GB/T 4464-1984 Determination of dye migration
time:
2024-08-05 09:05:30
- GB/T 4464-1984
- Abolished
Standard ID:
GB/T 4464-1984
Standard Name:
Determination of dye migration
Chinese Name:
染料泳移性测定法
Standard category:
National Standard (GB)
-
Date of Release:
1984-06-05 -
Date of Implementation:
1985-03-01 -
Date of Expiration:
2007-01-01
Standard ICS number:
Paint and pigment industry>>Paint ingredients>>87.060.10 Pigments and fillersChina Standard Classification Number:
Chemicals>>Coatings, Pigments, Dyes>>G55 Basic Standards and General Methods for Dyes
alternative situation:
Replaced by GB/T 4464-2006
Review date:
2004-10-14Drafting Organization:
Shenyang Research Institute of Chemical IndustryFocal point Organization:
National Dye Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
This standard is applicable to the determination of the migration of disperse and vat dyes during the intermediate drying process. The migration of dyes is evaluated by percentage migration rate (measurement of reflection value or transmission value) or by visual inspection. GB/T 4464-1984 Determination of migration of dyes GB/T4464-1984 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Test method of dyestuff migration
Test method of dyestuff migration UDC 661.21
GB 4464-84
This standard applies to the determination of the migration of disperse and vat dyes during the intermediate drying process. The migration of dyes is evaluated by the migration rate (measurement of reflectance or transmission value) or by visual inspection. 1 Materials and instruments
t.1 Fabric material: refined bleached mercerized polyester-cotton khaki (polyester/cotton is 65/35), with a yarn count of 42×21 and a density of 135×70. The size of the test fabric is 110 mm×220 mm. 1.2 Color fastness fading sample card (GB250-84). 1.3 Surface: diameter 90 mm.
1.4 Aluminum ring, outer diameter 110 mm, inner diameter 80 mm, thickness 1 mm. 1.5 Stationery clips.
1.6 Laboratory roller and hot melt machine (or electric blast oven). 2 Reagents and solutions
Dimethylformamide: analytical grade.
36% acetic acid (1IC3-1095-77): analytical grade. 2.2
Sodium hydroxide (GB629-81): analytical grade. Hydroxide (HG2-809-75): chemical grade. 2.4
2.5 Polyvinylpyrrolidone (PVPK-30): chemical grade. 2.6 Disodium tetraethyl diamine (GB1401-78): analytical grade. Preparation of disperse dye extract;
Each liter of solution contains 800 ml of dimethylformamide, 200 ml of water, and 5 ml of 36% acetic acid. 2.8 Preparation of vat dye benzene solution: bZxz.net
Each liter of aqueous solution contains 10 g of sodium hydride, 10 g of hydrosulfite, 20 g of polydiene pyrrolidone, and 5 g of ethylenediaminetetraacetic acid disene. 3 Test method
3.1 Test conditions
Dyeing depth: 20 g/L for disperse dyes and 25 g/L for vat dyes. Rolling rate: 60% (one diffuse and one roll).
Intermediate drying: the lower drying temperature is 100°C and the drying time is 7 minutes. 3.2 Dye sample preparation
First, evenly immerse a piece of test fabric in the roll dye solution for 1 minute, then roll it according to the specified roll rate, and then immediately place the sample on the needle plate frame of the hot melt machine (or oven), fix it and pull it. Place a piece of surface dye on the front and back of the same position at one end of the sample, and then fix the surface dye with a pair of aluminum rings and stationery clips (see the figure below). At the specified temperature and time, pass the sample through a hot melt machine (or place it in an oven) for intermediate drying. After drying, remove the sample from the needle plate frame, remove the clamp, aluminum ring and surface blood, and place it at room temperature for 1 hour for use.
National Bureau of Standards 1984-06-05 Issued
1985-0a ~01 Implementation
3.3 Evaluation method
GB4464-84
[Fabric, 2-Surface 3-Stationery: 4-Aluminum ring 3.3.1 And measure
Refer to the half-color sample card (referred to as gray card), and visually evaluate the color difference between the covered part and the covered part of the sample. When the color difference is equivalent to gray card 1-5 levels or more, the dye migration is small, and the color difference is equivalent to gray card 3-4 levels of migration, etc.: When the color difference is below gray 3 levels, the dye migration is relatively strong. 3.3.2 Measurement of reflection value
Use a colorimeter to measure the surface reflection of the covered part (A) and the covered part (B) of the sample (A and B are about 100 mm apart), and convert it into color depth value (K/S) according to formula (1), and calculate the white migration rate M according to formula (2): KS =
M = 100 [1
Wherein: (K/SA -
(K/S)A
(K/S)g
Color depth of the covered part (A) of the sample; ()
(2)
(K/S)B
GB 4464—84
Color depth value of the uncovered part (B) of the sample: the reflectance value of the sample surface at the wavelength of maximum absorption. 3.3.3 Measurement of transmittance value
Weigh 0.1000 g of fabric from points A and B on the sample respectively, cut into small pieces and place in a 50 ml volumetric flask, then add extract to the scale (select the extract according to the type of dye). When the flask is sealed, the dye on the fabric is taken out, and the absorbance D of the extract is measured at the wavelength of maximum absorption using a photoelectric spectrophotometer. Calculate the percentage migration rate M according to formula (3): = 100 (
Wherein: --- — absorbance of the dye extraction solution at point A on the sample: Da——absorbance of the dye extraction solution at point B on the sample. D
Additional notes:
This standard was proposed by the Ministry of Chemistry of the People's Republic of China and issued by Shenyang Chemical Research Institute. This standard was drafted by the person in charge of Shenyang Chemical Research Institute. The main drafter of this standard is Gao Jiyuan.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test method of dyestuff migration
Test method of dyestuff migration UDC 661.21
GB 4464-84
This standard applies to the determination of the migration of disperse and vat dyes during the intermediate drying process. The migration of dyes is evaluated by the migration rate (measurement of reflectance or transmission value) or by visual inspection. 1 Materials and instruments
t.1 Fabric material: refined bleached mercerized polyester-cotton khaki (polyester/cotton is 65/35), with a yarn count of 42×21 and a density of 135×70. The size of the test fabric is 110 mm×220 mm. 1.2 Color fastness fading sample card (GB250-84). 1.3 Surface: diameter 90 mm.
