MT 429-1995 Flameproof low voltage cable junction box for coal mines
time:
2024-08-07 14:16:36
- MT 429-1995
- Abolished
Standard ID:
MT 429-1995
Standard Name:
Flameproof low voltage cable junction box for coal mines
Chinese Name:
煤矿用隔爆型低压电缆接线盒
Standard category:
Coal Industry Standard (MT)
-
Date of Release:
1995-10-05 -
Date of Implementation:
1995-12-01 -
Date of Expiration:
2009-01-01
China Standard Classification Number:
Electrical Engineering>>Low Voltage Electrical Appliances>>K35 Explosion-proof Electrical Appliances
alternative situation:
Replaced by MT 429-2008
Drafter:
Li Shuanghui, Chen ZaixueDrafting Organization:
Fushun Branch of China Coal Research InstituteFocal point Organization:
Explosion-proof Branch of Coal Mine Safety Standardization Technical Committee of the Ministry of Coal IndustryProposing Organization:
Coal Mine Safety Standardization Technical Committee of the Ministry of Coal IndustryPublishing Department:
Ministry of Coal Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of flameproof low-voltage cable junction boxes for coal mines. This standard applies to flameproof low-voltage cable junction boxes for coal mines (hereinafter referred to as "junction boxes"). MT 429-1995 Flameproof low-voltage cable junction boxes for coal mines MT429-1995 Standard download decompression password: www.bzxz.net

Some standard content:
Coal Industry Standard of the People's Republic of China
Flameproof low-voltage cable junction box for coal mines
1 Subject content and scope of application
MT429-1995
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of flameproof low-voltage cable junction boxes for coal mines.
This standard applies to flameproof low-voltage cable junction boxes for coal mines (hereinafter referred to as "junction boxes"). 2 Reference standards
GB 156
Rated voltage
Packaging, storage and transportation pictorial symbols
Metal tensile test method
Rated current of electrical equipment
Basic test methods for low-voltage electrical appliances
GB1410
GB 1497
Test methods for volume resistivity and surface resistivity of solid insulating materialsBasic standards for low-voltage electrical appliances
GB/T2423.4Basic environmental test procedures for electric and electronic productsTest Db: Alternating damp heat test methodGB 2900.35
Electrical terminologyExplosion-proof electrical apparatus for explosive atmospheresGB 3836.1
GB 3836. 2
General requirements for explosion-proof electrical equipment for explosive atmospheres Explosion-proof electrical equipment for explosive atmospheres Flameproof electrical equipment "d" GB/T4942.2 Protection grade of low-voltage electrical enclosures GB10111 Method for random sampling using random numbers GB11020 Test method for determining the combustion performance of solid electrical insulating materials after exposure to ignition sources JB834 Tropical low-voltage electrical appliances
JB4262 Rubber-sheathed cable entry device for explosion-proof electrical appliances 3 Product classification
3.1.1 The explosion-proof type is the mining flameproof type.
3.1.2 The cable entry device type is divided into the compression nut type and the pressure plate type. 3.7.3 According to the purpose, it is divided into the connecting cable type and the branch cable type. 3.2 Model and meaning
Approved by the Ministry of Coal Industry of the People's Republic of China on October 5, 1995 326
Download of information science and technology
Implementation on December 1, 1995
3.3 Basic parameters
MT 429-1995
Characteristic code of shell material (plastic S, steel G, cast iron T) Number of entry devices
Rated voltage (V)
Rated current (A)
Design number (represented by 1, 2, ··, 50 in sequence) Low voltage
Junction box
3.3.1 Rated voltage: AC 36, 127, 380, 660, 1140V, DC 12, 24, 36, 48V.
3.3.2 Rated current: 10, 20, 40, 63, 100, 160, 200, 315, 400, 500A. 3.3.3 Rated frequency of AC power supply: 50Hz. 3.3.4 The junction box is for long-term working.
4 Technical requirements
The product shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 4.1
The junction box shall be able to work normally under the following conditions: 4.2
Ambient air pressure 86~110kPa,
Ambient temperature -20~+40℃;
Relative air humidity is not more than 98% (at +25℃); underground coal mine with methane explosive gas mixture, without significant shaking and severe impact vibration; Pollution level: Level 3;
g. Installation category: I.
4.3 The electrical clearance and creepage distance between conductive parts of different potentials in the junction box and between conductive parts and grounding bodies such as the shell should not be less than the provisions of Table 1 after considering the correct connection of the cable. 327
Standard Search Zero Network
Rated voltage
Minimum electrical clearance
MT429--1995
Electrical clearance and creepage distance
Minimum creepage distance, mm
Note: I, Ia are groups divided according to the comparative tracking index (CTI) of the insulating material. 4.4 When the insulation of the junction box is subjected to the power frequency withstand voltage test, there should be no breakdown and flashover phenomenon. 2
The temperature rise of the terminal in the junction box should not exceed the value specified in Table 2, and the maximum temperature of its outer shell surface is 150℃. 4.5
Table 2 Limit temperature rise of terminal blockswww.bzxz.net
Material of terminal wax
Bare copper
Bare yellow pot
Tin-plated copper (or brass)
Silver-plated or nickel-plated copper (or brass)
Other metals
Temperature rise of terminal blocks, K
4.6 After the alternating damp heat test, the insulation resistance values of the junction box under different rated insulation voltages shall comply with the provisions of Table 3, and be able to withstand the power frequency withstand voltage test specified in Article 4.4 of this standard, and there shall be no rust on the flameproof surface. Table 3 Insulation resistance values
Rated insulation voltage (U.), V
Minimum insulation resistance, MQ
60U660
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Flameproof low-voltage cable junction box for coal mines
1 Subject content and scope of application
MT429-1995
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of flameproof low-voltage cable junction boxes for coal mines.
