JB/T 2304-2001 Electric lubrication pump device type parameters and dimensions (20MPa)
time:
2024-08-12 04:46:43
- JB/T 2304-2001
- in force
Standard ID:
JB/T 2304-2001
Standard Name:
Electric lubrication pump device type parameters and dimensions (20MPa)
Chinese Name:
电动润滑泵装置 型式参数与尺寸(20MPa)
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
2001-08-23 -
Date of Implementation:
2001-12-01
Standard ICS number:
Mechanical systems and general parts >> 21.260 Lubrication systemChina Standard Classification Number:
Machinery>>General Parts>>J21 Lubrication and Lubrication Devices
alternative situation:
JB 2304-1978
Focal point Organization:
Mechanical Industry Metallurgical Equipment Standardization Technical CommitteePublishing Department:
Mechanical Industry Metallurgical Equipment Standardization Technical Committee

Skip to download
Summary:
JB/T 2304—2001 This standard is a revision of JB/T 2304—1978 "Electric Dry Grease Station Types, Parameters and Dimensions". During the revision, the product's nominal pressure was improved and the motor power was increased. This standard specifies electric lubrication pump devices with a nominal pressure of 20MPa. This standard is applicable to electric lubrication pump devices used to supply grease to each lubrication point through a two-line distributor in the centralized lubrication system of heavy, metallurgical, mining, chemical, electric power, light industry, building materials and other equipment. This standard was first issued in April 1978 and was revised for the first time this time. JB/T 2304-2001 Electric Lubrication Pump Device Type Parameters and Dimensions (20MPa) JB/T2304-2001 Standard download decompression password: www.bzxz.net

Some standard content:
ICS21.260
Machinery Industry Standard of the People's Republic of China
JB/T2304—2001
Electric Lubrication Pump Device
Type, Specification and Dimensions ofelectric grease station (2o MPa)2001-08-23 Issued
China Machinery Industry Federation
2001-12-01 Implementation
JB/T2304—2001
This standard is a revision of JB/T23041978 "Electric Grease Station Type, Parameters and Dimensions". This standard increases the nominal pressure of the product, and according to the provisions of the existing basic and general national standards, the original standard is modified and supplemented in terms of content and format.
The main differences between this standard and JB/T23041978 are: the nominal pressure is increased from 10MPa to 20MPa; the motor power is increased.
This standard replaces JB/T23041978 from the date of implementation. This standard is proposed and managed by the Mechanical Industry Metallurgical Equipment Standardization Technical Committee. The drafting unit of this standard: Taiyuan Lubrication and Hydraulic Research Institute. The main drafters of this standard: Mao Jiping, Li Weimin, Duan Zisheng, Wang Xudong. This standard was first issued in April 1978, and this is the first revision. 1
Mechanical Industry Standard of the People's Republic of China
Electric Lubrication Pump Device
Type, specification and dimensions of electric grease station (2oMPa)
Type, specification and dimensions of electric grease station (2oMPa) 1 Scope
This standard specifies electric lubrication pump devices with a nominal pressure of 20MPa. JB/T2304-2001
Replaces JB/T2304—1978
This standard applies to electric lubrication pump devices used to supply grease to each lubrication point through a double-line distributor in the centralized lubrication system of heavy, metallurgical, mining, chemical, electric power, light industry and building materials equipment. 2 Types and dimensions
The types and dimensions of electric lubrication pump devices shall comply with the provisions of Figure 1 and Table 1. Table 1 Types and dimensions of electric lubrication pump devices Model
DRZ-L100
DRZL315
DRZ-L630
Note: The electromagnetic reversing valve has a self-recording pressure gauge interface with a connection thread of Rc3/8, which can be blocked with a screw plug if not needed. 3 Basic parameters
The cone penetration range of the grease used in the electric lubrication pump device is 250-350 (25℃, 150g) 1/10mm. The basic parameters of the electric lubrication pump device shall comply with the provisions of Table 2. Table 2 Basic parameters of the electric lubrication pump device
DRZ-L100
DRZ-L315
DRZ-L630
mL/min
Oil storage tank volume
Model approved by China Machinery Industry Federation on 2001-08-23
Y801-4-B
Y90S4-B,
Y90L-4-B
Motor|| tt||Electromagnet
2001-12-01Implementation
Add elimination mouth M33×2-6 external thread)
Re!(internal thread)
Connect to the pipe
2×R3/%
JB/T2304-2001
Figure 1DRZ type electric lubrication pump device
4Model and mark
Model indication method
According to the self-recording table
Re 3/4
Marking example
JB/T2304-2001
Main parameter: Oil supply capacity, mL/min
Pressure level: L level, 20MPa
Product name: Electric lubrication pump device
The electric lubrication pump device with a nominal pressure of 20MPa and an oil supply capacity of 100mL/min is marked as: Lubrication pump device JB/T23042001
DRZ-L100
Mechanical industry standardwww.bzxz.net
Electric lubrication pump device
Type, parameters and dimensions (20MPa)
JB/ T2304—2001
Published by the China Academy of Mechanical Science
Printed by the China Academy of Mechanical Science
(No. 2 Shouti South Road, Beijing, zip code 100044)*
Format 880×12301/16 Printing sheet 1/2
Word count 8000
First edition in November 2001
First printing in November 2001
Print run 1-500
Price 1000 yuan
No. 2001-161
Mechanical Industry Standards Service Network: http:/hvwwJB.ac.cn10
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T2304—2001
Electric Lubrication Pump Device
Type, Specification and Dimensions ofelectric grease station (2o MPa)2001-08-23 Issued
China Machinery Industry Federation
2001-12-01 Implementation
JB/T2304—2001
This standard is a revision of JB/T23041978 "Electric Grease Station Type, Parameters and Dimensions". This standard increases the nominal pressure of the product, and according to the provisions of the existing basic and general national standards, the original standard is modified and supplemented in terms of content and format.
