HG 3027-1988 Determination of plasticizer content in organic glass UV spectrometry
time:
2024-08-13 18:48:14
- HG 3027-1988
- in force
Standard ID:
HG 3027-1988
Standard Name:
Determination of plasticizer content in organic glass UV spectrometry
Chinese Name:
有机玻璃中增塑剂含量的测定方法紫外光谱法
Standard category:
Chemical industry standards (HG)
-
Date of Implementation:
1989-02-01
China Standard Classification Number:
Chemicals>>Synthetic Materials>>G32 Synthetic Resins, Plastics
alternative situation:
GB 9346-88

Skip to download
Summary:
HG 3027-1988 Determination of plasticizer content in organic glass UV spectrometry HG3027-1988 standard download decompression password: www.bzxz.net

Some standard content:
UDC 678.5:543.062
National Standard of the People's Republic of China
GB9346-88
Adjusted to: HG/ 3027-1P88
Determination of plasticizer content in polymethylmethacryiateUltraviolet spectrometry methodPublished on 1988-06-14
Published by the State Bureau of Standards
Implemented on 1989-02-01
National Standard of the People's Republic of China
Determination of plasticizer content in polymethylmethacrylate-Ultraviolet spectrometry method
1 Subject content and scope of application
UDC 678.5: 543
GB 9346.. 88
This standard specifies the ultraviolet spectroscopic determination method for the plasticizer dibutyl phthalate (BP) and dioctyl phthalate (DP) in cast organic glass (polymethyl methacrylate). This standard is applicable to the determination of the plasticizer DBP or DOP content in cast elastic transparent organic glass. 2 Principle
Dibutyl phthalate or dioctyl phthalate in chloroform solution has a characteristic absorption peak at a wavelength of 275nm under the action of ultraviolet light, which conforms to the L. Ramhert Beer law within a certain concentration range. The absorbance of chloroform in the glass sample is measured at 275nm, and the content of dibutyl phthalate or dioctyl phthalate is calculated by the working curve method.
3 Reagents
3.1 DBP: maximum concentration
3.2 DOP: content greater than 90%,
3.3 Methyl chloride, analytical grade,bzxz.net
3.4 Standard solution:
3.4.1 Weigh 0.05-0.07g of 1H1 (3.1) to the accuracy of 0.0001g, place in a 50ml volumetric flask, dilute to the mark with methyl chloride (3.3), mix, and the result is DBP standard solution. 3.4.2 Weigh 0.05-0.07g of DOP (3.2) to the accuracy of 0.0001g, place in a 50ml volumetric flask, dilute to the mark with methyl chloride (3.3), and the result is DOP standard solution. 4. Instruments
UV spectrophotometer.
5 The sample
should be particles or powders randomly taken from the organic glass. 6 Determination steps
6.1 Drawing line
Pipette 0.5.1.0, 1.5.2.0, 3.0ml of D13P standard solution (3.4.1), and dilute it to 25ml volume. Dilute it with trichloroethylene (3.3) without scale, mix it, and calculate the IBP concentration (mg/1) of each dilution. Take trifluoromethane used to prepare the standard solution (GB9346-88 approved by the Ministry of Chemical Industry of the People's Republic of China on May 13, 1988 and implemented on February 1, 1989) as a reference, and record the absorbance of each solution at a wavelength of 275nm. Draw a DBPT curve with the concentration of DB1 as the horizontal axis and the absorbance as the vertical axis.
Take 0.5, 1.0, 1.5, 2.0, 3.0 ml of DOP standard solution (3.4.2), repeat the above operation, and draw a DOP curve. 6.2 Determination
6.2.1 Weigh 0.03~0.08% of the sample, and make it accurate to 0.0001g, and place it in a 25ml volumetric flask, add 15~20ml of chloroform (3.3), and after the sample is completely dissolved, dilute it to the scale with chloroform and mix it. 6.2.2 Transfer part of the solution to be tested (6.2.1) into a 10mm quartz colorimetric glass, using the chloroform dissolved in the sample as the ratio, and measure its absorbance at a wavelength of 275m on a UV spectrophotometer under the conditions corresponding to the curve drawn above, and find the corresponding DHP or DOP concentration (mg/!) from the working curve.
7 Calculation of results
Calculate the percentage of plasticizer DBP or DOP as follows: c +× 10-4
Where: c——plasticizer DBP or DOP concentration found from the working curve, mg/L: one sample solution volume, ml:
sample volume, sample.