This standard applies to flameproof low-voltage cable junction boxes for coal mines (hereinafter referred to as "junction boxes"). 2 Reference standards
GB 156
Rated voltage
Packaging, storage and transportation pictorial symbols
Metal tensile test method
Rated current of electrical equipment
Basic test methods for low-voltage electrical appliances
GB1410
GB 1497
Test methods for volume resistivity and surface resistivity of solid insulating materialsBasic standards for low-voltage electrical appliances
GB/T2423.4Basic environmental test procedures for electric and electronic productsTest Db: Alternating damp heat test methodGB 2900.35
Electrical terminologyExplosion-proof electrical apparatus for explosive atmospheresGB 3836.1
GB 3836. 2
General requirements for explosion-proof electrical equipment for explosive atmospheres Explosion-proof electrical equipment for explosive atmospheres Flameproof electrical equipment "d" GB/T4942.2 Protection grade of low-voltage electrical enclosures GB10111 Method for random sampling using random numbers GB11020 Test method for determining the combustion performance of solid electrical insulating materials after exposure to ignition sources JB834 Tropical low-voltage electrical appliances
JB4262 Rubber-sheathed cable entry device for explosion-proof electrical appliances 3 Product classification
3.1.1 The explosion-proof type is the mining flameproof type.
3.1.2 The cable entry device type is divided into the compression nut type and the pressure plate type. 3.7.3 According to the purpose, it is divided into the connecting cable type and the branch cable type. 3.2 Model and meaning
Approved by the Ministry of Coal Industry of the People's Republic of China on October 5, 1995 326
Download of information science and technology
Implementation on December 1, 1995
3.3 Basic parameters
MT 429-1995
Characteristic code of shell material (plastic S, steel G, cast iron T) Number of entry devices
Rated voltage (V)
Rated current (A)
Design number (represented by 1, 2, ··, 50 in sequence) Low voltage
Junction box
3.3.1 Rated voltage: AC 36, 127, 380, 660, 1140V, DC 12, 24, 36, 48V.
3.3.2 Rated current: 10, 20, 40, 63, 100, 160, 200, 315, 400, 500A. 3.3.3 Rated frequency of AC power supply: 50Hz. 3.3.4 The junction box is for long-term working.
4 Technical requirements
The product shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 4.1
The junction box shall be able to work normally under the following conditions: 4.2
Ambient air pressure 86~110kPa,
Ambient temperature -20~+40℃;
Relative air humidity is not more than 98% (at +25℃); underground coal mine with methane explosive gas mixture, without significant shaking and severe impact vibration; Pollution level: Level 3;
g. Installation category: I.
4.3 The electrical clearance and creepage distance between conductive parts of different potentials in the junction box and between conductive parts and grounding bodies such as the shell should not be less than the provisions of Table 1 after considering the correct connection of the cable. 327
Standard Search Zero Network
Rated voltage
Minimum electrical clearance
MT429--1995
Electrical clearance and creepage distance
Minimum creepage distance, mm
Note: I, Ia are groups divided according to the comparative tracking index (CTI) of the insulating material. 4.4 When the insulation of the junction box is subjected to the power frequency withstand voltage test, there should be no breakdown and flashover phenomenon. 2
The temperature rise of the terminal in the junction box should not exceed the value specified in Table 2, and the maximum temperature of its outer shell surface is 150℃. 4.5
Table 2 Limit temperature rise of terminal blockswww.bzxz.net
Material of terminal wax
Bare copper
Bare yellow pot
Tin-plated copper (or brass)
Silver-plated or nickel-plated copper (or brass)
Other metals
Temperature rise of terminal blocks, K
4.6 After the alternating damp heat test, the insulation resistance values of the junction box under different rated insulation voltages shall comply with the provisions of Table 3, and be able to withstand the power frequency withstand voltage test specified in Article 4.4 of this standard, and there shall be no rust on the flameproof surface. Table 3 Insulation resistance values
Rated insulation voltage (U.), V
Minimum insulation resistance, MQ
60U660
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 2571-1995 Impact test method for resin castings
- JB/T 2001.49-1999 Air gate valve for water system pump station (PN=20MPa)
- GB/T 14903-1994 Test method for torsional shear strength of inorganic adhesive sleeves
- JB/T 10174-2000 Quality inspection method for shot peening of steel parts
- JB/T 10217-2000 Combined transformer
- JB/T 7357-1994 Scraper winch
- GB/T 2614-1998 Nickel-chromium-nickel-silicon thermocouple wire
- JB/T 6687-1993 12-point flange nut
- QB/T 2473-2000 External door locks
- JJG 365-1998 Verification Regulation of Electrochemical Electrode Gas Oxygen Analyser
- GB 16541-1996 Safety technical requirements for shaft cage hoisting signal systems
- HG 2263-1992 Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters
- SY/T 0601-1997 Determination of emulsified oil and dissolved oil in water
- JB/T 9568-2000 General technical requirements for relays, protection and automatic devices in power systems
- JB/T 6637-2004 Technical conditions for rolling bearing standards
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]