JB/T 6870-1993 Technical requirements for rotating magnetic field flaw detectors
time:
2024-07-14 13:41:50
- JB/T 6870-1993
- Abolished
Standard ID:
JB/T 6870-1993
Standard Name:
Technical requirements for rotating magnetic field flaw detectors
Chinese Name:
旋转磁场探伤仪技术条件
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-07-09 -
Date of Implementation:
1994-01-01 -
Date of Expiration:
2006-02-01
China Standard Classification Number:
Instruments and meters>>Testing machines and nondestructive testing instruments>>N78X-ray, magnetic powder, fluorescent and other flaw detection instruments
alternative situation:
Replaced by JB/T 6870-2005
Skip to download
Summary:
JB/T 6870-1993 Technical Specifications for Rotating Magnetic Field Flaw Detectors JB/T6870-1993 Standard Download Decompression Password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Technical Conditions for Rotating Magnetic Field Flaw Detectors
Subject Content and Scope of Application
JB/T6870—93
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging, transportation and storage requirements for rotating magnetic field flaw detectors (hereinafter referred to as flaw detectors).
This standard applies to rotating magnetic field magnetic particle flaw detectors generated by cross yokes. 2 Reference standardsbzxZ.net
GB191 Packaging, storage and transportation pictorial marks
GB/T2611 General technical requirements for testing machines
GB6388 Shipping and receiving marks for transport packaging
JB/T6147 Technical requirements for testing machine packaging, packaging marks, storage and transportation ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters 3 Terms
3.1 Crossed yoke:
A magnetizing device composed of two yoke-shaped electromagnets that cross in space or cross in plane at a certain angle and are excited by two sets of alternating currents with different phases.
3.2 Effective magnetization range: The maximum magnetization area that meets the requirements of detection sensitivity. 3.3 Suction: Also known as lifting force.
The attraction between the magnetic extreme end face of the cross yoke and the flaw detection surface. Technical requirements
The flaw detector should work normally under the following environmental conditions: 4.1
Environmental temperature: 0~40℃;
Relative air humidity is not more than 80%;
The power supply voltage fluctuation shall not exceed ±10% of the rated power supply voltage; There shall be no large amount of dust, flammable or corrosive gas in the surrounding environment. The rated working voltage error of the flaw detector shall not exceed the provisions of Table 1. The phase difference between the two sets of working voltages shall be: 90°±5° or 120°±5°Table 1
Rated working voltage (V)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Technical Conditions for Rotating Magnetic Field Flaw Detectors
Subject Content and Scope of Application
JB/T6870—93
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging, transportation and storage requirements for rotating magnetic field flaw detectors (hereinafter referred to as flaw detectors).
This standard applies to rotating magnetic field magnetic particle flaw detectors generated by cross yokes. 2 Reference standardsbzxZ.net
GB191 Packaging, storage and transportation pictorial marks
GB/T2611 General technical requirements for testing machines
GB6388 Shipping and receiving marks for transport packaging
JB/T6147 Technical requirements for testing machine packaging, packaging marks, storage and transportation ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters 3 Terms
3.1 Crossed yoke:
A magnetizing device composed of two yoke-shaped electromagnets that cross in space or cross in plane at a certain angle and are excited by two sets of alternating currents with different phases.
3.2 Effective magnetization range: The maximum magnetization area that meets the requirements of detection sensitivity. 3.3 Suction: Also known as lifting force.
The attraction between the magnetic extreme end face of the cross yoke and the flaw detection surface. Technical requirements
The flaw detector should work normally under the following environmental conditions: 4.1
Environmental temperature: 0~40℃;
Relative air humidity is not more than 80%;
The power supply voltage fluctuation shall not exceed ±10% of the rated power supply voltage; There shall be no large amount of dust, flammable or corrosive gas in the surrounding environment. The rated working voltage error of the flaw detector shall not exceed the provisions of Table 1. The phase difference between the two sets of working voltages shall be: 90°±5° or 120°±5°Table 1
Rated working voltage (V)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 18926-2002 Packaging containers--Wood members
- GB/T 16469-1996 Sewing machine packing
- JB/T 1212-1999 Round bubble cap
- JB/T 8021.2-1999 Machine tool fixture parts and components - Bolt-type positioners
- SY/T 0414-1998 Technical standard for polyethylene adhesive tape anti-corrosion coating on steel pipes
- JR/T 0183-2020 Investor identification code for securities and futures industry
- QB/T 2291-1997 Machine belt buckles
- GB 4716-1993 Technical requirements and test methods for point-type heat-sensing fire detectors
- GB 4915-1996 Cement plant air pollutant emission standards
- BB/T 0058-2011 Wrapping multilayer co-extrusion overloaded membrane bags
- SB/T 10389-2004 Determination of sorbic acid in meat and meat products
- GB/T 19557.1-2004 General directives for the conduct of tests of distinctness,uniformity and stability for new varieties of plants
- HG/T 20566-1994 Chemical rotary kiln design regulations
- GB 18584-2001 Limits of harmful substances in wooden furniture for interior decoration and renovation
- QX/T 83-2019 Specifications for construction of mobile meteorological platforms
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com