JB/T 6326.2-1992 Chemical analysis methods for nickel-chromium and nickel-chromium-iron alloys - Determination of chromium content by ammonium persulfate oxidation capacity method
time:
2024-07-02 00:15:29
- JB/T 6326.2-1992
- Abolished
Standard ID:
JB/T 6326.2-1992
Standard Name:
Chemical analysis methods for nickel-chromium and nickel-chromium-iron alloys - Determination of chromium content by ammonium persulfate oxidation capacity method
Chinese Name:
镍铬及镍铬铁合金化学分析方法 过硫酸铵氧化容量法测定铬量
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-06-26 -
Date of Implementation:
1993-01-01 -
Date of Expiration:
2008-09-01
China Standard Classification Number:
Electrical>>Electrical Materials and General Parts>>K14 Electrical Alloy Parts
alternative situation:
Replaced by JB/T 6326.2-2008Procurement status:
neq ASTM E38-85
Drafting Organization:
Sichuan Instrument Factory No.1Focal point Organization:
Shanghai Electric Science Research Institute, Ministry of Machinery and Electronics IndustryProposing Organization:
Shanghai Electric Science Research Institute, Ministry of Machinery and Electronics IndustryPublishing Department:
Ministry of Machinery and Electronics Industry of the People's Republic of China
Skip to download
Summary:
This standard specifies the method for determining the amount of chromium in chromium and nickel-chromium-iron alloys by ammonium persulfate oxidation. This standard is applicable to the determination of chromium in nickel-chromium and nickel-chromium-iron alloys, with a determination range of 10.00% to 30.00‰. JB/T 6326.2-1992 Chemical analysis method for nickel-chromium and nickel-chromium-iron alloys Determination of chromium content by ammonium persulfate oxidation capacity method JB/T6326.2-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T6326.2-1992
Chemical analysis method for nickel-chromium and nickel-chromium-iron alloys Determination of chromium content by ammonium persulfate oxidation volumetric method
Published on June 26, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Chemical analysis method for nickel-chromium and nickel-chromium-iron alloys Determination of chromium content by ammonium persulfate oxidation volumetric method
Subject content and scope of application
This standard specifies the method for determining chromium content in nickel-chromium and nickel-chromium-iron alloys by ammonium persulfate oxidation volumetric method. JB/T6326.21992
This standard is applicable to the determination of chromium content in nickel-chromium and nickel-chromium-iron alloys, with a determination range of 10.00% to 30.00%. 2 Reference Standards
GB1467 General Principles and General Provisions for Chemical Analysis Methods of Metallurgical Products 3 Method Summary
After the sample is dissolved with acid, chromium is oxidized to hexavalent with ammonium persulfate in a sulfuric acid-phosphoric acid medium with silver nitrate as catalyst, and titrated with standard ammonium ferrous carbonate solution.
4 Reagents
4.1 Anhydrous sodium carbonate
Hydrochloric acid (density p1.19g/ml).
Nitric acid (density p1.42g/ml).
Phosphoric acid (density p1.69g/ml).
Hydrochloric acid-nitric acid mixed acid: hydrochloric acid (4.2) + nitric acid (4.3) (1+1). Sulfuric acid (1+1).
Sulfuric acid (5+95).
Silver nitrate solution (10g/L).
4.9 Ammonium persulfate solution (200g/L) prepared on the same day. 4.10
Sodium oxide solution (50g/L).
4.11 Phenyl-anthranilic acid indicator solution (2g/L): Weigh 0.2g of phenyl-anthranilic acid and place it in a 150ml beaker, add 0.2g of anhydrous sodium carbonate (4;1), add 2~3ml of water to dissolve, dilute with water to 100ml, and mix well. 4.12 Chromium standard solution: Weigh 5.6578g of standard potassium dichromate (pre-dried at 150C for 1h, placed in a desiccator, and cooled to room temperature) and place it in a 300ml beaker, dissolve with about 200ml of water, transfer to a 1000ml volumetric flask, dilute with water to the mark, and mix well. This solution contains 2.00mg of chromium in 1ml.