8 Allowable difference
8.1 For samples with a DBP content of 2% to 13%, the allowable difference between two repeated measurements should not be greater than 0.14%. 8.2 For samples with a DBP content of 2% to 13%, the allowable difference between the values measured once in each laboratory should not be greater than 0.33%. 8.3 For samples with a DOP content of 0.5% to 5.0%, the allowable difference between two repeated measurements and the allowable difference between the values measured once in each laboratory should not be greater than the values listed in the following table. Plasticizer DOP content
0.50 ~ 2.00
2.00 -3.50
-3.50 ~ 5.00
The allowable difference between two repeated determinations
The allowable difference between the single determination values in each experiment is 0.19
Note: The precision data were determined by eight laboratories from June 1986 to March 1987 in accordance with GB4471 "Determination of Repeatability and Reproducibility of Laboratory Tests for Chemical Products - Test Methods for Precision", and the tests were conducted on 5 levels of DBP and DOP. 9 Test report
The test report should include the following contents:
, indicate that it is in accordance with this national standard:
b, material name, specification, batch number, source or manufacturerc. The average of two determinations,
d, tester
e test date.
Additional Notes:
GB 9346--8B
This standard was drafted by the National Technical Committee for Plastic Standardization. This standard was drafted by Hai Shanhu Chemical Factory. The main drafters of this standard were Zhang Nianhong and Wu Yi. National Standard of the People's Republic of China Determination of plasticizer content in organic glass Ultraviolet spectrum GB 9346-88 Published by China Standard Press (Beijing Fuwai Sanlihe) Published by China Standard Press Beijing Printing Factory Guangji Xinhuazhe Store Beijing Distribution Office Sold by Xinhua Bookstores in various places Copyright exclusive Reproduction prohibited Format 880×12301/16 Printing sheet 1/2 Number 5 000 First edition in February 1389 Second edition in February 1989 Number of copies 1-2000 2 55: 155066-1 Price 0.40 106-36 88-988 89
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
GB9346-88
Adjusted to: HG/ 3027-1P88
Determination of plasticizer content in polymethylmethacryiateUltraviolet spectrometry methodPublished on 1988-06-14
Published by the State Bureau of Standards
Implemented on 1989-02-01
National Standard of the People's Republic of China
Determination of plasticizer content in polymethylmethacrylate-Ultraviolet spectrometry method
1 Subject content and scope of application
UDC 678.5: 543
GB 9346.. 88
This standard specifies the ultraviolet spectroscopic determination method for the plasticizer dibutyl phthalate (BP) and dioctyl phthalate (DP) in cast organic glass (polymethyl methacrylate). This standard is applicable to the determination of the plasticizer DBP or DOP content in cast elastic transparent organic glass. 2 Principle
Dibutyl phthalate or dioctyl phthalate in chloroform solution has a characteristic absorption peak at a wavelength of 275nm under the action of ultraviolet light, which conforms to the L. Ramhert Beer law within a certain concentration range. The absorbance of chloroform in the glass sample is measured at 275nm, and the content of dibutyl phthalate or dioctyl phthalate is calculated by the working curve method.
3 Reagents
3.1 DBP: maximum concentration
3.2 DOP: content greater than 90%,
3.3 Methyl chloride, analytical grade,bzxz.net
3.4 Standard solution:
3.4.1 Weigh 0.05-0.07g of 1H1 (3.1) to the accuracy of 0.0001g, place in a 50ml volumetric flask, dilute to the mark with methyl chloride (3.3), mix, and the result is DBP standard solution. 3.4.2 Weigh 0.05-0.07g of DOP (3.2) to the accuracy of 0.0001g, place in a 50ml volumetric flask, dilute to the mark with methyl chloride (3.3), and the result is DOP standard solution. 4. Instruments
UV spectrophotometer.
5 The sample
should be particles or powders randomly taken from the organic glass. 6 Determination steps
6.1 Drawing line
Pipette 0.5.1.0, 1.5.2.0, 3.0ml of D13P standard solution (3.4.1), and dilute it to 25ml volume. Dilute it with trichloroethylene (3.3) without scale, mix it, and calculate the IBP concentration (mg/1) of each dilution. Take trifluoromethane used to prepare the standard solution (GB9346-88 approved by the Ministry of Chemical Industry of the People's Republic of China on May 13, 1988 and implemented on February 1, 1989) as a reference, and record the absorbance of each solution at a wavelength of 275nm. Draw a DBPT curve with the concentration of DB1 as the horizontal axis and the absorbance as the vertical axis.
