GB 4706.31-2003 Safety of household and similar electrical appliances - Particular requirements for sauna and bath heating appliances
time:
2024-08-11 01:49:07
- GB 4706.31-2003
- in force
Standard ID:
GB 4706.31-2003
Standard Name:
Safety of household and similar electrical appliances - Particular requirements for sauna and bath heating appliances
Chinese Name:
家用和类似用途电器的安全 桑那浴加热器具的特殊要求
Standard category:
National Standard (GB)
-
Date of Release:
2003-06-05 -
Date of Implementation:
2004-01-01
Standard ICS number:
Household and commercial equipment, entertainment, sports>>Household, commercial and industrial heating appliances>>97.100.10 Electric heatersChina Standard Classification Number:
Light Industry, Cultural and Living Goods>>Household Appliances, Daily Use Machinery>>Y63 Household Electric Heating Appliances
alternative situation:
Replaces GB 4706.31-1995; replaced by GB 4706.31-2008Procurement status:
IEC 60335-2-53-1997, IDT
publishing house:
China Standards PressISBN:
155066.1-19929Publication date:
2004-01-01
Release date:
1995-07-06Review date:
2004-10-14Drafter:
Huang Wenxiu, Ling Honghao, Li ChengDrafting Organization:
Guangzhou Electric Science Research InstituteFocal point Organization:
National Technical Committee for Standardization of Household Electrical AppliancesProposing Organization:
China Light Industry FederationPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
GB4706 This part deals with the safety of sauna and bath heating appliances with a rated input power not exceeding 20kw, a rated voltage not exceeding 250V for single-phase appliances, and a rated voltage not exceeding 480V for other appliances. This part deals with the common hazards encountered by all persons in and around the house and presented by the appliances. GB 4706.31-2003 Safety of household and similar electrical appliances Particular requirements for sauna and bath heating appliances GB4706.31-2003 Standard download decompression password: www.bzxz.net

Some standard content:
All technical contents of this part of G170G are mandatory. GB 4706.31-2003/IEC60335-2-53:1997 This part adopts IEC 60335-2-53:1997 Safety of household and similar electrical appliances - Particular requirements for heating appliances (English version):
This part is based on GB4706.31-1995 Safety of household and similar electrical appliances - Particular requirements for heating appliances >. This part is a detailed translation of GB 1706-1998:60335-8-53:1997. This part should be used in conjunction with GB 1706-1998:1998 Safety requirements for household and similar appliances - Part 1: General requirements. This part is formed by supplementing or modifying GB 4706.1-1998. If specific clauses in GB 1706.1 are mentioned in this part, it means that the corresponding clauses in GB 4706.1 are applicable to this part. The parts of this part marked with "applicable month" are Indicates that the relevant provisions in GB4706.1 apply to this part; for the parts of this part marked with "replacement", the provisions of this part shall prevail. The parts of this part marked with "addition" indicate that in addition to the relevant provisions of GB1736.1, the additional provisions of this part shall also be included. For the convenience of reading, this part has made the following editorial changes: a) The term "Part 1" was changed to "GB4706.1": h) The decimal point "\" was used instead of the chasing sign "\". In terms of technical content, the main differences between this part and GB4706.31-1995 are as follows: this part should be used in conjunction with GB4706.11998, while GB4706.31-1995 should be used in conjunction with GB4706.1-1992. In Chapter 1 of this part, it is stipulated that the rated voltage of single-phase appliances shall not exceed 400V, and the rated voltage of other appliances shall not exceed 480V. However, GB4706.31-1995 does not have such content. This part defines normal operation in Chapter 2 and stipulates normal operating conditions, while GB4706.31-1995 specifically defines this as "full heat operation" and does not specify the working conditions. Chapter 6, 6.1 of the GK47CE-1 stipulates that "the appliance should meet the requirements of Class II or severe class", and adds "the protection rating of sauna heaters and controllers installed in restricted rooms should be at least IPX4: for ceiling-mounted soft appliances, all electrical components should be at least IPX4", while GK47CE, 31-1 does not contain these contents. Chapter 7.12 of the power supply section adds "the instructions for use of public soft appliances, especially timers, shall specify the method for filling the container"; it also adds "the instructions for use of public soft appliances, especially