GB 12972.2-1991 Mining rubber sheathed flexible cables Part 2: Coal shearer flexible cables with rated voltage 0.66/1.14 kV and below
time:
1991-06-06 16:00:00
- GB 12972.2-1991
- Abolished
Standard ID:
GB 12972.2-1991
Standard Name:
Mining rubber sheathed flexible cables Part 2: Coal shearer flexible cables with rated voltage 0.66/1.14 kV and below
Chinese Name:
矿用橡套软电缆 第2部分:额定电压0. 66/1.14 kV及以下采煤机软电缆
Standard category:
National Standard (GB)
-
Date of Release:
1991-06-06 -
Date of Implementation:
1992-03-01 -
Date of Expiration:
2009-04-01
Standard ICS number:
Electrical Engineering>>Wires and Cables>>29.060.20 CablesChina Standard Classification Number:
Electrician>>Electrical Materials and General Parts>>K13 Cable and Accessories
alternative situation:
Replaced GB 1170-1974; replaced by GB/T 12972.2-2008
Release date:
1991-06-06Review date:
2004-10-14Drafter:
Liu Fenglin, Tan Shengyan, Yang YanDrafting Organization:
Shanghai Cable Research Institute, Fushun Branch of China Coal Research Institute and other unitsFocal point Organization:
National Technical Committee for Standardization of Wires and CablesProposing Organization:
Ministry of Mechanical and Electronic Industry of the People's Republic of ChinaPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
China Electrical Equipment Industry Association
Skip to download
Summary:
This standard specifies the product varieties, technical requirements, test methods and inspection rules for coal shearer cables with rated voltages of 0.66/1.14kV and below. This standard applies to copper core rubber insulated rubber sheathed flexible cables for coal shearers and similar equipment with a rated voltage of 0.66/1.14kV and below. GB 12972.2-1991 Mining rubber sheathed flexible cables Part 2: Coal shearer flexible cables with rated voltage 0.66/1.14 kV and below GB12972.2-1991 Standard download and decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Rubber sheathed flexible cables for mining
Part 2: Coal shearer flexible cables with rated voltage 0.66/1.14kV and below
Flexiblerubber-sheathed cablesforminingpurposesPart 2:Flexible coalcutter cables for ratedvoltagesupto0.66/1.14kv
1 Subject content and scope of application
GB12972.2—91
Replaces GB1170-74
This standard specifies the rated voltage Product varieties, technical requirements, test methods and inspection rules for coal shearer cables 0.66/1.14kV and below.
This standard applies to copper core rubber insulated rubber sheathed flexible cables with a rated voltage U/U of 0.66/1.14kV and below for coal shearers and similar equipment.
This standard should be used together with GB12972.1. 2 Usage characteristics
2.1 Rated voltage U./U are 0.38/0.66kV and 0.66/1.14kV respectively. 2.2 The long-term allowable operating temperature of cable conductors is 65°C. 2.3 The minimum bending radius of the cable is 6 times the cable diameter. 2.4 Yellow-sheathed cables must not be exposed to sunlight for a long time. 3 model
3.1 cable model is shown in Table 1.
UC-0.38/0.66
UCP-0.38/0.66
UCP-0.66/1.14
Name|| tt||Weighing
Coal shearer rubber sheathed flexible cable
Coal shearer shielded rubber sheathed flexible cable
Coal shearer shielded rubber sheathed flexible cable
3.2 cable type Figure 1.