1.4 Aluminum ring, outer diameter 110 mm, inner diameter 80 mm, thickness 1 mm. 1.5 Stationery clips.
1.6 Laboratory roller and hot melt machine (or electric blast oven). 2 Reagents and solutions
Dimethylformamide: analytical grade.
36% acetic acid (1IC3-1095-77): analytical grade. 2.2
Sodium hydroxide (GB629-81): analytical grade. Hydroxide (HG2-809-75): chemical grade. 2.4
2.5 Polyvinylpyrrolidone (PVPK-30): chemical grade. 2.6 Disodium tetraethyl diamine (GB1401-78): analytical grade. Preparation of disperse dye extract;
Each liter of solution contains 800 ml of dimethylformamide, 200 ml of water, and 5 ml of 36% acetic acid. 2.8 Preparation of vat dye benzene solution: bZxz.net
Each liter of aqueous solution contains 10 g of sodium hydride, 10 g of hydrosulfite, 20 g of polydiene pyrrolidone, and 5 g of ethylenediaminetetraacetic acid disene. 3 Test method
3.1 Test conditions
Dyeing depth: 20 g/L for disperse dyes and 25 g/L for vat dyes. Rolling rate: 60% (one diffuse and one roll).
Intermediate drying: the lower drying temperature is 100°C and the drying time is 7 minutes. 3.2 Dye sample preparation
First, evenly immerse a piece of test fabric in the roll dye solution for 1 minute, then roll it according to the specified roll rate, and then immediately place the sample on the needle plate frame of the hot melt machine (or oven), fix it and pull it. Place a piece of surface dye on the front and back of the same position at one end of the sample, and then fix the surface dye with a pair of aluminum rings and stationery clips (see the figure below). At the specified temperature and time, pass the sample through a hot melt machine (or place it in an oven) for intermediate drying. After drying, remove the sample from the needle plate frame, remove the clamp, aluminum ring and surface blood, and place it at room temperature for 1 hour for use.
National Bureau of Standards 1984-06-05 Issued
1985-0a ~01 Implementation
3.3 Evaluation method
GB4464-84
[Fabric, 2-Surface 3-Stationery: 4-Aluminum ring 3.3.1 And measure
Refer to the half-color sample card (referred to as gray card), and visually evaluate the color difference between the covered part and the covered part of the sample. When the color difference is equivalent to gray card 1-5 levels or more, the dye migration is small, and the color difference is equivalent to gray card 3-4 levels of migration, etc.: When the color difference is below gray 3 levels, the dye migration is relatively strong. 3.3.2 Measurement of reflection value
Use a colorimeter to measure the surface reflection of the covered part (A) and the covered part (B) of the sample (A and B are about 100 mm apart), and convert it into color depth value (K/S) according to formula (1), and calculate the white migration rate M according to formula (2): KS =
M = 100 [1
Wherein: (K/SA -
(K/S)A
(K/S)g
Color depth of the covered part (A) of the sample; ()
(2)
(K/S)B
GB 4464—84
Color depth value of the uncovered part (B) of the sample: the reflectance value of the sample surface at the wavelength of maximum absorption. 3.3.3 Measurement of transmittance value
Weigh 0.1000 g of fabric from points A and B on the sample respectively, cut into small pieces and place in a 50 ml volumetric flask, then add extract to the scale (select the extract according to the type of dye). When the flask is sealed, the dye on the fabric is taken out, and the absorbance D of the extract is measured at the wavelength of maximum absorption using a photoelectric spectrophotometer. Calculate the percentage migration rate M according to formula (3): = 100 (
Wherein: --- — absorbance of the dye extraction solution at point A on the sample: Da——absorbance of the dye extraction solution at point B on the sample. D
Additional notes:
This standard was proposed by the Ministry of Chemistry of the People's Republic of China and issued by Shenyang Chemical Research Institute. This standard was drafted by the person in charge of Shenyang Chemical Research Institute. The main drafter of this standard is Gao Jiyuan.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 7024-1997 Terminology for elevators, escalators and moving walkways
- GB/T 8802-2001 Determination of Vicat softening temperature of thermoplastic pipes and fittings
- GB 15218-1994 Standard for classification and grading of groundwater resources
- GB/T 4678.6-2003 Die casting parts Part 6: Guide bushings with head
- QX/T 344.2-2019 The method of fire monitoring by satellite remote sensing—Part 2:Fire spot discerning
- GB 18243-2000 Plastic modified asphalt waterproofing membrane
- GB 2761-1981 Tolerance of Aflatoxin B1 in Food
- GB/T 15681-1995 Flaxseed
- GB/T 6098-2018 Test method for length of cotton fibres—Roller analyser
- QB/T 2570-2002 Labeling Machine
- GB/T 14867-1994 Fengxiang-style liquor
- JB/T 5332.2-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables
- JB/T 5332.4-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 4 Round power cables for electric submersible pumps
- JB/T 5876.1-1991 电气传动装置制图 系统图和电路图
- GB/T 13823.3-1992 Methods for the calibration of vibration and shock pick-ups Comparison(secondary vibration)calibration by sinusoidal excitation
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com