GB 8780-1988 Hygienic standard for dimethylacetamide in workshop air
time:
2024-08-10 08:21:25
- GB 8780-1988
- in force
Standard ID:
GB 8780-1988
Standard Name:
Hygienic standard for dimethylacetamide in workshop air
Chinese Name:
车间空气中二甲基已酰胺卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1988-02-23 -
Date of Implementation:
1988-01-02
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
Release date:
1988-02-23Review date:
2004-10-14Drafting Organization:
Shanghai Institute of Labor Hygiene and Occupational DiseasesFocal point Organization:
Ministry of HealthPublishing Department:
Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard applies to all types of enterprises that produce and use dimethylacetamide. GB 8780-1988 Hygienic standard for dimethylacetamide in workshop air GB8780-1988 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Hyglenic standard for dimethylacetamide in the air or workplace
This standard applies to all types of enterprises that produce and use dimethylacetamide. 1 Hygienic requirements
The maximum allowable concentration of dimethylacetamide in the air is 10 mg/m(skin). 2 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. Approved by the Ministry of Health of the People's Republic of China on February 23, 1988 UDC661.92.013
.8:628.512
GB 8780-88
Implementation on December 1, 1988
A.1 Principle
GB 87B0
Appendix A
Gas chromatography
(Supplement)
Dimethylethylamine in air is separated by polyethylene glycol 20000 and potassium hydroxide chromatographic columns and detected by hydrogen flame ionization detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. The detection limit of this method is 5×10- (injection of 5μl liquid sample). A.2 Apparatus
A.2. 1 Syringe: 100 ml, 1ml.
A. 2.2 Microsyringe: 10 μl.
A.2.3 Gas chromatograph: hydrogen flame ionization detector. A.3 ReagentswwW.bzxz.Net
A. 3.1—Methylacetamide: chromatographic grade,
A.3.2 Polyethylene glycol 20000: chromatographic stationary liquid. A.3.3 Potassium hydroxide.
A.3.4 6201 Support: 60~80 days.
A.4 Fruit sample
Use a porous glass plate absorption tube containing 5 ml of water to extract 10~20 L of air at a speed of 1 L/min. A. 5 Analysis steps
A.5.1 Chromatographic conditions
A,5. 1. 1 Chromatographic column: 2 m long, 4 mm inner diameter, stainless steel column. A.5.1.2 Polyethylene glycol 20000 Potassium hydroxide 6201 → 5 5:100. A.5.1.3 Column temperature: 120.
A.5.1.4 Vaporization chamber temperature: 200C.
A.5.1.5 Detection chamber temperature 150℃.
A.5.1.6 Carrier gas (ammonia): 30ml/mn. A.5.2 Drawing of standard curve
Prepare with water and dilute appropriately to 1ml standard solution containing 0.0250.050.0.075mg dimethylacetamide. Inject 5ul, measure retention time and peak height, repeat 3 times for each degree, and take the average peak height. Plot the peak quotient against the content of dimethylacetamide and draw the standard curve. Retention time is a qualitative indicator. A.5.3 Chromatogram
:comA.5.4 Sample analysis
GB 8780-88
Methyl acetamide
liMethyl acetamide
Time, min
Take 5 μ sample injection, use retention time for qualitative analysis and peak height for quantitative analysis. A.5.5 Calculation
Where: x-concentration of dimethylacetamide in air, mg/mC-content of dimethylacetamide found on the standard curve; V,-converted sampling volume under standard conditions, L. Note: When the concentration of dimethylacetamide is 0.15, 0.3, and 0.6 ug, the coefficient of variation is 4.7%, 3.7%, and 3. 4% respectively. Additional notes:
This standard is proposed by the Labor Hygiene Standard Subcommittee of the National Health Standard Technical Committee. This standard was drafted by Shanghai Labor Hygiene and Occupational Diseases Research Institute. The main author of this standard is Fu Weizu. This standard is interpreted by the Labor Hygiene and Occupational Diseases Research Institute of the Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Hyglenic standard for dimethylacetamide in the air or workplace
This standard applies to all types of enterprises that produce and use dimethylacetamide. 1 Hygienic requirements
The maximum allowable concentration of dimethylacetamide in the air is 10 mg/m(skin). 2 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. Approved by the Ministry of Health of the People's Republic of China on February 23, 1988 UDC661.92.013
.8:628.512
GB 8780-88
Implementation on December 1, 1988
A.1 Principle
GB 87B0
Appendix A
Gas chromatography
(Supplement)
Dimethylethylamine in air is separated by polyethylene glycol 20000 and potassium hydroxide chromatographic columns and detected by hydrogen flame ionization detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. The detection limit of this method is 5×10- (injection of 5μl liquid sample). A.2 Apparatus
A.2. 1 Syringe: 100 ml, 1ml.
