Status of Compliance Documents
Compliance Documents are prepared by the Department of Building and Housing in accordance with section 22 of the Building Act 2004. A Compliance Document is for use in establishing compliance with the New Zealand Building Code.
A person who complies with a Compliance Document will be treated as having complied with the provisions of the Building Code to which the Compliance Document relates. However, a Compliance Document is only one method of complying with the Building Code. There may be alternative ways to comply.
Users should make themselves familiar with the preface to the New Zealand Building Code Handbook, which describes the status of Compliance Documents and explains alternative methods of achieving compliance.
Defined words (italicised in the text) and classified uses are explained in Clause A1 of the Building Code and in the Definitions at the start of this Compliance Document.
| Date | Alterations | |
|---|---|---|
| First published | July 1992 | |
| Second Edition | 28 February 1998 | Document revised – Second edition issued |
| Third Edition | E2/VM1 effective from 1 July 2004 E2/AS1 effective from 1 February 2005 | |
| Amendment 1 September 2004 | E2/AS1 effective from 1 July 2005 | p. 2 Document Status |
| Reprinted incorporating Amendment 1 September 2004 | ||
| Amendment 2 | Effective from 1 July 2005 | p. 2 Document History, Document Status pp. 5-7, 9, 10 Contents pp. 13-16 References pp. 17-20 Definitions pp. 21-24 E2/VM1 pp. 25-43, 45-47, 49, 50, 55-57, 59-67, 69-89, 93-100, 102, 103, 105-107, 111-119, 121-125, 127-135, 138, 140-144, 146, 147, 149, 150, 153-155, 157, 163-169 E2/AS1 pp. 173, 174, 177, 178 Index |
| Erratum 1 | Effective from 1 December 2005 | p. 166 Table 23 |
| Amendment 3 | 21 June 2007 | pp. 3 and 4, Building Code Clause E2 |
| Amendment 4 | 1 May 2008 | p. 2 Document History, Document Status pp. 8 and 12 Contents pp. 13-14 References pp. 171-180 E2/AS2 p. 181 Index |
| Note: Page numbers relate to the document at the time of Amendment and may not match page numbers in current document. | ||
Document Status
The most recent version of this document, as detailed in the Document History, is approved by the Chief Executive of the Department of Building and Housing. It is effective from 1 May 2008 and supersedes all previous versions of this document.
People using this Compliance Document should check for amendments on a regular basis. The Department of Building and Housing may amend any part of any Compliance Document at any time. Up-to-date versions of Compliance Documents are available from www.dbh.govt.nz
2
New Zealand Building Code Clause E2 External Moisture
This Clause is extracted from the New Zealand Building Code contained in the First Schedule of the Building Regulations 1992.
SR2007/124
|
Clause E2—External moisture Provisions Objective E2.1 The objective of this provision is to safeguard people from illness or injury that could result from external moisture entering the building. Functional requirement E2.2 Buildings must be constructed to provide adequate resistance to penetration by, and the accumulation of, moisture from the outside. Performance E2.3.1 Roofs must shed precipitated moisture. In locations subject to snowfalls, roofs must also shed melted snow. E2.3.2 Roofs and exterior walls must prevent the penetration of water that could cause undue dampness, damage to building elements, or both. E2.3.3 Walls, floors, and structural elements in contact with, or in close proximity to, the ground must not absorb or transmit moisture in quantities that could cause undue dampness, damage to building elements, or both. E2.3.4 Building elements susceptible to damage must be protected from the adverse effects of moisture entering the space below suspended floors. E2.3.5 Concealed spaces and cavities in buildings must be constructed in a way that prevents external moisture being accumulated or transferred and causing condensation, fungal growth, or the degradation of building elements. |
Limits on application Requirement E2.2 does not apply to buildings (for example, certain bus shelters, and certain buildings used for horticulture or for equipment for washing motor vehicles automatically) if moisture from the outside penetrating them, or accumulating within them, or both, is unlikely to impair significantly all or any of their amenity, durability, and stability. |
3
SR2007/124
|
Provisions Performance E2.3.6 Excess moisture present at the completion of construction must be capable of being dissipated without permanent damage to building elements. E2.3.7 Building elements must be constructed in a way that makes due allowance for the following: (a) the consequences of failure; (b) the effects of uncertainties resulting from construction or from the sequence in which different aspects of construction occur; (c) variation in the properties of materials and in the characteristics of the site. |