JB/T 6709-1993 Technical requirements for electronic voltage regulators for alternators used in tractors and internal combustion engines
time:
2024-07-11 20:04:06
- JB/T 6709-1993
- Abolished
Standard ID:
JB/T 6709-1993
Standard Name:
Technical requirements for electronic voltage regulators for alternators used in tractors and internal combustion engines
Chinese Name:
拖拉机、内燃机用交流发电机电子式电压调节器 技术条件
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-07-29 -
Date of Implementation:
1994-01-01 -
Date of Expiration:
2007-03-01
China Standard Classification Number:
Vehicles>>Tractors>>T68 Electrical Appliances and Instruments
alternative situation:
Replaced by JB/T 6709-2006
Focal point Organization:
Luoyang Tractor Research InstitutePublishing Department:
Luoyang Tractor Research Institute
Skip to download
Summary:
This standard specifies the technical requirements, inspection rules, marking, packaging and storage of electronic voltage regulators for alternators used in agricultural tractors and internal combustion engines. This standard applies to regulators for alternators on agricultural tractors, agricultural transport vehicles and stationary internal combustion engines. Regulators for alternators for other purposes can be used as a reference. The regulator works in conjunction with the alternator and battery to keep the generator output voltage within the specified range. JB/T 6709-1993 Technical requirements for electronic voltage regulators for alternators used in tractors and internal combustion engines JB/T6709-1993 Standard download decompression password: www.bzxz.net
Some standard content:
Machinery Industry Standard of the People's Republic of China
JB/T6709-93
AC generators for tractors and internal combustion engines
Technical conditions for electronic voltage regulators
Published on July 29, 1993
Ministry of Machinery Industry of the People's Republic of China
Implementation on January 1, 1994
The hot performance of the regulator shall comply with the requirements of Table 2. Test items
JB/T6709~93
Operating condition of generator during test
[=10%x(≥5A)
8;=2000r/min
nz=8500r/min
I=10%I(≥5A)
[,=10%I
Rated voltage
Adjust voltage value or adjust voltage difference AU
14.2±0.25
IAU≤0.5
Note: The and in the table are rated current and rated speed of AC generator. The regulator should be able to withstand 100 times of full load dump test of AC generator. After the test, the performance of the regulator should comply with the provisions of Article 3.10. 3.11
The saturation voltage drop of the output pole of the regulator should comply with the provisions of Table 3. Table 3
Ig(av)
Note, DC working current is the maximum average value of the AC generator field current. The freewheeling diode voltage drop of the regulator shall comply with the provisions of Table 4. 3.13
DC working current Is(AV)
Freewheeling diode current
Freewheeling diode voltage drop
The regulator shall be subjected to fixed frequency vibration test in three directions of up and down, left and right, and front and back, and swept frequency vibration test or impact test in up and down direction. JB/T6709-93
The load current is reduced to 10%Ix (not less than 5A), and the thermal performance of the regulator is tested. a
Internal grounding
External regulator
Internal grounding
Internal regulator
Figure 1 Test circuit diagram
External grounding
d External grounding
4.7 Load dump test Run for 10s at the rated speed and rated current of the equipped AC generator, then immediately dump the load (including the battery) and switch to no-load operation for 15s. This is one load dump, and it is carried out 100 times in total. 4.8 The output pole saturation voltage drop test circuit is shown in Figure 2. The input variable voltage U is equal to 13V (referring to 14 volts) or 26V (referring to 28 volts). The resistor R is adjusted so that the ammeter indication value reaches the specified value of I in Table 3 of Article 3.12. The time is not more than 30
外措铁
, and then the output pole saturation voltage drop U.. is measured. Test Dwww.bzxz.net
内措铁
Figure 2 Schematic diagram of output pole saturation voltage drop test
4.9 The freewheeling diode voltage drop test circuit is shown in Figure 3. The resistor R is adjusted so that the external DC current reaches the specified value of Table 4 of Article 3.13, and then the voltage drop U of the regulator freewheeling diode is measured. The test time is not more than 30s. External ground
Figure 3 Schematic diagram of freewheeling diode voltage drop test
Internal ground
JB/T6709-93
6.4 The text and logo on the outer wall of each packaging box should include the following:6.4.1 Shipping text and logo: name and address of the consignee, product name, product model, quantity, shipping unit and address. 2 Text and logo of transportation operation; total weight of each box, "handle with care", "anti-vibration", "moisture-proof", "anti-corrosion"6. 4. 2
6.5 Technical documents accompanying the product when it leaves the factory:
Packing list;
Product factory certificate;
Instruction manual.