Take 0.5, 1.0, 1.5, 2.0, 3.0 ml of DOP standard solution (3.4.2), repeat the above operation, and draw a DOP curve. 6.2 Determination
6.2.1 Weigh 0.03~0.08% of the sample, and make it accurate to 0.0001g, and place it in a 25ml volumetric flask, add 15~20ml of chloroform (3.3), and after the sample is completely dissolved, dilute it to the scale with chloroform and mix it. 6.2.2 Transfer part of the solution to be tested (6.2.1) into a 10mm quartz colorimetric glass, using the chloroform dissolved in the sample as the ratio, and measure its absorbance at a wavelength of 275m on a UV spectrophotometer under the conditions corresponding to the curve drawn above, and find the corresponding DHP or DOP concentration (mg/!) from the working curve.
7 Calculation of results
Calculate the percentage of plasticizer DBP or DOP as follows: c +× 10-4
Where: c——plasticizer DBP or DOP concentration found from the working curve, mg/L: one sample solution volume, ml:
sample volume, sample.
8 Allowable difference
8.1 For samples with a DBP content of 2% to 13%, the allowable difference between two repeated measurements should not be greater than 0.14%. 8.2 For samples with a DBP content of 2% to 13%, the allowable difference between the values measured once in each laboratory should not be greater than 0.33%. 8.3 For samples with a DOP content of 0.5% to 5.0%, the allowable difference between two repeated measurements and the allowable difference between the values measured once in each laboratory should not be greater than the values listed in the following table. Plasticizer DOP content
0.50 ~ 2.00
2.00 -3.50
-3.50 ~ 5.00
The allowable difference between two repeated determinations
The allowable difference between the single determination values in each experiment is 0.19
Note: The precision data were determined by eight laboratories from June 1986 to March 1987 in accordance with GB4471 "Determination of Repeatability and Reproducibility of Laboratory Tests for Chemical Products - Test Methods for Precision", and the tests were conducted on 5 levels of DBP and DOP. 9 Test report
The test report should include the following contents:
, indicate that it is in accordance with this national standard:
b, material name, specification, batch number, source or manufacturerc. The average of two determinations,
d, tester
e test date.
Additional Notes:
GB 9346--8B
This standard was drafted by the National Technical Committee for Plastic Standardization. This standard was drafted by Hai Shanhu Chemical Factory. The main drafters of this standard were Zhang Nianhong and Wu Yi. National Standard of the People's Republic of China Determination of plasticizer content in organic glass Ultraviolet spectrum GB 9346-88 Published by China Standard Press (Beijing Fuwai Sanlihe) Published by China Standard Press Beijing Printing Factory Guangji Xinhuazhe Store Beijing Distribution Office Sold by Xinhua Bookstores in various places Copyright exclusive Reproduction prohibited Format 880×12301/16 Printing sheet 1/2 Number 5 000 First edition in February 1389 Second edition in February 1989 Number of copies 1-2000 2 55: 155066-1 Price 0.40 106-36 88-988 89
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 3411.27-1999 Slotting tool bar dimensions
- JB/T 9012-1999 Side-mounted forklift
- GBJ 105-1987 Building structure drawing standard GBJ105-87
- JJF 1103-2003 Evaluation for Computerized Data Acquisition Systems of Universal Testing Machines
- GB 15193.11-2003 Sex-linked recessive lethal test for fruit flies
- GB/T 10613-1989 Round and square perforation plate screens--Thickness of 3 mm and above
- GB/T 3978-1994 Standard lighting objects and lighting observation conditions
- GB/T 14174-2012 Large caliber liquid nitrogen container
- GB/T 2677.8-1994 Determination of acid-insoluble lignin content in papermaking raw materials
- GB/T 13191-2009 Information and documentation-library statistics
- GB 16174.1-1996 Cardiac pacemakers Part 1: Implantable cardiac pacemakers
- GB/T 5009.129-2003 Determination of ethoxyquin residues in fruits
- JB/T 7020.2-1993 Brake arm disc brake pad
- GB/T 8190.2-1999 Emission measurement for reciprocating internal combustion engines Part 2: Field measurement of gaseous and particulate emissions
- GB 30000.29-2013 Rules for classification and labelling of chemicals—Part 29:Hazardous to the ozone layer
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com