State Bureau of Technical Supervision 1991-06-06 Approval Table 1
Purpose
Power connection for coal shearers and similar equipment with a rated voltage of 0.38/0.66kV Power supply connection for coal shearers and similar equipment with a rated voltage of 0.38/0.66kV Power supply connection for coal shearers and similar equipment with a rated voltage of 0.66/1.14kV 1992-03-01 Implementation
4 specificationsbzxZ.net
GB 12972.2-91
Figure 1
1-power core conductor; 2-ground wire Core conductor; 3—control line core conductor; 4—insulation; 5—insulation shielding; 6—outer sheath cable specifications should comply with Table 2a and Table 2b. Table 2a
Power wire core
Number of cores |Power core
Ground core
Control core
number of cores×nominal cross-section of conductor, mm2
power core
3×35||tt| |3×50
5 technical requirements
ground core
1 ×10
Control core
Power core
Absolute||tt| |edge
nominal thickness
5.1 The technical requirements of the cable should comply with Table 3 and Table 4 regulations. 5.2 Conductor
Sheath mark
Weighing thickness
Table 2b|| tt||Sheath mark
Weighing thickness
Cable outer diameter
UC-0.38/0.66
minimum
maximum
35.1| |tt||42.0
UCP-0.38/0.66
minimum
34.7||tt| |41.3
Cable outer diameter
UCP-0.66/1.14
Minimum value
Maximum
GB12972.2-—91
5.2.1 The single wires in the conductor should be tinned, and the surface of the conductor can be covered with an isolation layer. Note: Discoloration or brittleness of the isolation layer after vulcanization will not be assessed. 5.3 Insulation
5.3.1 The insulation of power wire core and control wire core should comply with the XJ-00A regulations in GB7594.2. 5.3.2 If the ground core of UC-0.38/0.66 type cable has an insulating coating, it shall comply with the provisions of XJ-00A in GB7594.2. 5.3.3 The insulation shield adopts the Class A structure in Table 5 of GB12972.1. 5.4 Cable core
5.4.1 The position of the control wire core shall comply with the provisions of Article 7.2b of GB12972.1. 5.4.2 The position of the ground core complies with the provisions of Article 7.4c of GB12972.1. 5.4.3 The twisted pitch diameter ratio of the cable core should not be greater than 10. 5.5 Sheath
5.5.1 If the cable has an inner sheath, the rubber sheath should not be lower than the XH-02A specification in GB7594.6 . 5.5.2 The rubber of the outer sheath should comply with the XH-03A requirements in GB7594.7, but the tear strength should not be less than 7.5N/mm. Table 3
Nominal cross-section of conductor, rm2
Power core 50
70||tt| |95
Control wire core
Test and inspection rules
Products are tested according to Table 4.
Serial number
1.6|| tt||2
Project name
Structural size
Conductor
Insulation thickness
Shielding
Cable Core
Sheath thickness
Cable outer diameter
Cable performance
Conductor resistance
Table 4
Technical requirements
Insulation resistance at 20C, M·km minimum value
80||tt| |50
Test type
GB12972.1 Article 4.1 and this standard Article 5.2 GB12972.1 Article 5.2 and this standard Table 2a and Table 2b this standard Article 5.3.3||tt ||GB12972.1 Article 7 and this standard Article 5.4 GB12972.1 Article 8 and this standard Table 2a and Table 2b this standard Table 2a and Table 2b
GB12972.1 Table 1
Test method
Visual inspection
Hinging visual inspection
Serial number||tt ||2.2
Project name
Insulation resistance
Transition resistance
Power frequency AC voltage
Test| |tt||Burning test
Mechanical impact test
Extrusion test
Bending test
Insulation physical machinery
Performance
Sheath Physical machinery
Performance
Identification mark
Delivery length
Table 3 of this standard
GB 12972.2-91
Continued Table 4| |tt||Technical requirements
GB12972.1 Article 11.4
(not applicable to UC-0.38/0.66)
GB12972.1 Table 8
GB12972.1 Article 11.6
16~35mm. 2 times
50~95mm 3 times
UC-0.38/0.66 and UCP-0.38/0.66...30kNUCP-0.66/1.14 .40kN
18000 times conductor continuous
Article 5.3 of this standard
Article 5.5 of this standard
GB12972.1 Article 10
GB12972.1 Article 11.12
Note: St means periodic testing, which should be conducted at least once a year. Additional notes:
This standard is proposed by the Ministry of Mechanical and Electronics Industry of the People's Republic of China. This standard is under the jurisdiction of the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry. Test type
Test method
GB3048.5
GB12972.1 Appendix D
GB12666.2
GB12972.1 Appendix A
GB12972.1 Appendix B| | tt | The Institute, Fushun Branch of the General Institute of Coal Science and Technology and other units are responsible for drafting. The main drafters of this standard are Liu Fenglin, Tan Shengmin, and Yang Yan.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Rubber sheathed flexible cables for mining
Part 2: Coal shearer flexible cables with rated voltage 0.66/1.14kV and below
Flexiblerubber-sheathed cablesforminingpurposesPart 2:Flexible coalcutter cables for ratedvoltagesupto0.66/1.14kv
1 Subject content and scope of application
GB12972.2—91
Replaces GB1170-74
This standard specifies the rated voltage Product varieties, technical requirements, test methods and inspection rules for coal shearer cables 0.66/1.14kV and below.
