GB 18555-2001 Occupational exposure limits for high frequency electromagnetic fields in the workplace
time:
2024-08-05 22:11:52
- GB 18555-2001
- in force
Standard ID:
GB 18555-2001
Standard Name:
Occupational exposure limits for high frequency electromagnetic fields in the workplace
Chinese Name:
作业场所高频电磁场职业接触限值
Standard category:
National Standard (GB)
-
Date of Release:
2001-01-02 -
Date of Implementation:
2002-05-01
Standard ICS number:
Environmental protection, health and safety >> 13.100 Occupational safety, industrial hygieneChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
void;
publishing house:
China Standards PressISBN:
155066.1-18353Publication date:
2004-04-18
Release date:
2001-12-04Review date:
2004-10-14Drafting Organization:
Zhejiang University (formerly Zhejiang Medical University)Focal point Organization:
Ministry of HealthPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the limits of electric and magnetic field strength of high-frequency electromagnetic fields in the workplace, i.e., the hygiene standards and their test methods. This standard applies to all types of operations involving high-frequency electromagnetic field radiation, but does not apply to environmental radiation and radiation for occupational therapy/diagnosis purposes. GB 18555-2001 Occupational exposure limits for high-frequency electromagnetic fields in the workplace GB18555-2001 Standard download decompression password: www.bzxz.net

Some standard content:
GB185552001
This standard is formulated for the first time based on experimental research, on-site labor hygiene survey data, and reference to relevant foreign standards. It forms a whole with the National Standard Hygiene Standard for Microwave Radiation in Workplaces (GB10436-1989) and the Hygiene Standard for Ultrahigh Frequency Radiation in Workplaces (GB10437-1989), and is used as a standard for electromagnetic radiation environment monitoring and health supervision in workplaces. This standard shall be implemented from May 1, 2002. Appendix A of this standard is the appendix of the standard.
This standard is proposed by the Ministry of Health of the People's Republic of China. The drafting unit of this standard: Zhejiang University.
The main drafters of this standard are Yao Gengdong, Jiang Huai, and Shao Binjie. This standard is entrusted to the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine for interpretation. 709
1 Scope
National Standard of the People's Republic of China
Occupational exposure limit for high frequency field in the work environmentGB18555—2001
This standard specifies the limits of electric field and magnetic field strength of high frequency electromagnetic field in the work environment, i.e., the hygiene standard and its test method. This standard is applicable to all kinds of operations involving high frequency electromagnetic field radiation, but not to environmental radiation and radiation for treatment/diagnosis purposes.
2 Definitions
This standard adopts the following definitions.
2.1 High frequency electromagnetic field High frequency field Electromagnetic field with a frequency of 100 kHz~30 MHz and a corresponding wavelength of 3 km~10 m. 3 Hygiene requirements
The electric field strength and magnetic field strength of high frequency electromagnetic field radiation allowed by the operator's operating position shall comply with the provisions listed in Table 1. Table 1 Allowable contact intensity of high-voltage electric and magnetic fields in the workplace Frequency
4 Test methodbzxz.net
Electric field strength
The test method of electromagnetic field strength at the operator's operating position is shown in Appendix A (Appendix of the standard). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on December 4, 2001 710
Magnetic field strength
No regulations
Implementation on May 1, 2002
A1 Scope of application
GB 18555—2001
Appendix A
(Appendix to the standard)
Specification for measurement of high-frequency electromagnetic fields
This specification applies to the measurement of electromagnetic field strength at the operating position of high-frequency operators, and the measurement of leakage energy of high-frequency equipment. A2 Measuring instruments
Select measuring instruments with range and frequency band coverage suitable for the objects to be tested, that is, high-frequency field strength meters with a range that can cover (10~~1000)V/m and (0.5~50)A/m, and a frequency band that can cover 100kHz~30MHz. Measuring instruments should be calibrated regularly (usually 1~2 years) by a nationally recognized metrology and testing department.
A3 Measurement position
A3.1 Field strength measurement at the operating position, usually the position equivalent to the head and chest is used as a representative: when some parts may be exposed to stronger radiation during operation, such as the position equivalent to the limbs or abdomen, additional measurements should be made. A3.2 When it is necessary to explore the main source of leakage, high-frequency equipment energy measurement should be performed, that is, measurement should be performed around the equipment (within the close range of the instrument tolerance). Generally, high-frequency equipment is shielded by a shell. When measuring equipment leakage energy, the shell must not be opened, but can only be measured from far to near within the shell. However, the target object cannot be within 5cm at the nearest. When the field strength is found to be close to the full range or the instrument alarms, it should be stopped immediately to avoid damaging the probe. The measured value is only for reference during protection. A3.3 Measurement method
A3.3.1 Hold the measuring instrument, place the detection probe at the position to be measured, and rotate the probe to the direction of the maximum reading. No one should be within 1m around the probe or other metal objects should be temporarily placed; magnetic measurement is not subject to this restriction. A3.3.2 Each measuring point is measured three times continuously. The measurement time for each measurement should not be less than 15 seconds. The maximum value of the stable state should be read. If the measurement reading fluctuates greatly, the measurement time should be appropriately extended. The average of the three values is taken as the field strength value of the point: A3.3.3 Measurement record
In addition to recording all measurement data, it should also include: measurement location (unit, factory name, workshop and specific measurement location), measurement time, measurement date (temperature, relative humidity), measurement instrument model, high-frequency equipment type and parameters, and personnel participating in the measurement. 711
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is formulated for the first time based on experimental research, on-site labor hygiene survey data, and reference to relevant foreign standards. It forms a whole with the National Standard Hygiene Standard for Microwave Radiation in Workplaces (GB10436-1989) and the Hygiene Standard for Ultrahigh Frequency Radiation in Workplaces (GB10437-1989), and is used as a standard for electromagnetic radiation environment monitoring and health supervision in workplaces. This standard shall be implemented from May 1, 2002. Appendix A of this standard is the appendix of the standard.