A. 2.2 Microsyringe: 10 μl.
A.2.3 Gas chromatograph: hydrogen flame ionization detector. A.3 ReagentswwW.bzxz.Net
A. 3.1—Methylacetamide: chromatographic grade,
A.3.2 Polyethylene glycol 20000: chromatographic stationary liquid. A.3.3 Potassium hydroxide.
A.3.4 6201 Support: 60~80 days.
A.4 Fruit sample
Use a porous glass plate absorption tube containing 5 ml of water to extract 10~20 L of air at a speed of 1 L/min. A. 5 Analysis steps
A.5.1 Chromatographic conditions
A,5. 1. 1 Chromatographic column: 2 m long, 4 mm inner diameter, stainless steel column. A.5.1.2 Polyethylene glycol 20000 Potassium hydroxide 6201 → 5 5:100. A.5.1.3 Column temperature: 120.
A.5.1.4 Vaporization chamber temperature: 200C.
A.5.1.5 Detection chamber temperature 150℃.
A.5.1.6 Carrier gas (ammonia): 30ml/mn. A.5.2 Drawing of standard curve
Prepare with water and dilute appropriately to 1ml standard solution containing 0.0250.050.0.075mg dimethylacetamide. Inject 5ul, measure retention time and peak height, repeat 3 times for each degree, and take the average peak height. Plot the peak quotient against the content of dimethylacetamide and draw the standard curve. Retention time is a qualitative indicator. A.5.3 Chromatogram
:comA.5.4 Sample analysis
GB 8780-88
Methyl acetamide
liMethyl acetamide
Time, min
Take 5 μ sample injection, use retention time for qualitative analysis and peak height for quantitative analysis. A.5.5 Calculation
Where: x-concentration of dimethylacetamide in air, mg/mC-content of dimethylacetamide found on the standard curve; V,-converted sampling volume under standard conditions, L. Note: When the concentration of dimethylacetamide is 0.15, 0.3, and 0.6 ug, the coefficient of variation is 4.7%, 3.7%, and 3. 4% respectively. Additional notes:
This standard is proposed by the Labor Hygiene Standard Subcommittee of the National Health Standard Technical Committee. This standard was drafted by Shanghai Labor Hygiene and Occupational Diseases Research Institute. The main author of this standard is Fu Weizu. This standard is interpreted by the Labor Hygiene and Occupational Diseases Research Institute of the Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 14926.2-2001 Detection method for Listeria monocytogenes in experimental animals
- GB/T 39464-2020 Multilingual classification and named of cross-border E-commerce trading products—Footwear
- GB/T 11457-1995 Software Engineering Terminology
- JB/T 8713-1998 Categories, types and basic parameters of mechanical parking equipment
- GB/T 23859-2009 The time measuremeut method of labor quota
- SY/T 5020-1997 Tapered cylindrical threads for drilling pumps
- JB/T 10208-2000 Graphic symbols for operating instructions of electrical discharge machining machines
- JB/T 9984.1-1999 Parameters of pass-through shot blasting machine
- GB/T 2900.59-2002 Electrical terminology - Power generation, transmission and distribution substations
- GB/T 17980.7-2000 Pesticide-Guidelines for the field efficacy trials(Ⅰ)-Acaricides against spidermite on apple
- HG/T 3688-2000 High quality flake potassium hydroxide
- GB/T 40036-2021 Translation services—Post-editing of machine translation output—Requirements
- GB/T 19662-2005 Industrial Automation System Manufacturing Message Specification Terminology
- JB/T 5000.11-1998 General technical conditions for piping of heavy machinery
- GB/T 8804.2-2003 Determination of tensile properties of thermoplastic pipes Part 2: Unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) and high impact polyvinyl chloride (PVC-HI) pipes
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com