 26431-2010 Sweet pepper
- JB/T 8044-1999 Technical requirements for machine tool fixture parts and components
- GB/T 3358.1-1993 Terms for statistics. Part Ⅰ: Terms for general statistics
- NY 5101-2002 Environmental conditions for the production of pollution-free pears
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]