clause-G12-water-supplies
clause-G12-water-supplies
clause-G12-water-supplies
标准信息
STANDARD INFORMATION- 标准编号
- clause-G12-water-supplies
- 所属分类
- 其他国外标准与工程资料
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 1.51 MB
· 更新:
标准简介
OVERVIEW中文简介
标准 clause-G12-water-supplies 的预览内容
English summary
Preview of standard clause-G12-water-supplies
以上为根据文件整理的内容简介。
标准内容预览
DOCUMENT PREVIEWWATER SUPPLIES
| Page | |
|---|---|
| 4.0 Location of Solar Water Heaters | 50 |
| 4.1 Location | 50 |
| 4.2 Solar orientation and inclination | 50 |
| 5.0 Installation of Solar Water Heaters | 51 |
| 5.1 Wetback water heaters | 51 |
| 5.2 Weathertightness | 52 |
| 5.3 Pipe installation | 55 |
| 5.4 Pipe insulation | 55 |
| 6.0 Structural Support for Solar Water Heaters | 56 |
| 6.1 Scope | 56 |
| 6.2 General requirements | 56 |
| 6.3 Direct fixed solar collectors parallel to the roof | 56 |
| 6.4 Elevated solar collectors parallel to the roof | 59 |
| 6.5 Collector support rails | 61 |
| 6.6 Mounting collectors at a different pitch to the roof cladding | 62 |
| 7.0 Maintenance and Durability | 64 |
| 7.1 Maintenance | 64 |
| 7.2 Durability | 64 |
| Index | 65 |
6
Status of Compliance Documents
Compliance Documents are prepared by the Department of Building and Housing in accordance with section 22 of the Building Act 2004. A Compliance Document is for use in establishing compliance with the New Zealand Building Code.
A person who complies with a Compliance Document will be treated as having complied with the provisions of the Building Code to which the Compliance Document relates. However, a Compliance Document is only one method of complying with the Building Code. There may be alternative ways to comply.
Users should make themselves familiar with the preface to the New Zealand Building Code Handbook, which describes the status of Compliance Documents and explains alternative methods of achieving compliance.
Defined words (italicised in the text) and classified uses are explained in Clause A1 of the Building Code and in the Definitions at the start of this Compliance Document.
| Date | Alterations | |||
|---|---|---|---|---|
| First published | July 1992 | |||
| Amendment 1 | September 1993 | pp. vi–viii, References p. ix, Definitions p. 15, Table 4 p. 16, 4.5.1, 4.5.3 | p. 19, 5.2.2 b) p. 22, Table 7 p. 26, Index | |
| Amendment 2 | 19 August 1994 | pp. i and ii, Document History p. v, Contents p. viii, References p. 3, 2.2.1 e) | p. 6, 2.6, 2.6.1 p. 19, 4.13.1, 4.14, 4.14.1 p. 26, 29, Index | |
| Amendment 3 | 1 December 1995 | p. ii, Document History pp. vi–viii, References | p. 5, Table 1 p. 6, 2.5.2 | |
| Second edition published July 2001 | Effective from 1 October 2001 | Document revised – Second edition issued | ||
| Amendment 4 | 6 January 2002 | pp. 3–5 Code Clause G12 | ||
| Amendment 5 | 25 February 2004 | p. 2, Document History p.7, Contents pp. 9–11 References | pp. 23-38, 3.7.1, 3.7.4, 4.1, 6.2.1, 6.3.2–6.15, Figure 13 pp. 43-45 Index | |
| Amendment 6 | 23 June 2007 | p. 2, Document History, Status pp. 9 and 11, References | p. 13, Definitions p. 15, VM1 1.0.1 | |
| Third edition published October 2007 | Effective from 1 December 2007 | Document revised – Third edition issued | G12/AS1 amended: p. 27, Table 5 p. 32, 6.5.1 p. 35, 6.9, 6.10 p. 36, 6.11.5 | p. 37, 6.14.3 p. 38, 6.15 (deleted) p. 40, 7.5.2 New Acceptable Solution G12/AS2 included |
| Note: Page numbers relate to the document at the time of Amendment and may not match page numbers in current document. | ||||
Document Status
The most recent version of this document, as detailed in the Document History, is approved by the Chief Executive of the Department of Building and Housing. It is effective from 1 December 2007 and supersedes all previous versions of this document.
