GB/T 2833-1996 Test method for bending strength of ceramic pipes
time:
2024-08-11 14:26:14
- GB/T 2833-1996
- in force
Standard ID:
GB/T 2833-1996
Standard Name:
Test method for bending strength of ceramic pipes
Chinese Name:
陶管弯曲强度试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1996-05-15 -
Date of Implementation:
1996-12-01
Standard ICS number:
91.100.20China Standard Classification Number:
Building Materials>>Ceramics, Glass>>Q31 Building Sanitary Ceramics
alternative situation:
GB 2833-1981Procurement status:
≠BS 65-91
publishing house:
China Standards PressISBN:
155066.1-1996Publication date:
1996-12-01
Release date:
1981-12-31Review date:
2004-10-14Drafter:
Xie JunqianDrafting Organization:
Shandong Industrial Ceramics Research InstituteFocal point Organization:
National Technical Committee for Standardization of Industrial CeramicsProposing Organization:
State Bureau of Building Materials IndustryPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
China Building Materials Industry Association
Skip to download
Summary:
This standard specifies the test equipment, specimens, test procedures, result calculation and test report for the bending strength of ceramic pipes. This standard applies to the bending strength test of ceramic pipes at room temperature. GB/T 2833-1996 Test method for bending strength of ceramic pipes GB/T2833-1996 Standard download decompression password: www.bzxz.net
Some standard content:
GB/T 2833—1996
This standard adopts the British national standard BS65:1991 Sintered ceramic pipes, accessories and joints "Appendix C Bending moment resistance (BMR) test" and is revised on the basis of the original standard GB2833-81. The technical requirements that are still applicable in the original GB2833-81 are retained.
This standard replaces GB2833-81 from the date of entry into force. This standard is proposed by the State Building Materials Industry Bureau. This standard is under the jurisdiction of the National Industrial Ceramics Standardization Technical Committee. The drafting unit of this standard: Shandong Industrial Ceramics Research and Design Institute of the State Building Materials Industry Bureau. The main drafter of this standard: Jun Qian.
This standard is entrusted to Shandong Industrial Ceramics Research and Design Institute of the State Building Materials Industry Bureau for interpretation. This standard was first issued in 1981. Www.bzxZ.net
1 Scope
National Standard of the People's Republic of China
Test method for cross-bending strength of vitrified pipe
Test method for cross-bending strength of vitrified pipeGB/T2833—1996
Replaces GB2833-81
This standard specifies the test equipment, specimens, test procedures, result calculation and test report for the bending strength of vitrified pipe. This standard applies to the bending strength test of vitrified pipe at room temperature. 2 Equipment and measuring tools
2.1 Testing machine
The relative error of the indication shall not exceed ±1%. The maximum load of the specimen failure shall be within the range of 20% to 90% of the selected range, and a constant uniform loading rate can be guaranteed during the test.
2.2 Fixture
The specimen support and pressure head shall have sufficient rigidity and shall not undergo plastic deformation during the test. The shape and size of the metal blade of the support and pressure head are shown in Figure 1.
2.3 Measuring tools
—Upper loading blade, 2, 4—Rubber plate, 3 Ceramic tube; 5—Lower supporting blade? 6—Support seat Figure 1 Test device diagram
Vernier caliper, graduation value is 0.02mm.
3 Test specimen
The test specimen should be a complete pipe. The number of test specimens shall not be less than 3. Approved by the State Administration of Technical Supervision on May 15, 19966
Implemented on December 1, 1996
4 Test steps
GB/T2833--1996
4.1 Place the sample on the two lower support blades. The distance L between the center lines of the two lower support blades (see Figure 1) is the nominal length of the ceramic pipe minus 200 mm.
4.2 Place a rubber sheet with a hardness of Shore A55 ± 5 and a thickness of 10~~15mm between the upper and lower blades and the sample. 4.3 Apply the load at a uniform speed of 0.4kN/s~0.6kN/s until it fails, and read the maximum load value when the sample fails. 4.4 Use a vernier caliper to measure the inner diameter and wall thickness of the pipe at the fracture of the pipe. The measurement should be carried out in two directions at 90° to each other along the fracture surface, and the average value should be taken.
5 Calculation of results
The bending strength is calculated according to formula (1), and the result is retained to three significant figures.
Wherein: α—bending strength of the specimen, MPa; P—load when the specimen breaks, N;
L distance between the supporting blades, mm;
d—inner diameter of the specimen at the fracture. mm,
S——wall thickness of the specimen at the fracture, mm.
6 Test report
The test report should include:
Name, specification and model of the specimen:
Sample supply unit:
-Specimen number;
-Testing machine model;
-Failure load;
Single value of bending strength;
Test date and test personnel.
