GB 16200-1996 Hygienic standard for cypermethrin in workshop air
time:
2024-08-06 06:47:03
- GB 16200-1996
- in force
Standard ID:
GB 16200-1996
Standard Name:
Hygienic standard for cypermethrin in workshop air
Chinese Name:
车间空气中氰戊菊酯卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1996-04-03 -
Date of Implementation:
1996-09-01
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
Partially replaced by GBZ/T 160.78-2004
publishing house:
China Standards PressISBN:
155066.1-12973Publication date:
2004-04-10
Release date:
1996-04-03Review date:
2004-10-14Drafting Organization:
Nanjing Medical College of Preventive MedicineFocal point Organization:
Ministry of HealthPublishing Department:
State Administration of Technical Supervision Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health
Skip to download
Summary:
This standard specifies the maximum permissible concentration of cypermethrin in the air of a workplace and the monitoring and testing methods. This standard applies to enterprises that produce and use cypermethrin. GB 16200-1996 Hygienic standard for cypermethrin in the air of a workplace GB16200-1996 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Health standard for fenvalerate in the air of workplace
Subject content and scope of application
This standard specifies the maximum permissible concentration of fenvalerate in the air of workplace and the monitoring and inspection methods. This standard applies to enterprises that produce and use fenvalerate. Hygiene requirements
The maximum daily average permissible concentration of fenvalerate in the air of workplace is 0.05mg/m (skin). 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health administrative departments at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 428
GB16200—1996
Implemented on September 1, 1996
A1 Principle
GB 16200--- 1996
Appendix A
Gas chromatography
(Supplement)
Valerythrin in the air is collected with n-hexane, separated by SE-30 column, and detected by electron capture detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis.
The detection limit of this method is 1×105μg (1ul liquid sample is injected). A2 Apparatus
A2.1 Multi-hole glass plate absorption tube.
A2.2 Atmospheric sampler, flow rate 0~1L/min. A2.3 Micro syringe, 1μL.
A2.4 Gas chromatograph, 3Ni electron capture detector. A3 Reagents
A3.1 n-hexane, analytical grade
A3.2 Pure cypermethrin, 96.5% or more. A3.3 Anhydrous sodium sulfate, analytical grade, dried at 120℃ for 1h before use. A3.4 SE-30, chromatographic stationary phase,
A3.5 Chromosorb WHP support, 60-80 mesh. A4 Sampling
Connect two porous glass plate absorption tubes each containing 10mL n-hexane in series, and extract 10L of air at a rate of 0.5L/min. Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: glass column with a length of 1.5m and an inner diameter of 4mm. a.
b. Stationary phase: SE-3o: Chromosorb WHP support = 3:10. c. Temperature: column temperature 260℃;
vaporization chamber temperature 270℃;
detection chamber temperature 280℃.
d, carrier gas (high purity nitrogen): 60mL/min. A5.2 Drawing of standard curve
Weigh 10.0mg of pure fenvalerate, place it in a 10mL volumetric flask, dissolve it with n-hexane and dilute to the scale. Dilute it with n-hexane to 0.01, 0.02, 0.040.08μg/mL fenvalerate standard solution before use. Take 1μL of sample respectively, measure the retention time and peak height. Repeat three times for each concentration, take the average value of the peak height, plot the fenvalerate content against the peak height, and draw the standard curve. Retention time is a qualitative indicator.
A5.3Sample analysis
GB 162001996
Raphin
Figure A1 Chromatogram of fenvalerate
Time, min
Wash the inner wall of the air inlet pipe three times with the absorption liquid in the absorption tube, combine the absorption liquids of the two tubes, wash the absorption tubes 2-3 times with a small amount of n-hexane respectively, and add the washing liquid to the absorption liquid to a total volume of 20mL, mix well, add 0.5g of anhydrous sodium sulfate for dehydration, take 1μL for injection, and use the retention time for qualitative analysis and the peak height for quantitative analysis.
