GB/T 2559-1981 Determination of melting point of lignite wax
time:
2024-08-11 16:42:29
- GB/T 2559-1981
- Abolished
Standard ID:
GB/T 2559-1981
Standard Name:
Determination of melting point of lignite wax
Chinese Name:
褐煤蜡熔点测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1981-04-08 -
Date of Implementation:
1981-10-01 -
Date of Expiration:
2006-04-01
Standard ICS number:
Mining and Mineral Products >> 73.040 CoalChina Standard Classification Number:
Mining>>Solid Fuel Mining>>D22 Coal for Vehicles, Ships and Gas
alternative situation:
Replaced by GB/T 2559-2005
Review date:
2004-10-14Drafting Organization:
Shanxi Coal Chemistry Institute, Chinese Academy of SciencesFocal point Organization:
National Coal Standardization Technical CommitteePublishing Department:
China Coal Industry AssociationCompetent Authority:
China Coal Industry Association
Skip to download
Summary:
GB/T 2559-1981 Determination of melting point of montan wax GB/T2559-1981 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Method for determination of melting point of lignite wax
This method is applicable to the determination of melting point of lignite wax. GB 2559 -
Method Key Points: Place the open capillary tube containing the wax sample into the melting point determination tube water bath and heat it at a certain heating rate. The temperature when the wax column just starts to rise is taken as the melting point of the wax sample. Apparatus
1. Apparatus
(1) Melting point determination tube (see figure)
(2) Porcelain crucible: 50 ml;
(3) Drying box: capable of maintaining 100-110℃; (4) Electric furnace (0-500 watts) or small Bunsen burner; Apparatus
(5) Mercury thermometer: 50-100℃, graduation of 0.1℃ (should be calibrated in advance); (6) Capillary: inner diameter of about 0.8-1.2 mm, length of about 7 0 mm, the tube wall thickness is 0.2-0.3 mm, and both ends are open; (7) Blade.
2. Determination steps
2. Take about 20 grams of representative broken wax sample and put it into a porcelain crucible, then put the crucible into a drying oven at 102-105°C. After the wax melts, stir it occasionally and keep it warm for 1 hour, then let it stand at this temperature for at least 30 minutes. 3. Vertically immerse one end of the cleaned and dried capillary tube into the molten wax sample to a depth of about 10 mm, then take it out, and after it solidifies, use a blade to scrape off the wax adhering to the outside of the capillary tube (there should be no bubbles in the wax column). The wax column at the mouth of the tube should be flattened and placed at room temperature for more than 12 hours or in ice water (0°C). ) and cool for 10 minutes before the measurement. 4. Pour the distilled water that has just been boiled and cooled into the melting point tube, so that the liquid level is about 15 mm above the branch tube mouth, and then fix the melting point tube on the bracket.
5. Tie the upper part of the capillary tube containing the wax sample to the mercury thermometer with a rubber band, so that the wax column in the capillary tube is close to the side of the mercury ball of the thermometer, and tie it to the upper plane of the wax column with a thin rubber band to facilitate the observation of the rise of the wax column. 6. Use a rubber stopper with a hole to fix the thermometer in the melting point tube. The mercury ball of the thermometer should be about 15 mm below the branch tube mouth of the melting point tube (as shown in the figure).
7. Heat the capillary tube with an electric furnace or a small Bunsen burner. For the hot melting point measuring tube, when it is about 10℃ away from the predicted melting point, increase the temperature at a rate of about 1℃ per minute, and observe the temperature when the wax column just starts to rise, which is the melting point of the wax sample. Read to two decimal places. 8. Take the arithmetic mean of the results of two parallel measurements as the measurement result. The result is rounded to one decimal place. III. Permission
9. The difference between parallel measurements shall not exceed the following provisions: Issued by the General Administration of Standards of the People's Republic of China
Proposed by the Ministry of Coal Industry of the People's Republic of China
Implemented on October 1, 1981
Shanxi Coal Chemistry Institute of the Chinese Academy of Sciences
Beijing Coal Chemistry Institute of Coal Research Institute
GB 2559—81
-ThermometerwwW.bzxz.Net
Capillary
Rubber band
Rubber band
Capillary melting point measuring device
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Method for determination of melting point of lignite wax
This method is applicable to the determination of melting point of lignite wax. GB 2559 -
Method Key Points: Place the open capillary tube containing the wax sample into the melting point determination tube water bath and heat it at a certain heating rate. The temperature when the wax column just starts to rise is taken as the melting point of the wax sample. Apparatus
1. Apparatus
(1) Melting point determination tube (see figure)
(2) Porcelain crucible: 50 ml;
(3) Drying box: capable of maintaining 100-110℃; (4) Electric furnace (0-500 watts) or small Bunsen burner; Apparatus
(5) Mercury thermometer: 50-100℃, graduation of 0.1℃ (should be calibrated in advance); (6) Capillary: inner diameter of about 0.8-1.2 mm, length of about 7 0 mm, the tube wall thickness is 0.2-0.3 mm, and both ends are open; (7) Blade.
