JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C
time:
2024-06-29 15:34:49
- JB/T 6213.2-1992
- Abolished
Standard ID:
JB/T 6213.2-1992
Standard Name:
Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C
Chinese Name:
电机绕组引接软电缆和软线 第2 部分 连续运行导体最高温度为70℃的软电缆和软线
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-06-16 -
Date of Implementation:
1993-01-01 -
Date of Expiration:
2007-07-01
China Standard Classification Number:
Electrical Engineering>>Electrical Materials and General Parts>>K13 Cables and Accessories
alternative situation:
Replaced by JB/T 6213.2-2006Procurement status:
BS 6195 NEQ AS-40007 NEQ
Focal point Organization:
Shanghai Cable Research InstitutePublishing Department:
Shanghai Cable Research Institute
Skip to download
Summary:
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 70°C. This standard applies to flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 70°C. In addition to meeting the requirements specified in this standard, this standard shall also meet the relevant provisions of JB 6213.1. JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C JB/T6213.2-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Flexible cables and cords for connecting motor windings
Part 2 Flexible cables and cords with a continuous operating conductor temperature of 70°C
Subject content and scope of application
JB6213.2-92
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C.
This standard applies to flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C. In addition to meeting the requirements specified in this standard, the products shall also meet the relevant provisions of JB6213.1. Reference standards
Flexible cables and cords for connecting motor windings Part 1 3 Usage characteristics
General provisions
3.1 The AC rated voltage of the cable (wire) is 500, 1000, 3000, 6000V. 3.2 The maximum temperature of the continuous running conductor of the cable (wire) is 70°C. 3.3
The allowable bending radius of the cable (wire) during laying should not be less than 4 times the outer diameter of the cable (wire). Model
The model of the cable (wire) product is as specified in Table 1. Table
5 Specifications
Specifications are as specified in Table 2
Copper core polyvinyl chloride insulated motor winding lead-in cable (wire) Copper core nitrile polyvinyl chloride composite insulated motor winding lead-in cable (wire) Copper core rubber insulated nitrile sheathed motor winding lead-in cable (wire) Copper core rubber insulated chloroprene sheathed motor winding lead-in cable (wire) Ministry of Machinery and Electronics Industry 1992~-06-16 Approved 10
1993-01-—01 Implementation
JV, JF
JB 6213.2--92
Rated voltage
The structure of the cable (wire) is as specified in Table 3. Table
Nominal cross section
JV, JF
Nominal insulation thickness Average outer diameter upper limit
Test and inspection rules
Nominal insulation thickness
3000V6000VwwW.bzxz.Net
Cables (wires) are tested according to the items specified in Table 4. 2.3
JXN, JXF
Nominal sheath thickness
Nominal cross section
Average outer diameter upper limit
1000v3000vj6909v
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Flexible cables and cords for connecting motor windings
Part 2 Flexible cables and cords with a continuous operating conductor temperature of 70°C
Subject content and scope of application
JB6213.2-92
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C.
This standard applies to flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C. In addition to meeting the requirements specified in this standard, the products shall also meet the relevant provisions of JB6213.1. Reference standards
Flexible cables and cords for connecting motor windings Part 1 3 Usage characteristics
General provisions
3.1 The AC rated voltage of the cable (wire) is 500, 1000, 3000, 6000V. 3.2 The maximum temperature of the continuous running conductor of the cable (wire) is 70°C. 3.3
The allowable bending radius of the cable (wire) during laying should not be less than 4 times the outer diameter of the cable (wire). Model
The model of the cable (wire) product is as specified in Table 1. Table
5 Specifications
Specifications are as specified in Table 2
Copper core polyvinyl chloride insulated motor winding lead-in cable (wire) Copper core nitrile polyvinyl chloride composite insulated motor winding lead-in cable (wire) Copper core rubber insulated nitrile sheathed motor winding lead-in cable (wire) Copper core rubber insulated chloroprene sheathed motor winding lead-in cable (wire) Ministry of Machinery and Electronics Industry 1992~-06-16 Approved 10
1993-01-—01 Implementation
JV, JF
JB 6213.2--92
Rated voltage
The structure of the cable (wire) is as specified in Table 3. Table
Nominal cross section
JV, JF
Nominal insulation thickness Average outer diameter upper limit
Test and inspection rules
Nominal insulation thickness
3000V6000VwwW.bzxz.Net
Cables (wires) are tested according to the items specified in Table 4. 2.3
JXN, JXF
Nominal sheath thickness
Nominal cross section
Average outer diameter upper limit
1000v3000vj6909v
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 14237-1993 Manufacturers declaration of export product conformity with STANDARDs
- GB/T 39420-2020 Marine observation terminology
- GB 4776-1984 Electrical safety terminology
- GB/T 15566.10-2009 Guidance system for public information—Setting principles and requirements—Part 10:Street blocks
- GB 3405-1989 Petroleum benzene
- GB 6246-2001 Performance requirements and test methods for lined fire hoses
- CB/T 3954-2002 Marine hot oil boiler
- GB/T 4465-2003 Determination of color intensity and strength of basic dyes
- GB 50290-1998 Technical specification for application of geosynthetics
- JB/T 5810-1991 Specification for interturn insulation test of motor pole coils and field windings
- HG/T 21557.1-1995 Carbon steel step ring packing
- GB 13042-1991 Packing containers-Aerosol cans
- GB/T 15946-1995 Standard digital interface for programmable measuring equipment
- GB 17404-1998 Good Manufacturing Practice for Puffed Foods
- QB/T 2323-2004 Industrial washing machines
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com