DOCUMENT PREVIEW- Context sensitive help. Right clicking on any variable in the DRIP program displays a short description of that variable.
- Improved online help. The complete DRIP user's manual is now available and searchable online and from within the program.
- HTML analysis summary. A formatted report on the inputs used and outputs calculated in the current DRIP session is available using the File | Export Summary command. This information contained in this file is in standard HTML format and can be read and edited using standard browser applications, word processing programs, or spreadsheet software.
- Print analysis summary. A well-formatted printed report displaying the inputs used and outputs calculated in the current DRIP session is available using the File | Print Summary command.
- Improved gradation library. The importing and saving of sieve gradation analysis has been improved. The program allows descriptive file naming to save input gradations for future use.
- Additional sieve sizes. Particle sizes determined from hydrometer tests can now by used by the DRIP model.
- Improved graphing. Graphing of grain size distributions and sensitivity analysis plots has been simplified. Graphs generated by DRIP can now be imported directly into other Windows® applications or saved as JPEG files.
- Power 0.45 and semi-log plots. Sieve analyses can be viewed on either power 0.45 or semi-log plots.
2.0 ORGANIZATION OF THIS APPENDIX
This appendix is organized so that both the novice and experienced DRIP users can navigate easily through the program's many different features. The content of this manual is also available with the program as online help. In an effort to minimize repetition, topics that are identical in different parts of the program are usually only covered once in detail; when repeated, the reader is referred to previous explanations.
Getting Started
In Getting Started, the user will learn about the minimum system requirements for running DRIP 2.0 on a personal computer or network, DRIP 2.0 installation, and the usage of DRIP 2.0 to perform pavement drainage analysis and design.
General DRIP Operation
This section provides an in-depth guide on how to use DRIP 2.0, including file handling, data input, data analysis, and report generation. Operation of the DRIP plotting package—DripPlot—is also fully described.
6
Foreword
The contents of this appendix were adapted from the FHWA DRIP User's Guide (1) and are provided in support of PART 3, Chapter 1 and Appendix SS of the Design Guide. DRIP can be used to perform the necessary calculations for the hydraulic design of permeable bases and edgedrains, as well as for the design of aggregate and geotextile separator layers. This program is available in the Design Guide software under the Tools/Additional Programs menu.
Acknowledgements
Applied Research Associates, Inc., developed the original version of the microcomputer program titled "Drainage Requirements in Pavements (DRIP) Version 1.0" under a contract from the FHWA (contract No. DTFH61-95-C-00008). Mr. Robert Baumgardner of the FHWA supplied technical control for the project. The ARA principal investigator was Dr. Walter Barker, and Mr. Tim Wyatt led the development of the computer program. Dr. Jim Hall served as program manager. The program was delivered to the FHWA in September 1997.
This program was modified and enhanced by the ERES Division of ARA under FHWA Contract No. DTFH61-00-F-00199). Mr. Robert Baumgardner and Mr. Bing Wong of the FHWA supplied the technical control for the project. The ERES principal investigator was Dr. Jim Hall, and Mr. Gregg Larson implemented the program modifications. Mr. Jagannath Mallela of ARA-ERES served as the project manager. Under this contract, DRIP Version 2.0 and a revised user's guide were developed.
Incorporation of DRIP into the design guide was done at ARA-ERES under the guidance of Mr. Jagannath Mallela.
2
APPENDIX TT: DRAINAGE REQUIREMENT IN PAVEMENTS (DRIP) MICROCOMPUTER PROGRAM USER'S GUIDE
1.0 INTRODUCTION
Brief History of DRIP Development
Moisture-related pavement distresses have long been recognized as a primary contributor to premature failures and accelerated pavement deterioration. The Federal Highway Administration (FHWA) provides design guidance for drainage in its manual numbered FHWA-TS-80-224, "Highway Subdrainage Design." Under a study known as Demonstration Project No. 87, or simply "Demo 87," the FHWA Pavement Division developed a comprehensive effort to provide design guidance for handling water that infiltrated into the pavement structure from the surface. That study resulted in the production of the Participant Notebook for Demonstration Project No. 87. Engineers needed a concise and user-friendly microcomputer program that replicates the subsurface drainage design procedures in the Participant's Workbook for Demonstration Project No. 87. Also, because of the increasing use of the SI unit system, there was a need for the program to incorporate both SI and pound-inch (U.S. Customary) units.
Under a contract from the FHWA (contract No. DTFH61-95-C-00008) Applied Research Associates, Inc., developed the original version of the microcomputer program titled "Drainage Requirements in Pavements (DRIP) Version 1.0." DRIP was finalized in 1997.
In 1998, a new National Highway Institute course (NHI Course No. 131026) titled "Pavement Subsurface Drainage Design" was developed to further improve the guidance on pavement subsurface drainage design, construction, and maintenance. DRIP Version 1.0 was integrated into this course to perform hydraulic design computations. The program has since been used in the industry and has received excellent reviews.
However, several valuable suggestions were made by DRIP users to further improve the program. The suggestions mainly pertained to improving design input screen graphics, variable plot displays and outputs, and the user's manual. Certain key drainage calculations and plotting options were also suggested to enhance DRIP's technical capabilities. In addition, there was a need to upgrade the program to be compatible with the computing environments prevalent today.
