
GB 16215-1996 Hygienic standard for phthalic anhydride in workplace air
time:
2024-08-06 06:37:29
- GB 16215-1996
- Abolished
Standard ID:
GB 16215-1996
Standard Name:
Hygienic standard for phthalic anhydride in workplace air
Chinese Name:
车间空气中邻苯二甲酸酐卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1996-04-03 -
Date of Implementation:
1996-09-01 -
Date of Expiration:
2004-12-01
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
Replaced by GBZ/T 160.60-2004
Release date:
1996-04-03Review date:
2004-10-14Drafting Organization:
Shanghai Labor Hygiene and Occupational Disease Prevention and Control InstituteFocal point Organization:
Ministry of HealthPublishing Department:
State Administration of Technical Supervision Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the maximum permissible concentration of phthalic anhydride in the air of a workshop and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use phthalic anhydride. GB 16215-1996 Hygienic standard for phthalic anhydride in the air of a workshop GB16215-1996 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Health standard for phthalic anhydride in the air of workplace Subject content and scope of application
GB16215—1996
This standard specifies the maximum allowable concentration of phthalic anhydride in the air of workplace and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use phthalic anhydride. 2 Hygiene requirements
The maximum allowable concentration of phthalic anhydride in the air of workplace is 1mg/m. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A (supplement). Approved by the State Administration of Technical Supervision on April 3, 1996, and implemented on September 1, 1996
A1 Principle
GB16215-1996
Appendix A
Gas chromatography
(Supplement)
Air 4 Phthalic anhydride is separated by polyethylene succinate and detected by hydrogen flame ionization detector. Retention time is qualitative and peak height is quantitative.
A2 Instruments
A2.1 Whatman, quantitative filter paper (ASHLESS42); or domestic slow quantitative filter paper. A2.2 Sampling clip and air sampler.
A2.3 Stoppered test tube, 5 or 10 ml.
A2.4 Micro-based syringe.
A2.5 Gas chromatograph, hydrogen ionization detector. Chromatographic conditions
Chromatographic column, column length 2m, inner diameter 3mm, stainless steel column. Polyethylene glycol ester: 101 silanized white support: phosphoric acid 5:100:1.5b.
Column temperature, 175C.
Vaporization chamber temperature, 220℃. Www.bzxZ.net
Detection chamber temperature, 220℃.
Nitrogen, 25mL/min.
A3 Reagents
A3.1 Polyethylene succinate, chromatographic stationary liquid. A3.2101 silanized white support, 60-80 mesh. A3.3 Phthalic anhydride, purity 99%, chemically pure. A3.4 Acetone, analytically pure.
A3.5 Phosphoric acid, analytically pure.
A4 Sampling
Take two circular filter papers with a diameter of 17mm to 25mm and put them in the sampling clip. Take 20 to 30L of air at the sampling site at a speed of 1L/min. A5 Analysis steps
A5.1 Control test: Same as the sampling operation, but no air sample is collected. A5.2 Sample processing: Take out the filter paper, fold it and put it into a stoppered test tube, add 1mL acetone, soak the filter paper in acetone, and number it for analysis.
A5.3 Standard curve drawing: Prepare 10.2.20.4, 50.9, 101.8, 203.6μg/mL phthalic anhydride acetone solutions respectively. According to the above chromatographic conditions, inject 1uL respectively. Measure each concentration 6 times, take the peak height as the average, plot the phthalic anhydride concentration against the peak height, and draw the standard curve.
A5.4 Determination: Take 1ul of sample solution and inject it. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. 47.4
A6 Calculation
GB16215-1996
Where: X—phthalic anhydride concentration in the air, mg/m\; Ci+c
(, C2 is the standard phthalic anhydride content measured by the front and rear filter papers, μg; V-the sampling volume converted to standard conditions, L. A7 Description
A7.1 The detection limit of this method is 8.93×10-5μg/5mm peak height (injection volume 1μL). A7.2 The sampling efficiency of Whatman filter paper is 95% (the sampling efficiency of glass fiber filter membrane or domestic quantitative filter paper is about 80%). A7.3 The elution efficiency of this method is above 95%.
A7.4 After sampling, the filter paper should be completely immersed in 1mL acetone after folding, and then added The plug is sealed and can be stored for 7 days. When analyzing, the solution must not be dried. Otherwise, 1 mL of acetone should be added before sampling. A7.5 Maleic anhydride and 1,4-naphthaldehyde that may coexist in the air on site will not interfere with the determination. A7.6 Prevent contamination when installing and removing filter paper for on-site sampling. A7.7 There should be no blanks in acetone and filter paper, that is, the filter paper is soaked in 1 mL of acetone solution, and 1 μL is taken for chromatographic analysis. There should be no response. If there is a blank, it needs to be processed before sampling and analysis. Additional notes:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Shanghai Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard are Fu Weizu, Luo Shengqing, and Zhang Ge. This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, which is the technical management unit entrusted by the Ministry of Health. 475
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Health standard for phthalic anhydride in the air of workplace Subject content and scope of application
GB16215—1996
This standard specifies the maximum allowable concentration of phthalic anhydride in the air of workplace and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use phthalic anhydride. 2 Hygiene requirements
The maximum allowable concentration of phthalic anhydride in the air of workplace is 1mg/m. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A (supplement). Approved by the State Administration of Technical Supervision on April 3, 1996, and implemented on September 1, 1996
A1 Principle
GB16215-1996
Appendix A
Gas chromatography
(Supplement)
Air 4 Phthalic anhydride is separated by polyethylene succinate and detected by hydrogen flame ionization detector. Retention time is qualitative and peak height is quantitative.