This standard applies to copper core rubber insulated rubber sheathed flexible cables with a rated voltage U/U of 0.66/1.14kV and below for coal shearers and similar equipment.
This standard should be used together with GB12972.1. 2 Usage characteristics
2.1 Rated voltage U./U are 0.38/0.66kV and 0.66/1.14kV respectively. 2.2 The long-term allowable operating temperature of cable conductors is 65°C. 2.3 The minimum bending radius of the cable is 6 times the cable diameter. 2.4 Yellow-sheathed cables must not be exposed to sunlight for a long time. 3 model
3.1 cable model is shown in Table 1.
UC-0.38/0.66
UCP-0.38/0.66
UCP-0.66/1.14
Name|| tt||Weighing
Coal shearer rubber sheathed flexible cable
Coal shearer shielded rubber sheathed flexible cable
Coal shearer shielded rubber sheathed flexible cable
3.2 cable type Figure 1.
State Bureau of Technical Supervision 1991-06-06 Approval Table 1
Purpose
Power connection for coal shearers and similar equipment with a rated voltage of 0.38/0.66kV Power supply connection for coal shearers and similar equipment with a rated voltage of 0.38/0.66kV Power supply connection for coal shearers and similar equipment with a rated voltage of 0.66/1.14kV 1992-03-01 Implementation
4 specificationsbzxZ.net
GB 12972.2-91
Figure 1
1-power core conductor; 2-ground wire Core conductor; 3—control line core conductor; 4—insulation; 5—insulation shielding; 6—outer sheath cable specifications should comply with Table 2a and Table 2b. Table 2a
Power wire core
Number of cores |Power core
Ground core
Control core
number of cores×nominal cross-section of conductor, mm2
power core
3×35||tt| |3×50
5 technical requirements
ground core
1 ×10
Control core
Power core
Absolute||tt| |edge
nominal thickness
5.1 The technical requirements of the cable should comply with Table 3 and Table 4 regulations. 5.2 Conductor
Sheath mark
Weighing thickness
Table 2b|| tt||Sheath mark
Weighing thickness
Cable outer diameter
UC-0.38/0.66
minimum
maximum
35.1| |tt||42.0
UCP-0.38/0.66
minimum
34.7||tt| |41.3
Cable outer diameter
UCP-0.66/1.14
Minimum value
Maximum
GB12972.2-—91
5.2.1 The single wires in the conductor should be tinned, and the surface of the conductor can be covered with an isolation layer. Note: Discoloration or brittleness of the isolation layer after vulcanization will not be assessed. 5.3 Insulation
5.3.1 The insulation of power wire core and control wire core should comply with the XJ-00A regulations in GB7594.2. 5.3.2 If the ground core of UC-0.38/0.66 type cable has an insulating coating, it shall comply with the provisions of XJ-00A in GB7594.2. 5.3.3 The insulation shield adopts the Class A structure in Table 5 of GB12972.1. 5.4 Cable core
5.4.1 The position of the control wire core shall comply with the provisions of Article 7.2b of GB12972.1. 5.4.2 The position of the ground core complies with the provisions of Article 7.4c of GB12972.1. 5.4.3 The twisted pitch diameter ratio of the cable core should not be greater than 10. 5.5 Sheath
5.5.1 If the cable has an inner sheath, the rubber sheath should not be lower than the XH-02A specification in GB7594.6 . 5.5.2 The rubber of the outer sheath should comply with the XH-03A requirements in GB7594.7, but the tear strength should not be less than 7.5N/mm. Table 3
Nominal cross-section of conductor, rm2
Power core 50
70||tt| |95
Control wire core
Test and inspection rules
Products are tested according to Table 4.
