Shapes and dimensions of graphite electrode for emision spectrum
time:
2024-07-14 10:26:38
- SJ/Z 3206.6-1989
- in force
Standard ID:
SJ/Z 3206.6-1989
Standard Name:
Shapes and dimensions of graphite electrode for emision spectrum
Chinese Name:
发射光谱分析用石墨电极的形状和尺寸
Standard category:
Electronic Industry Standard (SJ)
-
Date of Release:
1989-02-10 -
Date of Implementation:
1989-03-01 -
Date of Expiration:
2010-01-20
China Standard Classification Number:
General>>Standardization Management and General Provisions>>A01 Technical Management
Publishing Department:
Ministry of Electronics Industry of the People's Republic of China
Skip to download
Summary:
SJ/Z 3206.6-1989 Shapes and dimensions of graphite electrodes for emission spectroscopy SJ/Z3206.6-1989 standard download decompression password: www.bzxz.net
This general rule applies to the shapes and dimensions of various graphite electrodes used in spectral analysis.
This general rule applies to the shapes and dimensions of various graphite electrodes used in spectral analysis.
Some standard content:
Guiding Technical Documents of the Ministry of Electronics Industry of the People's Republic of China Shape and size of graphite electrodes for emission spectroscopy This standard applies to the shapes and sizes of various graphite electrodes used in spectroscopy. Reference Standards
GB9259-88 Terminology of emission spectroscopy. 2 Dimensions and requirementsWww.bzxZ.net
SJ/Z3206.6—89
The dimensions and deviations of the graphite electrodes before forming used in this standard shall comply with the provisions in Table 1 Table 1 Dimensions and deviations of graphite electrodes before forming Order
Nominal size
Φ6x30
$8×30
Φ10×30
$13×30
$15×30
+0.3,-0
+2.0,-1.0
Full length bending
Not more than,%
2.2 The deviations of the spectral analysis electrodes of various shapes and sizes formed by the above electrodes shall not be greater than the provisions in Table 1.
3 Shape and size
According to different purposes of use, the electrodes are divided into two categories: counter electrodes and sample electrodes. 3.1 The counter electrode is the electrode that is opposite to the self-electrode or the supporting electrode and does not contain the analytical sample. The counter electrode is represented by the code "D".
The shape and size of the counter electrode are shown in Figure 1: Approved by the Ministry of Electronics Industry of the People's Republic of China on February 10, 1989 and implemented on March 1, 1989
SJ/Z 3206.B—88
Figure 1 The shape and size of the counter electrode
3.2 The sample electrode is also called the supporting electrode, which is used to place the analytical sample. The sample electrode is represented by the code "S". The shape and size of the sample electrode are shown in Figure 2.
Additional instructions
SJ/z3206.689
The shape and size of the sample electrode
This standard was proposed by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Zhao Changchun, Wang Jinxue and Huang Wenyu. 30±2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
GB9259-88 Terminology of emission spectroscopy. 2 Dimensions and requirementsWww.bzxZ.net
SJ/Z3206.6—89
The dimensions and deviations of the graphite electrodes before forming used in this standard shall comply with the provisions in Table 1 Table 1 Dimensions and deviations of graphite electrodes before forming Order
Nominal size
Φ6x30
$8×30
Φ10×30
$13×30
$15×30
+0.3,-0
+2.0,-1.0
Full length bending
Not more than,%
2.2 The deviations of the spectral analysis electrodes of various shapes and sizes formed by the above electrodes shall not be greater than the provisions in Table 1.
3 Shape and size
According to different purposes of use, the electrodes are divided into two categories: counter electrodes and sample electrodes. 3.1 The counter electrode is the electrode that is opposite to the self-electrode or the supporting electrode and does not contain the analytical sample. The counter electrode is represented by the code "D".
The shape and size of the counter electrode are shown in Figure 1: Approved by the Ministry of Electronics Industry of the People's Republic of China on February 10, 1989 and implemented on March 1, 1989
SJ/Z 3206.B—88
Figure 1 The shape and size of the counter electrode
3.2 The sample electrode is also called the supporting electrode, which is used to place the analytical sample. The sample electrode is represented by the code "S". The shape and size of the sample electrode are shown in Figure 2.
Additional instructions
SJ/z3206.689
The shape and size of the sample electrode
This standard was proposed by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Zhao Changchun, Wang Jinxue and Huang Wenyu. 30±2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QX/T 493-2019 Requirements for transportation and storage of rocket shell on weather modification
- JB/T 8311-1996 Claw-pole permanent magnet synchronous motor
- GB 8083-1987 Natural rubber standard rubber sampling
- YC/T 206-2006 Guide for cigarette distribution
- GB 12341-1990 1:25000, 1,50000, 1:100 000 topographic map aerial photogrammetry field specifications
- JB/T 10400.2-2004 Gearbox for off-grid wind turbine generator system Part 2: Test methods
- GB/T 15332-1994 Determination of softening point of hot melt adhesives - Ring and ball method
- GB/T 20532-2006 Standard of POS tag of contemporary Chinese for CIP
- QB/T 1419-1999 Papermaking machinery fiber separator
- JB/T 5577-2002 Method for measuring performance characteristics of transmissive projectors
- GB/T 4798.2-1996 Environmental conditions for the transportation of electrical and electronic products
- QB/T 2343.2-1997 Test method for brown sugar
- JB/T 9163.18-1999 Dimensions of round pressure plate
- QB/T 2453.2-1999 Children's beds and folding cots for domestic use Part 2: Test methods
- JB/T 7178-2002 Technical requirements for 300MW~600MW turbine generator rotor forgings
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com