JB/T 6870-1993 Technical requirements for rotating magnetic field flaw detectors
time:
2024-07-14 13:41:50
- JB/T 6870-1993
- Abolished
Standard ID:
JB/T 6870-1993
Standard Name:
Technical requirements for rotating magnetic field flaw detectors
Chinese Name:
旋转磁场探伤仪技术条件
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-07-09 -
Date of Implementation:
1994-01-01 -
Date of Expiration:
2006-02-01
China Standard Classification Number:
Instruments and meters>>Testing machines and nondestructive testing instruments>>N78X-ray, magnetic powder, fluorescent and other flaw detection instruments
alternative situation:
Replaced by JB/T 6870-2005
Skip to download
Summary:
JB/T 6870-1993 Technical Specifications for Rotating Magnetic Field Flaw Detectors JB/T6870-1993 Standard Download Decompression Password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Technical Conditions for Rotating Magnetic Field Flaw Detectors
Subject Content and Scope of Application
JB/T6870—93
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging, transportation and storage requirements for rotating magnetic field flaw detectors (hereinafter referred to as flaw detectors).
This standard applies to rotating magnetic field magnetic particle flaw detectors generated by cross yokes. 2 Reference standards
GB191 Packaging, storage and transportation pictorial marks
GB/T2611 General technical requirements for testing machines
GB6388 Shipping and receiving marks for transport packaging
JB/T6147 Technical requirements for testing machine packaging, packaging marks, storage and transportation ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters 3 Terms
3.1 Crossed yoke:bzxz.net
A magnetizing device composed of two yoke-shaped electromagnets that cross in space or cross in plane at a certain angle and are excited by two sets of alternating currents with different phases.
3.2 Effective magnetization range: The maximum magnetization area that meets the requirements of detection sensitivity. 3.3 Suction: Also known as lifting force.
The attraction between the magnetic extreme end face of the cross yoke and the flaw detection surface. Technical requirements
The flaw detector should work normally under the following environmental conditions: 4.1
Environmental temperature: 0~40℃;
Relative air humidity is not more than 80%;
The power supply voltage fluctuation shall not exceed ±10% of the rated power supply voltage; There shall be no large amount of dust, flammable or corrosive gas in the surrounding environment. The rated working voltage error of the flaw detector shall not exceed the provisions of Table 1. The phase difference between the two sets of working voltages shall be: 90°±5° or 120°±5°Table 1
Rated working voltage (V)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Technical Conditions for Rotating Magnetic Field Flaw Detectors
Subject Content and Scope of Application
JB/T6870—93
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging, transportation and storage requirements for rotating magnetic field flaw detectors (hereinafter referred to as flaw detectors).
This standard applies to rotating magnetic field magnetic particle flaw detectors generated by cross yokes. 2 Reference standards
GB191 Packaging, storage and transportation pictorial marks
GB/T2611 General technical requirements for testing machines
GB6388 Shipping and receiving marks for transport packaging
JB/T6147 Technical requirements for testing machine packaging, packaging marks, storage and transportation ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters 3 Terms
3.1 Crossed yoke:bzxz.net
A magnetizing device composed of two yoke-shaped electromagnets that cross in space or cross in plane at a certain angle and are excited by two sets of alternating currents with different phases.
3.2 Effective magnetization range: The maximum magnetization area that meets the requirements of detection sensitivity. 3.3 Suction: Also known as lifting force.
The attraction between the magnetic extreme end face of the cross yoke and the flaw detection surface. Technical requirements
The flaw detector should work normally under the following environmental conditions: 4.1
Environmental temperature: 0~40℃;
Relative air humidity is not more than 80%;
The power supply voltage fluctuation shall not exceed ±10% of the rated power supply voltage; There shall be no large amount of dust, flammable or corrosive gas in the surrounding environment. The rated working voltage error of the flaw detector shall not exceed the provisions of Table 1. The phase difference between the two sets of working voltages shall be: 90°±5° or 120°±5°Table 1
Rated working voltage (V)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 7522-1994 Measurement method of ultrasonic velocity of materials
- GB/T 5009.129-2003 Determination of ethoxyquin residues in fruits
- GB/T 21576-2008 Dangerous goods - Test method of gap for extremely insensitive detonate substance (EIDS)
- QB/T 1600-1992 Wax paper
- JB/T 5106-1991 Basic dimensions of core heads for casting molds
- JJG 506-1987 DC Comparator Bridge
- HG/T 2956.4-2001 Determination of total iron content in boron and magnesium ores - Potassium dichromate volumetric method
- JB/T 10335-2002 Classification and code method of linear motion rolling bearings
- SY/T 5002-1996 Connection dimensions of wearing parts of double-acting drilling pumps
- NY/T 703-2003 Safflower
- GB 9838-1988 N Soil and plant standard samples
- MT 244.1-2005 Coal mine narrow gauge vehicle connectors and chains
- JB/T 10401.1-2004 Braking system of off-grid wind turbine generator set Part 1: Technical requirements
- GB 19152-2003 Light motorcycle headlamp photometric performance
- JB/T 6459-1992 Technical Specifications for Battery Counterbalance Trucks
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com