PL(d + 2S)
(d + 2$)4- d
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard adopts the British national standard BS65:1991 Sintered ceramic pipes, accessories and joints "Appendix C Bending moment resistance (BMR) test" and is revised on the basis of the original standard GB2833-81. The technical requirements that are still applicable in the original GB2833-81 are retained.
This standard replaces GB2833-81 from the date of entry into force. This standard is proposed by the State Building Materials Industry Bureau. This standard is under the jurisdiction of the National Industrial Ceramics Standardization Technical Committee. The drafting unit of this standard: Shandong Industrial Ceramics Research and Design Institute of the State Building Materials Industry Bureau. The main drafter of this standard: Jun Qian.
This standard is entrusted to Shandong Industrial Ceramics Research and Design Institute of the State Building Materials Industry Bureau for interpretation. This standard was first issued in 1981. Www.bzxZ.net
1 Scope
National Standard of the People's Republic of China
Test method for cross-bending strength of vitrified pipe
Test method for cross-bending strength of vitrified pipeGB/T2833—1996
Replaces GB2833-81
This standard specifies the test equipment, specimens, test procedures, result calculation and test report for the bending strength of vitrified pipe. This standard applies to the bending strength test of vitrified pipe at room temperature. 2 Equipment and measuring tools
2.1 Testing machine
The relative error of the indication shall not exceed ±1%. The maximum load of the specimen failure shall be within the range of 20% to 90% of the selected range, and a constant uniform loading rate can be guaranteed during the test.
2.2 Fixture
The specimen support and pressure head shall have sufficient rigidity and shall not undergo plastic deformation during the test. The shape and size of the metal blade of the support and pressure head are shown in Figure 1.
2.3 Measuring tools
—Upper loading blade, 2, 4—Rubber plate, 3 Ceramic tube; 5—Lower supporting blade? 6—Support seat Figure 1 Test device diagram
Vernier caliper, graduation value is 0.02mm.
3 Test specimen
The test specimen should be a complete pipe. The number of test specimens shall not be less than 3. Approved by the State Administration of Technical Supervision on May 15, 19966
Implemented on December 1, 1996
4 Test steps
GB/T2833--1996
4.1 Place the sample on the two lower support blades. The distance L between the center lines of the two lower support blades (see Figure 1) is the nominal length of the ceramic pipe minus 200 mm.
4.2 Place a rubber sheet with a hardness of Shore A55 ± 5 and a thickness of 10~~15mm between the upper and lower blades and the sample. 4.3 Apply the load at a uniform speed of 0.4kN/s~0.6kN/s until it fails, and read the maximum load value when the sample fails. 4.4 Use a vernier caliper to measure the inner diameter and wall thickness of the pipe at the fracture of the pipe. The measurement should be carried out in two directions at 90° to each other along the fracture surface, and the average value should be taken.
5 Calculation of results
The bending strength is calculated according to formula (1), and the result is retained to three significant figures.
Wherein: α—bending strength of the specimen, MPa; P—load when the specimen breaks, N;
L distance between the supporting blades, mm;
d—inner diameter of the specimen at the fracture. mm,
S——wall thickness of the specimen at the fracture, mm.
6 Test report
The test report should include:
Name, specification and model of the specimen:
Sample supply unit:
-Specimen number;
-Testing machine model;
-Failure load;
Single value of bending strength;
Test date and test personnel.
PL(d + 2S)
(d + 2$)4- d
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 12694-1990 Hygienic standards for meat processing plants
- QB/T 2538-2002 Axial flow AC ventilating fan
- JB/T 9117-1999 Metal plate offset printing machine
- JJG 943-1998 Total Suspended Particulate Sampler
- JB/T 10410-2004 Automatic backwash filter for industrial water
- JB/T 9005.3-1999 Types, hubs and bearing dimensions of cast pulleys for cranes
- JB/T 7620-1994 Compensated AC voltage stabilizer
- GB 19489-2004 General requirements for laboratory biosafety
- QB/T 1948-2004 Liuqin
- QB/T 2462.1-1999 Radiation cross-linked polyolefin plastics for wires and cables, rated voltage 0~10KV polyethylene insulation materials
- GB 19441-2004 Quarantine Specification for Highly Pathogenic Avian Influenza of Inbound and Outbound Poultry and Their Products
- JB/T 4311.5-2002 Indirect resistance furnace RJ series natural convection pit resistance furnace
- SJ 20720-1998 General specification for split-type Stirling refrigerators
- JB/T 1329-1991 Connection dimensions of steam turbine and steam turbine generator
- JB/T 9163.17-1999 Dimensions of shouldered hexagon nuts
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com