4.13 Preparation and calibration of ammonium ferrous sulfate standard solution. 4.13.1 Preparation: Weigh 20g of ammonium ferrous sulfate, dissolve in 1000ml sulfuric acid (4.7), and mix well. Add 5g of pure aluminum (purity greater than 99.9%). 4.13.2 Calibration: Take three 500ml conical flasks. Add 16ml of sulfuric acid (4.6) and 5ml of phosphoric acid (4.4) to each, heat and evaporate until sulfuric acid smoke appears, cool slightly, add 50ml of water, mix well, cool to room temperature, add chromium standard solution (the amount should be close to the chromium content in the sample), dilute with water to 200ml, titrate with ammonium ferrous sulfate standard solution (4.13.1) until the solution turns light yellow, add 3 drops of phenyl anthranilic acid solution (4.11), and continue titrating until the color changes from red to bright green as the end point. Read the number of milliliters of ammonium ferrous sulfate standard solution consumed. Three portions of chromium standard solution approved by the Ministry of Machinery and Electronics Industry on June 26, 1992 and implemented on January 1, 1993
JB/T6326.21992
The extreme value of the number of liters of ammonium ferrous sulfate standard solution consumed should not exceed 0.05ml, and the average value is taken. Calculate the titer of ammonium ferrous sulfate standard solution on chromium vc according to the following formula
Wherein, T-
The titer of ammonium ferrous sulfate standard solution on chromium, g/ml: the concentration of chromium standard solution, g/ml;
VThe volume of chromium standard solution transferred, ml;
V, the average volume of ammonium ferrous sulfate standard solution consumed in titration, ml. 5 Analysis stepswwW.bzxz.Net
5.1 Sample quantity
Weigh 0.2000g of sample.
5.2 Determination
5.2.1 Place the sample in a 500ml conical flask, add 10~20ml hydrochloric acid and nitric acid mixture (4.5) to dissolve at low temperature, add 16ml sulfuric acid (4.6) and 5ml phosphoric acid (4.4), heat until sulfuric acid smoke appears, remove and cool slightly. 5.2.2 Add 200ml hot water, then add 5ml silver nitrate solution (4.8) and 20ml ammonium persulfate solution (4.9), mix well, heat and boil until the solution turns red, and continue to boil for 5 minutes to decompose the ammonium persulfate completely. Add 10 ml of sodium chloride solution (4.10), boil until the red color disappears, and continue to boil for 8-10 minutes to make the silver chloride precipitate condense and the solution clear. 5.2.3 Cool to room temperature, titrate with ammonium ferrous sulfate standard solution (4.13.1) until the solution turns light yellow, add 3 drops of phenyl anthranilic acid indicator solution (4.11), and continue to titrate until the solution changes from rose red to bright green as the end point. Calculation of analysis results
Calculate the percentage of chromium according to the following formula:
Cr(%):
Where: V,-volume of ammonium ferrous sulfate standard solution consumed by the titration sample, ml; T--titration degree of ferrous sulfate on chromium by standard solution, g/ml; (2)
mSample volume, g.
Note: If the alloy contains zirconium, 1.0% zirconium is equivalent to 0.12% chromium for correction. If vanadium is contained, correction shall be made based on 1.0% vanadium being equivalent to 0.34% chromium. Allowable difference
The difference in analysis results between laboratories shall not be greater than the allowable difference listed in the following table. Table
Chromium content
10.00~18.00
>18.00~30.00
Additional notes:
This standard was proposed and coordinated by the Shanghai Electric Science Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Sichuan Instrument Factory No. 1, and the main drafters of this standard were Li Zhengrong and Fan Chunzhen. 2
Filling allowable difference
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T6326.2-1992
Chemical analysis method for nickel-chromium and nickel-chromium-iron alloys Determination of chromium content by ammonium persulfate oxidation volumetric method
Published on June 26, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Chemical analysis method for nickel-chromium and nickel-chromium-iron alloys Determination of chromium content by ammonium persulfate oxidation volumetric method
Subject content and scope of application
This standard specifies the method for determining chromium content in nickel-chromium and nickel-chromium-iron alloys by ammonium persulfate oxidation volumetric method. JB/T6326.21992
This standard is applicable to the determination of chromium content in nickel-chromium and nickel-chromium-iron alloys, with a determination range of 10.00% to 30.00%. 2 Reference Standards
GB1467 General Principles and General Provisions for Chemical Analysis Methods of Metallurgical Products 3 Method Summary
After the sample is dissolved with acid, chromium is oxidized to hexavalent with ammonium persulfate in a sulfuric acid-phosphoric acid medium with silver nitrate as catalyst, and titrated with standard ammonium ferrous carbonate solution.
4 Reagents
4.1 Anhydrous sodium carbonate
Hydrochloric acid (density p1.19g/ml).
Nitric acid (density p1.42g/ml).
Phosphoric acid (density p1.69g/ml).
Hydrochloric acid-nitric acid mixed acid: hydrochloric acid (4.2) + nitric acid (4.3) (1+1). Sulfuric acid (1+1).
Sulfuric acid (5+95).
Silver nitrate solution (10g/L).
4.9 Ammonium persulfate solution (200g/L) prepared on the same day. 4.10
Sodium oxide solution (50g/L).
4.11 Phenyl-anthranilic acid indicator solution (2g/L): Weigh 0.2g of phenyl-anthranilic acid and place it in a 150ml beaker, add 0.2g of anhydrous sodium carbonate (4;1), add 2~3ml of water to dissolve, dilute with water to 100ml, and mix well. 4.12 Chromium standard solution: Weigh 5.6578g of standard potassium dichromate (pre-dried at 150C for 1h, placed in a desiccator, and cooled to room temperature) and place it in a 300ml beaker, dissolve with about 200ml of water, transfer to a 1000ml volumetric flask, dilute with water to the mark, and mix well. This solution contains 2.00mg of chromium in 1ml.
