DOCUMENT PREVIEWDefinitions
This is an abbreviated list of definitions for words or terms particularly relevant to this Approved Document. The definitions for any other italicised words may be found in the New Zealand Building Code Handbook.
Amend 1 Jul 2001
Illuminance The luminous flux falling onto a unit area of surface.
Amend 1 Jul 2001
Reflectance The ratio of the flux reflected from a surface to the flux incident on it.
6
Status of Compliance Documents
Compliance Documents are prepared by the Department of Building and Housing in accordance with section 22 of the Building Act 2004. A Compliance Document is for use in establishing compliance with the New Zealand Building Code.
A person who complies with a Compliance Document will be treated as having complied with the provisions of the Building Code to which the Compliance Document relates. However, a Compliance Document is only one method of complying with the Building Code. There may be alternative ways to comply.
Users should make themselves familiar with the preface to the New Zealand Building Code Handbook, which describes the status of Compliance Documents and explains alternative methods of achieving compliance.
Defined words (italicised in the text) and classified uses are explained in Clauses A1 of the Building Code and in the Definitions at the start of this Compliance Document.
| Date | Alterations | |
|---|---|---|
| First published | July 1992 | |
| Amendment 1 | 1 July 2001 | p. 2, Document History, Status p. 9, Definitions |
| Note: Page numbers relate to the document at the time of Amendment and may not match page numbers in current document. | ||
Document Status
The most recent version of this document, as detailed in the Document History, is approved by the Chief Executive of the Department of Building and Housing. It is effective from 1 July 2001 and supersedes all previous versions of this document.
People using this Compliance Document should check for amendments on a regular basis. The Department of Building and Housing may amend any part of any Compliance Document at any time. Up-to-date versions of Compliance Documents are available from www.dbh.govt.nz
2
New Zealand Building Code Clause G8 Artificial Light
This Clause has been extracted from the New Zealand Building Code contained in the First Schedule of the Building Regulations 1992.
| 1992/150 | Building Regulations 1992 | 65 |
FIRST SCHEDULE—continued
Clause G8—ARTIFICIAL LIGHT
|
Provisions OBJECTIVE G8.1 The objective of this provision is to safeguard people from injury due to lack of adequate lighting. FUNCTIONAL REQUIREMENT G8.2 Spaces within buildings used by people, shall be provided with adequate artificial lighting which, when activated in the absence of sufficient natural light, will enable safe movement. PERFORMANCE G8.3 Illuminance at floor level shall be no less than 20 lux. |
Limits on application Requirement G8.2 shall apply to: (a) All exitways in Multi-unit Dwellings, Group Dwellings and Communal Residential, Communal Non-residential, Commercial and Industrial buildings, (b) All access routes except those in Outbuildings and Ancillary buildings, and (c) All common spaces within Multi-unit Dwellings, Group Dwellings, and Communal Residential and Communal Non-residential buildings. Performance G8.3 shall not apply in emergencies, for which Illuminance requirements are given in Clause F6 “Lighting for Emergency”. |
3
Contents
| Page | |
|---|---|
| References | 7 |
| Definitions | 9 |
| Verification Method G8/VM1 | 11 |
1.0 Illuminance |
11 |
| Acceptable Solution G8/AS1 | 13 |
1.0 Illuminance |
13 |
| Index | 15 |
4
References
For the purposes of New Zealand Building Code compliance, referenced documents shall be deemed to include any amendments issued prior to the date of the Approved Document as displayed at the foot of the page on which the references are listed.
|
Standards Association of New Zealand NZS 6703: 1984 Code of practice for interior lighting design |
Where quoted VM1 1.0.1 |
5
Definitions
This is an abbreviated list of definitions for words or terms particularly relevant to this Approved Document. The definitions for any other italicised words may be found in the New Zealand Building Code Handbook.
Amend 1 Jul 2001
Illuminance The luminous flux falling onto a unit area of surface.
Amend 1 Jul 2001
Reflectance The ratio of the flux reflected from a surface to the flux incident on it.
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
clause-g8
英语 · PDF · 6 页 · 103.38 KB