DOCUMENT PREVIEWDefinitions
This is an abbreviated list of definitions for words or terms particularly relevant to this Approved Document. The definitions for any other italicised words may be found in the New Zealand Building Code Handbook.
Asbestos as defined by the Asbestos Regulations 1983 means:
a) Actinolite, amosite, chrysotile, crocidolite, fibrous anthophyllite, or tremolite; or
b) A mixture containing a mineral specified in paragraph a) of this definition; or
c) A material that is composed wholly or partly of any such mineral; or
d) A material or article that is contaminated by any such material.
Building has the meaning ascribed to it by the Building Act 1991.
Construct in relation to a building, includes to build, erect, prefabricate, and relocate; and construction has a corresponding meaning.
Hazardous Creating an unreasonable risk to people of bodily injury or deterioration of health.
Intended use of a building includes:
a) Any reasonably foreseeable occasional other use that is not incompatible with the intended use; and
b) Normal maintenance; and
c) Activities taken in response to fire or any other reasonably foreseeable emergency – but does not include any other maintenance and repairs or rebuilding.
Safety glass means a glass so treated or combined with other materials as to reduce the likelihood of injury to persons when it is cracked or broken.
6
Status of Compliance Documents
Compliance Documents are prepared by the Department of Building and Housing in accordance with section 22 of the Building Act 2004. A Compliance Document is for use in establishing compliance with the New Zealand Building Code.
A person who complies with a Compliance Document will be treated as having complied with the provisions of the Building Code to which the Compliance Document relates. However, a Compliance Document is only one method of complying with the Building Code. There may be alternative ways to comply.
Users should make themselves familiar with the preface to the New Zealand Building Code Handbook, which describes the status of Compliance Documents and explains alternative methods of achieving compliance.
Defined words (italicised in the text) and classified uses are explained in Clauses A1 of the Building Code and in the Definitions at the start of this Compliance Document.
| Date | Alterations | ||
|---|---|---|---|
| First published | July 1992 | ||
| Amendment 1 | 19 August 1994 | pp. i and ii, Document History p. v, Contents p. vi, References | p. 3, 1.1, 1.1.1, 1.2, 1.2.1, 1.3 to 1.4.3 deleted p. 4, 1.4.4 deleted p. 5, Index |
| Reprinted incorporating Amendment 1 | July 1996 | ||
| Amendment 2 | 1 December 2000 | p. ii, Document History p. vi, References | p. 3, 1.2.1 |
| Note: Page numbers relate to the document at the time of Amendment and may not match page numbers in current document. | |||
Document Status
The most recent version of this document, as detailed in the Document History, is approved by the Chief Executive of the Department of Building and Housing. It is effective from 1 December 2000 and supersedes all previous versions of this document.
People using this Compliance Document should check for amendments on a regular basis. The Department of Building and Housing may amend any part of any Compliance Document at any time. Up-to-date versions of Compliance Documents are available from www.dbh.govt.nz
New Zealand Building Code Clause F2 Hazardous Building Materials
This Clause is extracted from the New Zealand Building Code contained in the First Schedule of the Building Regulations 1992.
| 42 Building Regulations 1992 1992/150 | |
FIRST SCHEDULE—continued | |
Clause F2—HAZARDOUS BUILDING MATERIALS | |
| Provisions | Limits on application |
|---|---|
|
OBJECTIVE F2.1 The objective of this provision is to safeguard people from injury and illness caused by exposure to hazardous building materials. FUNCTIONAL REQUIREMENT F2.2 Building materials which are potentially hazardous, shall be used in ways that avoid undue risk to people. PERFORMANCE F2.3.1 The quantities of gas, liquid, radiation or solid particles emitted by materials used in the construction of buildings, shall not give rise to harmful concentrations at the surface of the material where the material is exposed, or in the atmosphere of any space. F2.3.2 Transparent panels capable of being mistaken for an unimpeded path of travel shall be marked to make them visible. F2.3.3 Glass or other brittle materials with which people are likely to come into contact shall: (a) If broken on impact, break in a way which is unlikely to cause injury, or (b) Resist a reasonably foreseeable impact without breaking, or (c) Be protected from impact. |
Performance F2.3.2 does not apply to Housing |
3
Contents
| Page | |
|---|---|
| References | 7 |
| Definitions | 9 |
| Verification Method F2/VM1 | 11 |
| Acceptable Solution F2/AS1 | 13 |
| 1.0 Glazing | 13 |
| 1.1 Human impact safety | 13 |
| 1.2 Modification to NZS 4223 | 13 |
| 2.0 Asbestos | 13 |
| Index | 15 |
Amend 1 Aug 1994
4
References
For the purposes of New Zealand Building Code compliance, referenced documents shall be deemed to include any amendments issued prior to the date of the Approved Document as displayed at the foot of the page on which the references are listed.
| Standards New New Zealand | Where quoted | ||
|---|---|---|---|
| Amends 1 and 2 | NZS 4223:- Part 3: 1999 | Glazing in buildings Human impact safety requirements | AS1 1.1.1, 1.2.1 |
| Amend 1 Aug 1994 | |||
5
Definitions
This is an abbreviated list of definitions for words or terms particularly relevant to this Approved Document. The definitions for any other italicised words may be found in the New Zealand Building Code Handbook.
Asbestos as defined by the Asbestos Regulations 1983 means:
a) Actinolite, amosite, chrysotile, crocidolite, fibrous anthophyllite, or tremolite; or
b) A mixture containing a mineral specified in paragraph a) of this definition; or
c) A material that is composed wholly or partly of any such mineral; or
d) A material or article that is contaminated by any such material.
Building has the meaning ascribed to it by the Building Act 1991.
Construct in relation to a building, includes to build, erect, prefabricate, and relocate; and construction has a corresponding meaning.
Hazardous Creating an unreasonable risk to people of bodily injury or deterioration of health.
Intended use of a building includes:
a) Any reasonably foreseeable occasional other use that is not incompatible with the intended use; and
b) Normal maintenance; and
c) Activities taken in response to fire or any other reasonably foreseeable emergency – but does not include any other maintenance and repairs or rebuilding.
Safety glass means a glass so treated or combined with other materials as to reduce the likelihood of injury to persons when it is cracked or broken.