JB/T 7520.2-1994 Chemical analysis methods for phosphorus copper solder - Determination of silver content by silver chloride gravimetric method
time:
1994-12-09 16:00:00
- JB/T 7520.2-1994
- in force
Standard ID:
JB/T 7520.2-1994
Standard Name:
Chemical analysis methods for phosphorus copper solder - Determination of silver content by silver chloride gravimetric method
Chinese Name:
磷铜钎料化学分析方法 氯化银重量法测定银量
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1994-12-09 -
Date of Implementation:
1995-10-01
China Standard Classification Number:
Machinery>>Processing Technology>>J33 Welding and Cutting
Focal point Organization:
Harbin Welding Research InstitutePublishing Department:
Harbin Welding Research Institute
Skip to download
Summary:
This standard specifies the determination of silver content by silver chloride gravimetric method. This standard is applicable to the determination of silver content in phosphor copper brazing materials, with a determination range of 1.50% to 16.00%. JB/T 7520.2-1994 Chemical analysis method for phosphor copper brazing materials Determination of silver content by silver chloride gravimetric method JB/T7520.2-1994 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Chemical Analysis Method of Phosphor Copper Material
Determination of Silver Content by Silver Chloride Gravimetric Method
Subject Content and Scope of Application
This standard specifies the determination of silver content by silver fluoride gravimetric method. This standard is applicable to the determination of silver content in phosphor copper material, with a determination range of 1.50%~~~16.00%. 2 Method Summary
JB/T 7520.2—94
After the sample is dissolved in nitric acid, hydrochloric acid or sodium chloride is added to generate silver chloride precipitation, which is left overnight, filtered with a glass filter, and weighed after drying.
3 Reagents
3.1 Nitric acid (1+1).
3.2 Nitric acid (1+3).
3.3 Nitric acid (1+100).
3.4 Hydrochloric acid (1+9).
3.5 Sodium chloride solution (10%),
4 Analysis steps
4.1 Sample volume
Weigh more than 2.0000 samples.
4.2 Determination
4.2.1 Place the sample (4.1) in a 300ml high-type beaker, add 20mL nitric acid (3.1), cover with a watch glass, slowly heat to dissolve, rinse the cup wall and the surface with water, and continue to heat and evaporate until it is syrupy. 4.2.2 Add 20ml nitric acid (3.2) to dissolve the salts. If saws and other precipitates are precipitated, filter with slow filter paper, wash the precipitate with hot nitric acid (3.3), and discard the precipitate. Dilute the solution with water to a volume of about 150 mL. Add hydrochloric acid (3.4) or sodium chloride solution (3.5) while stirring until no more turbid silver chloride precipitate is produced. Then add a few drops in excess. Boil slowly for 5 minutes and place in a dark place for 12 hours. 4.2.3 Use a constant-weight glass filter (G4) to filter and wash the precipitate with nitric acid (3.3) several times, then wash with water. Dry the precipitate and the glass filter in an oven at 130 ± 1°C to a constant weight, cool in a desiccator, and weigh. 5
Calculation of analysis results
Calculate the percentage of silver according to the following formula:
(mi-mz) X0. 752 6
Ag(%)=
Wherein: m--
-mass of glass filter and precipitate·g;
mass of glass filter, name;
Approved by the Ministry of Machinery Industry of the People's Republic of China on December 9, 1994, 318
Implementation on October 1, 1995!
mo sample volume, g,
silver chloride conversion factor.