Serial number
1.6|| tt||2
Project name
Structural size
Conductor
Insulation thickness
Shielding
Cable Core
Sheath thickness
Cable outer diameter
Cable performance
Conductor resistance
Table 4
Technical requirements
Insulation resistance at 20C, M·km minimum value
80||tt| |50
Test type
GB12972.1 Article 4.1 and this standard Article 5.2 GB12972.1 Article 5.2 and this standard Table 2a and Table 2b this standard Article 5.3.3||tt ||GB12972.1 Article 7 and this standard Article 5.4 GB12972.1 Article 8 and this standard Table 2a and Table 2b this standard Table 2a and Table 2b
GB12972.1 Table 1
Test method
Visual inspection
Hinging visual inspection
Serial number||tt ||2.2
Project name
Insulation resistance
Transition resistance
Power frequency AC voltage
Test| |tt||Burning test
Mechanical impact test
Extrusion test
Bending test
Insulation physical machinery
Performance
Sheath Physical machinery
Performance
Identification mark
Delivery length
Table 3 of this standard
GB 12972.2-91
Continued Table 4| |tt||Technical requirements
GB12972.1 Article 11.4
(not applicable to UC-0.38/0.66)
GB12972.1 Table 8
GB12972.1 Article 11.6
16~35mm. 2 times
50~95mm 3 times
UC-0.38/0.66 and UCP-0.38/0.66...30kNUCP-0.66/1.14 .40kN
18000 times conductor continuous
Article 5.3 of this standard
Article 5.5 of this standard
GB12972.1 Article 10
GB12972.1 Article 11.12
Note: St means periodic testing, which should be conducted at least once a year. Additional notes:
This standard is proposed by the Ministry of Mechanical and Electronics Industry of the People's Republic of China. This standard is under the jurisdiction of the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry. Test type
Test method
GB3048.5
GB12972.1 Appendix D
GB12666.2
GB12972.1 Appendix A
GB12972.1 Appendix B| | tt | The Institute, Fushun Branch of the General Institute of Coal Science and Technology and other units are responsible for drafting. The main drafters of this standard are Liu Fenglin, Tan Shengmin, and Yang Yan.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB 1795-1993 Jasmine Extract
- GB/T 3660-1983 Uniform weighted network for measuring continuous random noise in video
- GB 17918-1999 Safety regulations for dust explosion prevention in bulk grain loading and unloading systems at ports
- GB 17935-1999 Screw-type lamp holder
- GB/T 17274-1998 Series 1:Specification and testing for non-pressurized containers for dry bulk
- GB/T 3216-1989 Test methods for centrifugal pumps, mixed flow pumps, axial flow pumps and vortex pumps
- GB/T 4789.13-2003 Microbiological examination of food hygiene-Examination of Clostridium perfringens
- GB 17915-1999 Specifications for storage and preservation of corrosive goods
- QB/T 1758-2000 电池贴标机
- JJG 935-1998 Verification Regulation of γ -Ray Thickness Gauge
- JB/T 8411-1996 Impact air trigger
- GB/T 4678.5-2003 Die casting parts Part 5: Guide pins with head
- GB 16250-1996 Hygienic standard for air quality in workshops
- JB/T 10446-2004 Technical requirements for Y series 10kV three-phase asynchronous motors (frame size 450~630)
- JB/T 10320-2002 Silicon nitride heating elements for household and similar electric heating appliances
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com