GB 4909.9-1985 Test methods for bare wires - Coating continuity test - Sodium polysulfide method

time: 2024-08-05 03:16:00
  • GB 4909.9-1985
  • in force

Basic Information

standard classification number

  • Standard ICS number:

    Electrical engineering>>Wires and cables>>29.060.10 Wires
  • China Standard Classification Number:

    Electrical Engineering>>Electrical Materials and General Parts>>K11 Bare Wire

associated standards

Publication information

  • publishing house:

    China Standards Press
  • Publication date:

    1985-01-02

Other Information

  • Release date:

    1985-01-31
  • Review date:

    2004-10-14
  • Drafter:

    Fan Man'e
  • Drafting Organization:

    Shanghai Cable Institute
  • Focal point Organization:

    National Wire and Cable Standardization Technical Committee
  • Proposing Organization:

    Ministry of Machinery Industry of the People's Republic of China
  • Publishing Department:

    China Electrical Equipment Industry Association
  • Competent Authority:

    China Electrical Equipment Industry Association
Introduction to standardsDescription (Translated English) / download

Skip to download

Summary:

This test method is suitable for checking the continuity of metal plating (such as tin, silver, nickel, etc.) on wire and cable conductors. GB 4909.9-1985 Bare wire test method Plating continuity test Sodium polysulfide method GB4909.9-1985 Standard download decompression password: www.bzxz.net
Standard contentStandard content

Some standard content:

National Standard of the People's Republic of ChinabZxz.net
Test methods for bare wires
Test for continuity of coatingSodium polysulfide solution methodUDC 621.315.14
GB 4909.9--85
The provisions of this standard are consistent with the relevant provisions of ASTMB33 (1981), ASTMB298 (1980) and ASTMB355 (1980).
1 Scope of application
This test method is applicable to checking the continuity of metal coatings (such as tin, silver, nickel, etc.) of wire and cable conductors. 2 Test equipment
2.1 Glass measuring cylinder 250ml.
2.2 Reagents
2.2.1 Hydrochloric acid chemically pure.
2.2.2 Chemically pure sodium sulfide
2.2.3 Sulfur, benzene or ether.
3 Sample preparation
3.1 Sampling The sample should consist of 8 product packaging unit rings or discs. Cut a sample of about 150mm in length from each packaging unit.
3.2 Pretreatment
3.2.1 Soak the sample in appropriate organic solvents such as benzene, ether or trichloroethylene for at least 3 minutes. After taking it out, dry it with a clean soft cloth.
3.2.2 Place the pretreated sample in a clean container and wait for the test. When taking and placing the sample, do not touch the part of the sample immersed in the test solution with your hands, and take care to prevent damage to the surface of the sample. 4 Test steps
4.1 Preparation of hydrochloric acid solution
4.1.1 Chemically pure (CP) hydrochloric acid is diluted with distilled water. The specific gravity of the test hydrochloric acid solution obtained at 16°C is 1.08. 4.1.2 Each portion of hydrochloric acid solution (180ml) used for tinned copper wire test should be treated as invalid after being immersed in the number of specimens specified in the table for 2 cycles.
Published by the National Bureau of Standards on January 31, 1985
Implemented on December 1, 1985
Nominal diameter of specimen dmm
0.072<0.75
0.75441.00