This standard is proposed by the Ministry of Health of the People's Republic of China. The drafting unit of this standard: Zhejiang University.
The main drafters of this standard are Yao Gengdong, Jiang Huai, and Shao Binjie. This standard is entrusted to the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine for interpretation. 709
1 Scope
National Standard of the People's Republic of China
Occupational exposure limit for high frequency field in the work environmentGB18555—2001
This standard specifies the limits of electric field and magnetic field strength of high frequency electromagnetic field in the work environment, i.e., the hygiene standard and its test method. This standard is applicable to all kinds of operations involving high frequency electromagnetic field radiation, but not to environmental radiation and radiation for treatment/diagnosis purposes.
2 Definitions
This standard adopts the following definitions.
2.1 High frequency electromagnetic field High frequency field Electromagnetic field with a frequency of 100 kHz~30 MHz and a corresponding wavelength of 3 km~10 m. 3 Hygiene requirements
The electric field strength and magnetic field strength of high frequency electromagnetic field radiation allowed by the operator's operating position shall comply with the provisions listed in Table 1. Table 1 Allowable contact intensity of high-voltage electric and magnetic fields in the workplace Frequency
4 Test methodbzxz.net
Electric field strength
The test method of electromagnetic field strength at the operator's operating position is shown in Appendix A (Appendix of the standard). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on December 4, 2001 710
Magnetic field strength
No regulations
Implementation on May 1, 2002
A1 Scope of application
GB 18555—2001
Appendix A
(Appendix to the standard)
Specification for measurement of high-frequency electromagnetic fields
This specification applies to the measurement of electromagnetic field strength at the operating position of high-frequency operators, and the measurement of leakage energy of high-frequency equipment. A2 Measuring instruments
Select measuring instruments with range and frequency band coverage suitable for the objects to be tested, that is, high-frequency field strength meters with a range that can cover (10~~1000)V/m and (0.5~50)A/m, and a frequency band that can cover 100kHz~30MHz. Measuring instruments should be calibrated regularly (usually 1~2 years) by a nationally recognized metrology and testing department.
A3 Measurement position
A3.1 Field strength measurement at the operating position, usually the position equivalent to the head and chest is used as a representative: when some parts may be exposed to stronger radiation during operation, such as the position equivalent to the limbs or abdomen, additional measurements should be made. A3.2 When it is necessary to explore the main source of leakage, high-frequency equipment energy measurement should be performed, that is, measurement should be performed around the equipment (within the close range of the instrument tolerance). Generally, high-frequency equipment is shielded by a shell. When measuring equipment leakage energy, the shell must not be opened, but can only be measured from far to near within the shell. However, the target object cannot be within 5cm at the nearest. When the field strength is found to be close to the full range or the instrument alarms, it should be stopped immediately to avoid damaging the probe. The measured value is only for reference during protection. A3.3 Measurement method
A3.3.1 Hold the measuring instrument, place the detection probe at the position to be measured, and rotate the probe to the direction of the maximum reading. No one should be within 1m around the probe or other metal objects should be temporarily placed; magnetic measurement is not subject to this restriction. A3.3.2 Each measuring point is measured three times continuously. The measurement time for each measurement should not be less than 15 seconds. The maximum value of the stable state should be read. If the measurement reading fluctuates greatly, the measurement time should be appropriately extended. The average of the three values is taken as the field strength value of the point: A3.3.3 Measurement record
In addition to recording all measurement data, it should also include: measurement location (unit, factory name, workshop and specific measurement location), measurement time, measurement date (temperature, relative humidity), measurement instrument model, high-frequency equipment type and parameters, and personnel participating in the measurement. 711
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 3516-1994 Determination of solvent extracts in rubber
- GB 50096-1999 Residential Design Code
- JB/T 7351-1994 Medium magnetic field permanent magnet roller
- GB/T 14159-1993 The evaluation rule for universal keyboard Chinese character coding input method
- GB 16487.3-1996 Imported waste environmental protection control standard wood and wood product waste
- GB/Z 19736-2005 Electronic imaging—Guidance for selection of document image compression methods
- TD/T 1005-2003 Regulations for gradation on agricultural land
- MT/T 941-2005 General technical requirements for ash fusibility tester
- HG/T 3091-2000 Rubber seals Specification for interface sealing ring materials for water supply, drainage and sewage pipes
- JB/T 8473-1996 Instrument valve group
- GBZ 3-2002 Diagnostic criteria for occupational chronic manganese poisoning
- NY/T 1156.12-2008 Guidelines for indoor bioassay tests for pesticides Fungicides Part 12: Pot method for control of late blight
- JB/T 9042-1999 Permanent magnets for mineral processing equipment
- GB/T 19029-2009 Guidelines for the selection of quality management system consultants and use of their services
- JB/T 8410-1996 Earth-moving machinery front reverse sound alarm device sound test method
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com