A2 Instruments
A2.1 Whatman, quantitative filter paper (ASHLESS42); or domestic slow quantitative filter paper. A2.2 Sampling clip and air sampler.
A2.3 Stoppered test tube, 5 or 10 ml.
A2.4 Micro-based syringe.
A2.5 Gas chromatograph, hydrogen ionization detector. Chromatographic conditions
Chromatographic column, column length 2m, inner diameter 3mm, stainless steel column. Polyethylene glycol ester: 101 silanized white support: phosphoric acid 5:100:1.5b.
Column temperature, 175C.
Vaporization chamber temperature, 220℃. Www.bzxZ.net
Detection chamber temperature, 220℃.
Nitrogen, 25mL/min.
A3 Reagents
A3.1 Polyethylene succinate, chromatographic stationary liquid. A3.2101 silanized white support, 60-80 mesh. A3.3 Phthalic anhydride, purity 99%, chemically pure. A3.4 Acetone, analytically pure.
A3.5 Phosphoric acid, analytically pure.
A4 Sampling
Take two circular filter papers with a diameter of 17mm to 25mm and put them in the sampling clip. Take 20 to 30L of air at the sampling site at a speed of 1L/min. A5 Analysis steps
A5.1 Control test: Same as the sampling operation, but no air sample is collected. A5.2 Sample processing: Take out the filter paper, fold it and put it into a stoppered test tube, add 1mL acetone, soak the filter paper in acetone, and number it for analysis.
A5.3 Standard curve drawing: Prepare 10.2.20.4, 50.9, 101.8, 203.6μg/mL phthalic anhydride acetone solutions respectively. According to the above chromatographic conditions, inject 1uL respectively. Measure each concentration 6 times, take the peak height as the average, plot the phthalic anhydride concentration against the peak height, and draw the standard curve.
A5.4 Determination: Take 1ul of sample solution and inject it. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. 47.4
A6 Calculation
GB16215-1996
Where: X—phthalic anhydride concentration in the air, mg/m\; Ci+c
(, C2 is the standard phthalic anhydride content measured by the front and rear filter papers, μg; V-the sampling volume converted to standard conditions, L. A7 Description
A7.1 The detection limit of this method is 8.93×10-5μg/5mm peak height (injection volume 1μL). A7.2 The sampling efficiency of Whatman filter paper is 95% (the sampling efficiency of glass fiber filter membrane or domestic quantitative filter paper is about 80%). A7.3 The elution efficiency of this method is above 95%.
A7.4 After sampling, the filter paper should be completely immersed in 1mL acetone after folding, and then added The plug is sealed and can be stored for 7 days. When analyzing, the solution must not be dried. Otherwise, 1 mL of acetone should be added before sampling. A7.5 Maleic anhydride and 1,4-naphthaldehyde that may coexist in the air on site will not interfere with the determination. A7.6 Prevent contamination when installing and removing filter paper for on-site sampling. A7.7 There should be no blanks in acetone and filter paper, that is, the filter paper is soaked in 1 mL of acetone solution, and 1 μL is taken for chromatographic analysis. There should be no response. If there is a blank, it needs to be processed before sampling and analysis. Additional notes:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Shanghai Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard are Fu Weizu, Luo Shengqing, and Zhang Ge. This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, which is the technical management unit entrusted by the Ministry of Health. 475
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- CB/T 711-1995 Spike Anchor
- QB/T 3778-1999 Crude lactose
- QB/T 2343.2-1997 Test method for brown sugar
- HG/T 2713-1995 Casting pearlescent organic glass sheet
- GB/T 4249-1996 Tolerance Principles
- GB/T 8762.8-2000 Chemical analysis method for europium oxide - Determination of lanthanum oxide, cerium oxide, praseodymium oxide, neodymium oxide, samarium oxide, gadolinium oxide, terbium oxide, dysprosium oxide, holmium oxide, erbium oxide, thulium oxide, ytterbium oxide, lutetium oxide and tantalum oxide in europium oxide by inductively coupled plasma atomic emission spectrometry
- GB 10457-1989 Polyethylene self-adhesive cling film
- HG 20559-1993 Pipeline Instrument Flowchart Design Regulations
- HG/T 3050.2-2001 Rubber or plastic coated fabrics - Determination of properties of the whole roll - Part 2: Determination of total mass per unit area, coating mass per unit area
- JB/T 9165.3-1998 Management process document format
- GBZ 121-2002 Standard for health protection of afterloaded gamma source brachytherapy
- JB/T 9220.11-1999 Chemical analysis of acidic slag from foundry cupola furnaces - Combustion-potassium iodate volumetric method for determination of sulfur content
- MT/T 660-1997 Specifications and dimensions of vibrating screens for coal
- GB/T 15234-1994 Plastics flat pallets
- GB/T 4339-1999 Determination of characteristic parameters of thermal expansion of metallic materials
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com