During storage, the product must not be exposed to moisture, corrosion, heavy pressure, collision, and must not come into contact with corrosive substances such as acids and alkalis and organic solvents. 6.6
Additional instructions:
This standard is proposed by the National Technical Committee for Tractor Standardization. This standard is under the jurisdiction of the Luoyang Tractor Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Automotive Electrical Appliance Factory. The main drafters of this standard are Mi Huiping and Shen Xingzu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T6709-93
AC generators for tractors and internal combustion engines
Technical conditions for electronic voltage regulators
Published on July 29, 1993
Ministry of Machinery Industry of the People's Republic of China
Implementation on January 1, 1994
The hot performance of the regulator shall comply with the requirements of Table 2. Test items
JB/T6709~93
Operating condition of generator during test
[=10%x(≥5A)
8;=2000r/min
nz=8500r/min
I=10%I(≥5A)
[,=10%I
Rated voltage
Adjust voltage value or adjust voltage difference AU
14.2±0.25
IAU≤0.5
Note: The and in the table are rated current and rated speed of AC generator. The regulator should be able to withstand 100 times of full load dump test of AC generator. After the test, the performance of the regulator should comply with the provisions of Article 3.10. 3.11
The saturation voltage drop of the output pole of the regulator should comply with the provisions of Table 3. Table 3
Ig(av)
Note, DC working current is the maximum average value of the AC generator field current. The freewheeling diode voltage drop of the regulator shall comply with the provisions of Table 4. 3.13
DC working current Is(AV)
Freewheeling diode current
Freewheeling diode voltage drop
The regulator shall be subjected to fixed frequency vibration test in three directions of up and down, left and right, and front and back, and swept frequency vibration test or impact test in up and down direction. JB/T6709-93
The load current is reduced to 10%Ix (not less than 5A), and the thermal performance of the regulator is tested. a
Internal grounding
External regulator
Internal grounding
Internal regulator
Figure 1 Test circuit diagram
External grounding
d External grounding
4.7 Load dump test Run for 10s at the rated speed and rated current of the equipped AC generator, then immediately dump the load (including the battery) and switch to no-load operation for 15s. This is one load dump, and it is carried out 100 times in total. 4.8 The output pole saturation voltage drop test circuit is shown in Figure 2. The input variable voltage U is equal to 13V (referring to 14 volts) or 26V (referring to 28 volts). The resistor R is adjusted so that the ammeter indication value reaches the specified value of I in Table 3 of Article 3.12. The time is not more than 30
外措铁
, and then the output pole saturation voltage drop U.. is measured. Test Dwww.bzxz.net
内措铁
Figure 2 Schematic diagram of output pole saturation voltage drop test
4.9 The freewheeling diode voltage drop test circuit is shown in Figure 3. The resistor R is adjusted so that the external DC current reaches the specified value of Table 4 of Article 3.13, and then the voltage drop U of the regulator freewheeling diode is measured. The test time is not more than 30s. External ground
Figure 3 Schematic diagram of freewheeling diode voltage drop test
Internal ground
JB/T6709-93
6.4 The text and logo on the outer wall of each packaging box should include the following:6.4.1 Shipping text and logo: name and address of the consignee, product name, product model, quantity, shipping unit and address. 2 Text and logo of transportation operation; total weight of each box, "handle with care", "anti-vibration", "moisture-proof", "anti-corrosion"6. 4. 2
6.5 Technical documents accompanying the product when it leaves the factory:
Packing list;
Product factory certificate;
Instruction manual.
During storage, the product must not be exposed to moisture, corrosion, heavy pressure, collision, and must not come into contact with corrosive substances such as acids and alkalis and organic solvents. 6.6
Additional instructions:
This standard is proposed by the National Technical Committee for Tractor Standardization. This standard is under the jurisdiction of the Luoyang Tractor Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Automotive Electrical Appliance Factory. The main drafters of this standard are Mi Huiping and Shen Xingzu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 17466-1998 General requirements for enclosures of electrical accessories for household and similar fixed electrical installations
- JB 8432.2-1996 On-site mixing and loading of granular heavy ammonium oil explosives
- HG/T 3065-1999 Determination of heating loss of precipitated hydrated silicon dioxide in rubber compounding ingredients
- JB/T 7664-1995 Compressed air purification terminology
- GB/T 39319-2020 Coding rules of identification for electronic commerce entity
- JB/T 7772-1995 Oily synthetic fiber lacquer silk
- JB/T 9005.1-1999 Rope groove section of cast pulley for crane
- JB/T 10305-2001 Technical requirements for organic material post insulators for 3.6kV~40.5kV high voltage equipment users
- GB/T 14744-1993 港口轮胎起重机试验方法
- HG 20621-1997 Welding ring loose sleeve steel pipe flange (American system)
- JB/T 7688.6-1995 Technical conditions for metallurgical cranes - integral cranes
- SY/T 5536-2002 Specification for commissioning of crude oil pipelines
- GB 7415-1987 Seed storage of main agricultural crops
- SY 5858-1993 Industrial fire safety regulations for petroleum enterprises
- JB/T 7445.2-1998 Method for compiling models of special processing machine tools
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com