0. 752 6—
Allowable difference
JB/T7520.2
The difference in analysis results should not be greater than the allowable difference listed in Table 1. Table 1
Allowance
Additional Notes:
1.50~2.50wwW.bzxz.Net
This standard was proposed by Harbin Welding Research Institute of the Ministry of Machinery Industry. This standard was drafted by Harbin Welding Research Institute. The main drafters of this standard are Bai Shuyun and Lin Kegong. 94
4. 00-~6. 00
14. 00-16. 00
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Chemical Analysis Method of Phosphor Copper Material
Determination of Silver Content by Silver Chloride Gravimetric Method
Subject Content and Scope of Application
This standard specifies the determination of silver content by silver fluoride gravimetric method. This standard is applicable to the determination of silver content in phosphor copper material, with a determination range of 1.50%~~~16.00%. 2 Method Summary
JB/T 7520.2—94
After the sample is dissolved in nitric acid, hydrochloric acid or sodium chloride is added to generate silver chloride precipitation, which is left overnight, filtered with a glass filter, and weighed after drying.
3 Reagents
3.1 Nitric acid (1+1).
3.2 Nitric acid (1+3).
3.3 Nitric acid (1+100).
3.4 Hydrochloric acid (1+9).
3.5 Sodium chloride solution (10%),
4 Analysis steps
4.1 Sample volume
Weigh more than 2.0000 samples.
4.2 Determination
4.2.1 Place the sample (4.1) in a 300ml high-type beaker, add 20mL nitric acid (3.1), cover with a watch glass, slowly heat to dissolve, rinse the cup wall and the surface with water, and continue to heat and evaporate until it is syrupy. 4.2.2 Add 20ml nitric acid (3.2) to dissolve the salts. If saws and other precipitates are precipitated, filter with slow filter paper, wash the precipitate with hot nitric acid (3.3), and discard the precipitate. Dilute the solution with water to a volume of about 150 mL. Add hydrochloric acid (3.4) or sodium chloride solution (3.5) while stirring until no more turbid silver chloride precipitate is produced. Then add a few drops in excess. Boil slowly for 5 minutes and place in a dark place for 12 hours. 4.2.3 Use a constant-weight glass filter (G4) to filter and wash the precipitate with nitric acid (3.3) several times, then wash with water. Dry the precipitate and the glass filter in an oven at 130 ± 1°C to a constant weight, cool in a desiccator, and weigh. 5
Calculation of analysis results
Calculate the percentage of silver according to the following formula:
(mi-mz) X0. 752 6
Ag(%)=
Wherein: m--
-mass of glass filter and precipitate·g;
mass of glass filter, name;
Approved by the Ministry of Machinery Industry of the People's Republic of China on December 9, 1994, 318
Implementation on October 1, 1995!
mo sample volume, g,
silver chloride conversion factor.
0. 752 6—
Allowable difference
JB/T7520.2
The difference in analysis results should not be greater than the allowable difference listed in Table 1. Table 1
Allowance
Additional Notes:
1.50~2.50wwW.bzxz.Net
This standard was proposed by Harbin Welding Research Institute of the Ministry of Machinery Industry. This standard was drafted by Harbin Welding Research Institute. The main drafters of this standard are Bai Shuyun and Lin Kegong. 94
4. 00-~6. 00
14. 00-16. 00
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 2406-2002 Pressure-sensitive adhesive label paper
- HG/T 2632-1994 General test methods for photographic grade chemicals
- GB/T 13017-2018 Guidelines for preparing enterprise standard system diagram
- GB/T 8561-2001 Code of professional technical position
- JJF 1091-2002 Calibration Specification for Micrometers for Measuring Inside Dimension
- SY 5285-1991 Milling shoes and grinding shoes for well repair
- JJG 37-2005 Verification Regulation of Sine Bars
- JB/T 5615-2004 Tractor transmission gear technical conditions
- QB/T 2025-1994 Lithographic printing ink
- QB 2656-2004 Laobaigan-flavor liquor
- GB/T 3609.2-1983 Non-optical test methods for welding goggles and masks
- QB/T 1750-1993 中国画颜料(浆状)
- JB/T 8084.1-2000 Cold Chamber Die Casting Machine Accuracy
- QB/T 1553-1992 Technical requirements for corrugated paper box packaging of lamps
- JB/T 6763-1993 YA-W, YA-WF1 series outdoor, outdoor corrosion-resistant and increased safety three-phase asynchronous motors (frame size 80~280)
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com