GB/T 5509-1985 Grain and oil inspection powder determination method for magnetic metal content
time:
2024-08-04 16:23:47
- GB/T 5509-1985
- Abolished
Standard ID:
GB/T 5509-1985
Standard Name:
Grain and oil inspection powder determination method for magnetic metal content
Chinese Name:
粮食、油料检验 粉类磁性金属物测定法
Standard category:
National Standard (GB)
-
Date of Release:
1985-01-01 -
Date of Implementation:
1986-07-01 -
Date of Expiration:
2009-01-20
Standard ICS number:
Food Technology >> 67.040 Food ComprehensiveChina Standard Classification Number:
Food>>Food Processing and Products>>X10 Food Processing and Products Comprehensive
alternative situation:
Replaced by GB/T 5509-2008
Release date:
1985-11-02Review date:
2004-10-14Drafting Organization:
Grain Storage and Transportation Bureau, Ministry of CommerceFocal point Organization:
National Technical Committee on Grain and Oil StandardizationPublishing Department:
National Bureau of StandardsCompetent Authority:
State Grain Administration

Skip to download
Summary:
This standard is applicable to the determination of magnetic metal content in commercial flour and grain. GB/T 5509-1985 Grain and oilseed inspection method for determination of magnetic metal content in flour and grain GB/T5509-1985 standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Inspection of grain and oilseeds
Methods for determination of magnetic metals content of flours
Inspection of grain and oilseedsMethods for determination of magnetic metals content of floursThis standard applies to the determination of magnetic metals content in commercial flours.Instruments and appliances
1.1Magnetic metal detector (electromagnet);1.2Magnet: suction force not less than 12kg, horseshoe-shaped;1.3Balance: sensitivity 0.0001g, 0.1g
1.4Crock or aluminum box, surface blood, brush, etc. 2 Operation method
2.1 Magnetic metal object measuring instrument method
GB/T5509-85
Weigh 1kg of sample from the average sample, pour it into the container on the top of the measuring instrument, turn on the power, energize the electromagnet, start the motor, adjust the flow control plate, and let the sample flow into the sample box through the elimination plate. After the sample flows out, cut off the power, cut off the magnet, brush off the magnetic metal object and put it into the surface blood. Then carry out the sample three times according to the above method, combine the magnetic metal objects in each time into the known weight of the glass (W0), rinse with carbon tetrachloride several times until the powder particles are removed, and then dry, cool, and weigh (wi).
2.2 Magnet attraction method
Weigh 1kg of the sample from the average sample, pour it on a glass plate or a smooth flat table, spread it into a rectangle with a thickness of about 0.5cm, insert the two poles into the sample with a horseshoe magnet, the front end of the magnet can be slightly raised, and the rear end is in contact with the glass plate, first move slowly from top to bottom, and then move from left to right. When the magnet passes through all the samples, use a brush to gently brush off the non-magnetic objects attached to the magnet, and brush the metal objects into (WO) of known weight. After mixing the samples, perform the above method three times
, and weigh the magnetic metal objects sucked out together (W1). 8 Result calculation
The content of magnetic metal objects is calculated according to the following formula: Magnetic metal objects (mg/kg) = (W1-W0)X1000, where: wo—weight, g;bZxz.net
W1——weight of magnetic metal objects and crucible, g. The highest content is the determination result for the double test. Note: After using the magnet, the two plates must be covered with an iron sheet about 1 cm thick to maintain the magnetism. Additional Notes:
This standard was proposed by the Ministry of Commerce of the People's Republic of China. This standard was drafted by the Grain Storage and Transportation Bureau of the Ministry of Commerce. The main drafters of this standard are Gao Xiuwu, Yang Haoran, Hao Yanxia, and Chang Guifen. Issued by the National Bureau of Standards on November 2, 1985
Implemented on July 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Inspection of grain and oilseeds
Methods for determination of magnetic metals content of flours
Inspection of grain and oilseedsMethods for determination of magnetic metals content of floursThis standard applies to the determination of magnetic metals content in commercial flours.Instruments and appliances
1.1Magnetic metal detector (electromagnet);1.2Magnet: suction force not less than 12kg, horseshoe-shaped;1.3Balance: sensitivity 0.0001g, 0.1g
1.4Crock or aluminum box, surface blood, brush, etc. 2 Operation method
2.1 Magnetic metal object measuring instrument method
GB/T5509-85
Weigh 1kg of sample from the average sample, pour it into the container on the top of the measuring instrument, turn on the power, energize the electromagnet, start the motor, adjust the flow control plate, and let the sample flow into the sample box through the elimination plate. After the sample flows out, cut off the power, cut off the magnet, brush off the magnetic metal object and put it into the surface blood. Then carry out the sample three times according to the above method, combine the magnetic metal objects in each time into the known weight of the glass (W0), rinse with carbon tetrachloride several times until the powder particles are removed, and then dry, cool, and weigh (wi).
2.2 Magnet attraction method
Weigh 1kg of the sample from the average sample, pour it on a glass plate or a smooth flat table, spread it into a rectangle with a thickness of about 0.5cm, insert the two poles into the sample with a horseshoe magnet, the front end of the magnet can be slightly raised, and the rear end is in contact with the glass plate, first move slowly from top to bottom, and then move from left to right. When the magnet passes through all the samples, use a brush to gently brush off the non-magnetic objects attached to the magnet, and brush the metal objects into (WO) of known weight. After mixing the samples, perform the above method three times
, and weigh the magnetic metal objects sucked out together (W1). 8 Result calculation
The content of magnetic metal objects is calculated according to the following formula: Magnetic metal objects (mg/kg) = (W1-W0)X1000, where: wo—weight, g;bZxz.net
W1——weight of magnetic metal objects and crucible, g. The highest content is the determination result for the double test. Note: After using the magnet, the two plates must be covered with an iron sheet about 1 cm thick to maintain the magnetism. Additional Notes:
This standard was proposed by the Ministry of Commerce of the People's Republic of China. This standard was drafted by the Grain Storage and Transportation Bureau of the Ministry of Commerce. The main drafters of this standard are Gao Xiuwu, Yang Haoran, Hao Yanxia, and Chang Guifen. Issued by the National Bureau of Standards on November 2, 1985
Implemented on July 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 4789.12-2003 Microbiological examination of food hygiene - Examination of Clostridium botulinum and botulinum toxin
- GB/T 5169.12-1999 Fire hazard test for electrical and electronic products - Test methods - Glow-wire flammability test for materials
- HG/T 2672-1995 Leveling agent O
- HG/T 2757-1996 Determination of the reactivity of phenolic resin on the B-stage conversion test plate
- JB/T 85-1994 flanged plate loose steel pipe flange
- GB/T 2429-1988 Calculation method of net calorific value of aviation fuel
- QB/T 1540-1992 Brass wire for clocks
- GB 4706.33-2003 Safety of household and similar electrical appliances Particular requirements for commercial electric deep fat fryers
- SY/T 5339-2000 Recommended practices for sand control of artificial wellbore walls
- GB/T 15389-1994 Screw
- JB/T 9160.7-1999 Dimensions of straight radial toolholders for single-spindle turret automatic lathes
- JB/T 9980-1999 Inertia vibrating table types and basic parameters
- SJ 20166-1992 Detailed specification for SF-1213 type antimony sulfide video tube
- SY/T 4099-1995 Technical specification for the design and construction of beach seawalls
- GB 16355-1996 Radiological health protection standard for X-ray diffractometers and fluorescence analyzers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]