Thus version 1.0 of the program was modified and enhanced by the ERES Division of ARA under FHWA Contract No. DTFH61-00-F-00199). The enhanced version 2.0 was finalized in 2000.
3
DRIP Capabilities
The salient features of DRIP are described below. Each of these features can be executed independently from within the program.
Roadway Geometry Calculations
Using this program feature, the user can compute the length and slope of the true drainage path based on the longitudinal and transverse grade of the roadway, as well as the width of the underlying base material. The user can perform these calculations for the two common roadway cross-sections commonly encountered—crowned and super elevated (uniform slope) sections.
Sieve Analysis Calculations
The effective grain sizes (D8), total and effective porosities, coefficient of uniformity and gradation, and coefficient of permeability can be computed for any user-entered gradation using this program feature. Plots of the gradations on semi-log and FHWA power 45 templates can also be obtained from this program screen.
Inflow Calculations
The amount of moisture infiltrating the pavement structure from rainfall and meltwater can be computed using this program option. The surface infiltration calculations can be performed using two different approaches—the Infiltration Ratio approach and the Crack Infiltration approach. Meltwater computations can be performed for a variety of soil types and pavement cross-section depths.
Permeable Base Design
The program offers two permeable base design options—depth-of-flow and time-to-drain. These methods allow the user to design an open-graded base that can handle the inflow entering the pavement structure.
Separator Layer Design
Using this program option, the user can design two types of separator layers—geotextile and aggregate separator layers. Based on the gradations of the proposed permeable base and the subgrade under consideration, the program also verifies whether a separation layer is required at all.
4
Edgedrain Design
Two types of edgedrains can be designed using this program option—geocomposite of fin drains and pipe edgedrains. The program calculates the edgedrain capacity and the outlet spacing required.
New Features in DRIP Version 2.0
DRIP 2.0 retains the capabilities of the earlier version of the program but makes the execution more efficient and incorporates all the new features explained in the previous section. DRIP 2.0 incorporates several significant advancements in user interface and capabilities:
- Win32 support. Fully compatible with Windows 95/98/NT.
- Normal and Expert modes. Normal mode warns users of potential errors during input and offers suggestions on proper program use. Expert mode suppresses these warnings, allowing experienced users of program the ability to edit data more quickly, without continually acknowledging warning screens.
- Tabbed property pages. The individual data input and analysis screens employed in DRIP Version 1.0 have been updated/improved and are now displayed using a property page format. This new format allows a more intuitive navigation through the various program screens. Each property page can be accessed by means of the tabs displayed continually along the top of the DRIP client area.
- Analysis type selection. The DRIP program allows the user to select the type of roadway geometry, inflow calculation method, permeable base analysis type, separator layer analysis type, and edgedrain type. The selections available under each of these categories are usually located in the upper left corner of the respective property page in the form of radio buttons. By making the appropriate selection, the user can customize the analysis performed on each property page. For example, to perform time-to-drain design of permeable bases, the user should select the "Time to Drain" radio button on the Permeable Base property page. The program then configures the page to display appropriate inputs and outputs for this analysis.
- Hyper-linked input data fields. In the DRIP program, certain variables appear on multiple property pages. The hyper-linking feature is aimed at preventing the novice user from inadvertently entering different values for the same DRIP variable on different property pages. By clicking the left mouse button on a hyper-linked variable (identified by an underline beneath it), the program transports the user to a property page where this variable should most logically be configured.
- Improved graphics. The graphics that illustrate drainage input variables have been improved.
- Summary screen. A linked summary list is now present on the left side of the DRIP client window. This list allows the user to get an update on the status of the current DRIP session.
5
- Context sensitive help. Right clicking on any variable in the DRIP program displays a short description of that variable.
- Improved online help. The complete DRIP user's manual is now available and searchable online and from within the program.
- HTML analysis summary. A formatted report on the inputs used and outputs calculated in the current DRIP session is available using the File | Export Summary command. This information contained in this file is in standard HTML format and can be read and edited using standard browser applications, word processing programs, or spreadsheet software.
- Print analysis summary. A well-formatted printed report displaying the inputs used and outputs calculated in the current DRIP session is available using the File | Print Summary command.
- Improved gradation library. The importing and saving of sieve gradation analysis has been improved. The program allows descriptive file naming to save input gradations for future use.
- Additional sieve sizes. Particle sizes determined from hydrometer tests can now by used by the DRIP model.
- Improved graphing. Graphing of grain size distributions and sensitivity analysis plots has been simplified. Graphs generated by DRIP can now be imported directly into other Windows® applications or saved as JPEG files.
- Power 0.45 and semi-log plots. Sieve analyses can be viewed on either power 0.45 or semi-log plots.
2.0 ORGANIZATION OF THIS APPENDIX
This appendix is organized so that both the novice and experienced DRIP users can navigate easily through the program's many different features. The content of this manual is also available with the program as online help. In an effort to minimize repetition, topics that are identical in different parts of the program are usually only covered once in detail; when repeated, the reader is referred to previous explanations.
Getting Started
In Getting Started, the user will learn about the minimum system requirements for running DRIP 2.0 on a personal computer or network, DRIP 2.0 installation, and the usage of DRIP 2.0 to perform pavement drainage analysis and design.
General DRIP Operation
This section provides an in-depth guide on how to use DRIP 2.0, including file handling, data input, data analysis, and report generation. Operation of the DRIP plotting package—DripPlot—is also fully described.