The main differences between this standard and JB/T23041978 are: the nominal pressure is increased from 10MPa to 20MPa; the motor power is increased.
This standard replaces JB/T23041978 from the date of implementation. This standard is proposed and managed by the Mechanical Industry Metallurgical Equipment Standardization Technical Committee. The drafting unit of this standard: Taiyuan Lubrication and Hydraulic Research Institute. The main drafters of this standard: Mao Jiping, Li Weimin, Duan Zisheng, Wang Xudong. This standard was first issued in April 1978, and this is the first revision. 1
Mechanical Industry Standard of the People's Republic of China
Electric Lubrication Pump Device
Type, specification and dimensions of electric grease station (2oMPa)
Type, specification and dimensions of electric grease station (2oMPa) 1 Scope
This standard specifies electric lubrication pump devices with a nominal pressure of 20MPa. JB/T2304-2001
Replaces JB/T2304—1978
This standard applies to electric lubrication pump devices used to supply grease to each lubrication point through a double-line distributor in the centralized lubrication system of heavy, metallurgical, mining, chemical, electric power, light industry and building materials equipment. 2 Types and dimensions
The types and dimensions of electric lubrication pump devices shall comply with the provisions of Figure 1 and Table 1. Table 1 Types and dimensions of electric lubrication pump devices Model
DRZ-L100
DRZL315
DRZ-L630
Note: The electromagnetic reversing valve has a self-recording pressure gauge interface with a connection thread of Rc3/8, which can be blocked with a screw plug if not needed. 3 Basic parameters
The cone penetration range of the grease used in the electric lubrication pump device is 250-350 (25℃, 150g) 1/10mm. The basic parameters of the electric lubrication pump device shall comply with the provisions of Table 2. Table 2 Basic parameters of the electric lubrication pump device
DRZ-L100
DRZ-L315
DRZ-L630
mL/min
Oil storage tank volume
Model approved by China Machinery Industry Federation on 2001-08-23
Y801-4-B
Y90S4-B,
Y90L-4-B
Motor|| tt||Electromagnet
2001-12-01Implementation
Add elimination mouth M33×2-6 external thread)
Re!(internal thread)
Connect to the pipe
2×R3/%
JB/T2304-2001
Figure 1DRZ type electric lubrication pump device
4Model and mark
Model indication method
According to the self-recording table
Re 3/4
Marking example
JB/T2304-2001
Main parameter: Oil supply capacity, mL/min
Pressure level: L level, 20MPa
Product name: Electric lubrication pump device
The electric lubrication pump device with a nominal pressure of 20MPa and an oil supply capacity of 100mL/min is marked as: Lubrication pump device JB/T23042001
DRZ-L100
Mechanical industry standardwww.bzxz.net
Electric lubrication pump device
Type, parameters and dimensions (20MPa)
JB/ T2304—2001
Published by the China Academy of Mechanical Science
Printed by the China Academy of Mechanical Science
(No. 2 Shouti South Road, Beijing, zip code 100044)*
Format 880×12301/16 Printing sheet 1/2
Word count 8000
First edition in November 2001
First printing in November 2001
Print run 1-500
Price 1000 yuan
No. 2001-161
Mechanical Industry Standards Service Network: http:/hvwwJB.ac.cn10
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 39495-2020 Metallic and other inorganic coatings—Chromate-free chemical conversion coatings on allumion and its alloys
- GB 15146.10-2001 Safety requirements for the application of fixed neutron absorbers for nuclear criticality safety of fissile materials outside reactors
- GB/T 4251-2004 Carbide straight shank machine reamers
- HG/T 2966-1999 Industrial tripotassium hexacyanoferrate (potassium hexacyanoferrate)
- JB/T 5554-1991 Combination switch
- SJ 1.2-1987 Provision and requirements for preparation and revision of technical standards for electronic industry-Principles and procedures for regulation of standards-preparation plans
- HG/T 20636.7-1998 Procedures for the design of automatic control engineering
- JB/T 8874-2000 Technical requirements for rolling bearing seats
- GB/T 4100.2-1999 Dry pressed ceramic tiles Part 2: Stoneware tiles (water absorption 0.5% < E ≤ 3%)
- JB/T 6304-1992 Technical conditions for main special valves of steam turbines
- GB 15977-1995 Diagnostic criteria and management principles for schistosomiasis
- NY/T 435-2000 Green food fruit and vegetable chips
- GB/T 23191-2008 Bolete—King bolete
- GB/T 2851.5-1990 Die sliding guide die frame intermediate guide column die frame
- MT/T 652-1997 Test method and judgment rules for clear water performance of coal flotation machine
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com