2. Determination steps
2. Take about 20 grams of representative broken wax sample and put it into a porcelain crucible, then put the crucible into a drying oven at 102-105°C. After the wax melts, stir it occasionally and keep it warm for 1 hour, then let it stand at this temperature for at least 30 minutes. 3. Vertically immerse one end of the cleaned and dried capillary tube into the molten wax sample to a depth of about 10 mm, then take it out, and after it solidifies, use a blade to scrape off the wax adhering to the outside of the capillary tube (there should be no bubbles in the wax column). The wax column at the mouth of the tube should be flattened and placed at room temperature for more than 12 hours or in ice water (0°C). ) and cool for 10 minutes before the measurement. 4. Pour the distilled water that has just been boiled and cooled into the melting point tube, so that the liquid level is about 15 mm above the branch tube mouth, and then fix the melting point tube on the bracket.
5. Tie the upper part of the capillary tube containing the wax sample to the mercury thermometer with a rubber band, so that the wax column in the capillary tube is close to the side of the mercury ball of the thermometer, and tie it to the upper plane of the wax column with a thin rubber band to facilitate the observation of the rise of the wax column. 6. Use a rubber stopper with a hole to fix the thermometer in the melting point tube. The mercury ball of the thermometer should be about 15 mm below the branch tube mouth of the melting point tube (as shown in the figure).
7. Heat the capillary tube with an electric furnace or a small Bunsen burner. For the hot melting point measuring tube, when it is about 10℃ away from the predicted melting point, increase the temperature at a rate of about 1℃ per minute, and observe the temperature when the wax column just starts to rise, which is the melting point of the wax sample. Read to two decimal places. 8. Take the arithmetic mean of the results of two parallel measurements as the measurement result. The result is rounded to one decimal place. III. Permission
9. The difference between parallel measurements shall not exceed the following provisions: Issued by the General Administration of Standards of the People's Republic of China
Proposed by the Ministry of Coal Industry of the People's Republic of China
Implemented on October 1, 1981
Shanxi Coal Chemistry Institute of the Chinese Academy of Sciences
Beijing Coal Chemistry Institute of Coal Research Institute
GB 2559—81
-ThermometerwwW.bzxz.Net
Capillary
Rubber band
Rubber band
Capillary melting point measuring device
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB 20003.5-2004 Eye drops linkage line labeling machine
- SL 312-2005 Technical Management Regulations for Operation of Soil and Water Conservation Projects
- JB/T 5410-1991 Low vacuum electromagnetic pressure differential inflation valve type and
- JB 20025-2004 Fully automatic hard capsule filling machine
- HG/T 2916-1997 Diethanolamine for industrial use
- JB/T 5893.4-1991 Gongxian special grade alumina powder for electrical porcelain raw materials
- HG/T 20704.5-2000 Rules for reviewing design documents for pumps
- JGJ 71-1990 Clean room construction and acceptance specifications
- NY 774-2004 Maximum residue limits for pesticides in leafy vegetable
- GB/T 15972.2-1998 General specification for optical fibres Part 2: Test methods for dimensional parameters
- GB/T 5009.155-2003 Determination of oryzalin residues in rice
- JB/T 9067-1999 Air Curtain
- JB/T 2001.36-1999 Water system filling valve core (PN=20, 31.5MPa)
- SY/T 6520-2001 Test method for crude oil dehydration - Pressure autoclave method
- GB/T 36106-2018 Data management specification of the unified social credit identifier for legal entities and other organizations
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com