People using this Compliance Document should check for amendments on a regular basis. The Department of Building and Housing may amend any part of any Compliance Document at any time. Up-to-date versions of Compliance Documents are available from www.dbh.govt.nz
2
New Zealand Building Code Clause G12 Water Supplies
The mandatory provisions for building work are contained in the New Zealand Building Code (NZBC), which comprises the First Schedule to the Building Regulations 1992. The relevant NZBC Clause for Water Supplies is G12.
Schedule Building Amendment Regulations 2001
Schedule
New clause G12 substituted in First Schedule of principal regulations
Clause G12—Water Supplies
|
Provisions Objective G12.1 The objective of this provision is to—
Functional requirement G12.2 Buildings provided with water outlets, sanitary fixtures or sanitary appliances must have safe and adequate water supplies. Performance G12.3.1 Water intended for human consumption, food preparation, utensil washing or oral hygiene must be potable. G12.3.2 A potable water supply system shall be—
G12.3.3 A non-potable water supply system used for personal hygiene shall be installed in a manner that avoids the likelihood of illness or injury being caused by the system. G12.3.4 Water pipes and outlets provided with non-potable water shall be clearly identified. |
Limits on application Objective G12.1(d) shall apply only to those buildings to which section 47A of the Act applies. |
3
Building Amendment Regulations 2001 Schedule
|
Provisions Performance–continued G12.3.5 Sanitary fixtures and sanitary appliances must be provided with hot water when intended to be used for– (a) utensil washing; and (b) personal washing, showering or bathing. G12.3.6 Where hot water is provided to sanitary fixtures and sanitary appliances, used for personal hygiene, it must be delivered at a temperature that avoids the likelihood of scalding. G12.3.7 Water supply systems must be installed in a manner that– (a) pipes water to sanitary fixtures and sanitary appliances flow rates that are adequate for the correct functioning of those fixtures and appliances under normal conditions; and (b) avoids the likelihood of leakage; and (c) allows reasonable access to components likely to need maintenance; and (d) allows the system and any backflow prevention devices to be isolated for testing and maintenance. G12.3.8 Vessels used for producing or storing hot water must be provided with safety devices that– (a) relieve excessive pressure during both normal and abnormal conditions; and (b) limit temperatures to avoid the likelihood of flash steam production in the event of rupture. G12.3.9 A hot water system must be capable of being controlled to prevent the growth of legionella bacteria. G12.3.10 Water supply taps must be accessible and usable for people with disabilities. |
Limits on application Performance G12.3.5(b) shall apply only to housing, retirement homes and early childhood centres. Performance G12.3.10 applies only to those buildings to which section 47A of the Act applies. Clerk of the Executive Council. |
4
Contents
|
|
5
WATER SUPPLIES
| Page | |
|---|---|
| 4.0 Location of Solar Water Heaters | 50 |
| 4.1 Location | 50 |
| 4.2 Solar orientation and inclination | 50 |
| 5.0 Installation of Solar Water Heaters | 51 |
| 5.1 Wetback water heaters | 51 |
| 5.2 Weathertightness | 52 |
| 5.3 Pipe installation | 55 |
| 5.4 Pipe insulation | 55 |
| 6.0 Structural Support for Solar Water Heaters | 56 |
| 6.1 Scope | 56 |
| 6.2 General requirements | 56 |
| 6.3 Direct fixed solar collectors parallel to the roof | 56 |
| 6.4 Elevated solar collectors parallel to the roof | 59 |
| 6.5 Collector support rails | 61 |
| 6.6 Mounting collectors at a different pitch to the roof cladding | 62 |
| 7.0 Maintenance and Durability | 64 |
| 7.1 Maintenance | 64 |
| 7.2 Durability | 64 |
| Index | 65 |
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
clause-G12-water-supplies