A6Calculation
Where: X-the concentration of fenvalerate in the air, mg/m, CbzxZ.net
CThe concentration of fenvalerate found on the standard deduction curve, μg/mL; V. The sampling volume under standard conditions, L. Additional notes:
This standard is proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by Nanjing Medical University. The main drafters of this standard are Zhai Weilei and Chen Yongjin. Al)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health. 130
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Health standard for fenvalerate in the air of workplace
Subject content and scope of application
This standard specifies the maximum permissible concentration of fenvalerate in the air of workplace and the monitoring and inspection methods. This standard applies to enterprises that produce and use fenvalerate. Hygiene requirements
The maximum daily average permissible concentration of fenvalerate in the air of workplace is 0.05mg/m (skin). 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health administrative departments at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 428
GB16200—1996
Implemented on September 1, 1996
A1 Principle
GB 16200--- 1996
Appendix A
Gas chromatography
(Supplement)
Valerythrin in the air is collected with n-hexane, separated by SE-30 column, and detected by electron capture detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis.
The detection limit of this method is 1×105μg (1ul liquid sample is injected). A2 Apparatus
A2.1 Multi-hole glass plate absorption tube.
A2.2 Atmospheric sampler, flow rate 0~1L/min. A2.3 Micro syringe, 1μL.
A2.4 Gas chromatograph, 3Ni electron capture detector. A3 Reagents
A3.1 n-hexane, analytical grade
A3.2 Pure cypermethrin, 96.5% or more. A3.3 Anhydrous sodium sulfate, analytical grade, dried at 120℃ for 1h before use. A3.4 SE-30, chromatographic stationary phase,
A3.5 Chromosorb WHP support, 60-80 mesh. A4 Sampling
Connect two porous glass plate absorption tubes each containing 10mL n-hexane in series, and extract 10L of air at a rate of 0.5L/min. Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: glass column with a length of 1.5m and an inner diameter of 4mm. a.
b. Stationary phase: SE-3o: Chromosorb WHP support = 3:10. c. Temperature: column temperature 260℃;
vaporization chamber temperature 270℃;
detection chamber temperature 280℃.
d, carrier gas (high purity nitrogen): 60mL/min. A5.2 Drawing of standard curve
Weigh 10.0mg of pure fenvalerate, place it in a 10mL volumetric flask, dissolve it with n-hexane and dilute to the scale. Dilute it with n-hexane to 0.01, 0.02, 0.040.08μg/mL fenvalerate standard solution before use. Take 1μL of sample respectively, measure the retention time and peak height. Repeat three times for each concentration, take the average value of the peak height, plot the fenvalerate content against the peak height, and draw the standard curve. Retention time is a qualitative indicator.
A5.3Sample analysis
GB 162001996
Raphin
Figure A1 Chromatogram of fenvalerate
Time, min
Wash the inner wall of the air inlet pipe three times with the absorption liquid in the absorption tube, combine the absorption liquids of the two tubes, wash the absorption tubes 2-3 times with a small amount of n-hexane respectively, and add the washing liquid to the absorption liquid to a total volume of 20mL, mix well, add 0.5g of anhydrous sodium sulfate for dehydration, take 1μL for injection, and use the retention time for qualitative analysis and the peak height for quantitative analysis.
A6Calculation
Where: X-the concentration of fenvalerate in the air, mg/m, CbzxZ.net
CThe concentration of fenvalerate found on the standard deduction curve, μg/mL; V. The sampling volume under standard conditions, L. Additional notes:
This standard is proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by Nanjing Medical University. The main drafters of this standard are Zhai Weilei and Chen Yongjin. Al)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health. 130
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2212.17-1996 Construction tools (brick and mortar) Single-edged masonry knives
- JB/T 56015-2002 Reliability index and test method of electromagnetic intermediate relay
- DL/T 958-2005 Terminology of fuel for power plant
- GB 8943.1-1988 Determination of copper content in pulp, paper and paperboard
- QB 1386-1991 Canned Apricot Jam
- GB/T 14765-1993 Cross handle socket wrench
- SJ 2534.7-1986 Test procedures for antennas-On-site measurements of amplitude pattens
- HG/T 3599-1999 Sulfur yellow brown 4GR (Sulfur yellow brown 6G150%)
- GB/T 17248.4-1998 Acoustics--Noise emitted by machinery and equipment--Determination of emission sound pressure level at a workstation and at other specified position from the sound power level
- MT 222-1996 Local ventilation fans for coal mines
- JB/T 6631-1993 Spiral tube heat exchanger for mechanical seal system
- JB/T 7111-1993 High voltage shunt capacitor device
- GB/T 38475-2020 Detection of mycotoxins in pigment—Rapid quantitative method of colloidal gold strip test
- GB 18279-2000 医疗器械 环氧乙烷灭菌确认和常规控制
- JB/T 8020.1-1999 Thin stoppers for machine tool fixture parts and components
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com