4.13 Preparation and calibration of ammonium ferrous sulfate standard solution. 4.13.1 Preparation: Weigh 20g of ammonium ferrous sulfate, dissolve in 1000ml sulfuric acid (4.7), and mix well. Add 5g of pure aluminum (purity greater than 99.9%). 4.13.2 Calibration: Take three 500ml conical flasks. Add 16ml of sulfuric acid (4.6) and 5ml of phosphoric acid (4.4) to each, heat and evaporate until sulfuric acid smoke appears, cool slightly, add 50ml of water, mix well, cool to room temperature, add chromium standard solution (the amount should be close to the chromium content in the sample), dilute with water to 200ml, titrate with ammonium ferrous sulfate standard solution (4.13.1) until the solution turns light yellow, add 3 drops of phenyl anthranilic acid solution (4.11), and continue titrating until the color changes from red to bright green as the end point. Read the number of milliliters of ammonium ferrous sulfate standard solution consumed. Three portions of chromium standard solution approved by the Ministry of Machinery and Electronics Industry on June 26, 1992 and implemented on January 1, 1993
JB/T6326.21992
The extreme value of the number of liters of ammonium ferrous sulfate standard solution consumed should not exceed 0.05ml, and the average value is taken. Calculate the titer of ammonium ferrous sulfate standard solution on chromium vc according to the following formula
Wherein, T-
The titer of ammonium ferrous sulfate standard solution on chromium, g/ml: the concentration of chromium standard solution, g/ml;
VThe volume of chromium standard solution transferred, ml;
V, the average volume of ammonium ferrous sulfate standard solution consumed in titration, ml. 5 Analysis stepswwW.bzxz.Net
5.1 Sample quantity
Weigh 0.2000g of sample.
5.2 Determination
5.2.1 Place the sample in a 500ml conical flask, add 10~20ml hydrochloric acid and nitric acid mixture (4.5) to dissolve at low temperature, add 16ml sulfuric acid (4.6) and 5ml phosphoric acid (4.4), heat until sulfuric acid smoke appears, remove and cool slightly. 5.2.2 Add 200ml hot water, then add 5ml silver nitrate solution (4.8) and 20ml ammonium persulfate solution (4.9), mix well, heat and boil until the solution turns red, and continue to boil for 5 minutes to decompose the ammonium persulfate completely. Add 10 ml of sodium chloride solution (4.10), boil until the red color disappears, and continue to boil for 8-10 minutes to make the silver chloride precipitate condense and the solution clear. 5.2.3 Cool to room temperature, titrate with ammonium ferrous sulfate standard solution (4.13.1) until the solution turns light yellow, add 3 drops of phenyl anthranilic acid indicator solution (4.11), and continue to titrate until the solution changes from rose red to bright green as the end point. Calculation of analysis results
Calculate the percentage of chromium according to the following formula:
Cr(%):
Where: V,-volume of ammonium ferrous sulfate standard solution consumed by the titration sample, ml; T--titration degree of ferrous sulfate on chromium by standard solution, g/ml; (2)
mSample volume, g.
Note: If the alloy contains zirconium, 1.0% zirconium is equivalent to 0.12% chromium for correction. If vanadium is contained, correction shall be made based on 1.0% vanadium being equivalent to 0.34% chromium. Allowable difference
The difference in analysis results between laboratories shall not be greater than the allowable difference listed in the following table. Table
Chromium content
10.00~18.00
>18.00~30.00
Additional notes:
This standard was proposed and coordinated by the Shanghai Electric Science Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Sichuan Instrument Factory No. 1, and the main drafters of this standard were Li Zhengrong and Fan Chunzhen. 2
Filling allowable difference
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JJG 488-2008 Verification Regulation of Watch Tester
- GB 50255-1996 Specification for construction and acceptance of power converter equipment for electrical installation engineering
- GB/T 15829.3-1995 Organic flux for soft soldering
- HG 2923-1999 Food additive sodium pyrophosphate
- GB/T 15457-1995 Determination of lubricity of film and film base
- GB 16376-1996 Diagnostic criteria and management principles for byssinosis
- GB/T 8856-1988 Method for determination of crude protein in fruit and vegetable products
- QB/T 3585-1999 Mining headlight bulbs
- QX/T 13-2002 SL2-1 Rainfall Sensor
- GB/T 2506-1989 Marine lap-welded steel flange (four-position)
- GBJ 140-1990 Design specification for fire extinguisher configuration in buildings GBJ140-90
- JB 20040-2004 Knife type particle crusher
- GB/T 3170.3-1982 Determination of aluminum powder particle size - Ethanol sieve washing method
- SY 5411-1991 Cementing construction design format
- GB/T 5629.1-1985 Flared tapered thread right angle pipe fittings
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com