timers, shall be marketed It should be pointed out that the device must be operated continuously when it is used. The instruction manual of other soft bath heaters should point out that the room should be checked before starting. However, GB47(16.31-1995 does not have this content. Part 7.12.1 of this part adds "Installation instructions for public bath appliances without timers should be indicated. A warning light should be installed in the monitoring to show that the heater is working." GB4755.41-1995 adds this content: Chapter 9 of this part \ Electric belts "Start", this part is not applicable to this state of GB4706.1, GB47CS.3:-106, this chapter of GB4706.1 is applicable". www.bzxz.net
..--This part: 1.7 requires that the device should work until it reaches a certain state, while GB476.311995 stipulates the working hours of heat storage and non-heat storage appliances respectively - this part 11.8 requires that "the environment, walls, floors and ground conditions of the room or prefabricated room should not be forgotten. 15K, while 11. of GB4706.311995 stipulates the surface temperature of "visible or invisible". Part 1.8 of the first car adds "In the room: the temperature of the special handle, shaped handle, gripper and similar parts that are only held for a short time should be increased by 20", while GB47C6.3119S5 does not have this content. 13.2 of GH470.61-199 adds Figure 101, and the leakage protection test that is not carried out according to Figure 101 is also carried out. Except for the "Jun part of the cellar,
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This part is based on GB4706.31-1995 Safety of household and similar electrical appliances - Particular requirements for heating appliances >. This part is a detailed translation of GB 1706-1998:60335-8-53:1997. This part should be used in conjunction with GB 1706-1998:1998 Safety requirements for household and similar appliances - Part 1: General requirements. This part is formed by supplementing or modifying GB 4706.1-1998. If specific clauses in GB 1706.1 are mentioned in this part, it means that the corresponding clauses in GB 4706.1 are applicable to this part. The parts of this part marked with "applicable month" are Indicates that the relevant provisions in GB4706.1 apply to this part; for the parts of this part marked with "replacement", the provisions of this part shall prevail. The parts of this part marked with "addition" indicate that in addition to the relevant provisions of GB1736.1, the additional provisions of this part shall also be included. For the convenience of reading, this part has made the following editorial changes: a) The term "Part 1" was changed to "GB4706.1": h) The decimal point "\" was used instead of the chasing sign "\". In terms of technical content, the main differences between this part and GB4706.31-1995 are as follows: this part should be used in conjunction with GB4706.11998, while GB4706.31-1995 should be used in conjunction with GB4706.1-1992. In Chapter 1 of this part, it is stipulated that the rated voltage of single-phase appliances shall not exceed 400V, and the rated voltage of other appliances shall not exceed 480V. However, GB4706.31-1995 does not have such content. This part defines normal operation in Chapter 2 and stipulates normal operating conditions, while GB4706.31-1995 specifically defines this as "full heat operation" and does not specify the working conditions. Chapter 6, 6.1 of the GK47CE-1 stipulates that "the appliance should meet the requirements of Class II or severe class", and adds "the protection rating of sauna heaters and controllers installed in restricted rooms should be at least IPX4: for ceiling-mounted soft appliances, all electrical components should be at least IPX4", while GK47CE, 31-1 does not contain these contents. Chapter 7.12 of the power supply section adds "the instructions for use of public soft appliances, especially timers, shall specify the method for filling the container"; it also adds "the instructions for use of public soft appliances, especially timers, shall be marketed It should be pointed out that the device must be operated continuously when it is used. The instruction manual of other soft bath heaters should point out that the room should be checked before starting. However, GB47(16.31-1995 does not have this content. Part 7.12.1 of this part adds "Installation instructions for public bath appliances without timers should be indicated. A warning light should be installed in the monitoring to show that the heater is working." GB4755.41-1995 adds this content: Chapter 9 of this part \ Electric belts "Start", this part is not applicable to this state of GB4706.1, GB47CS.3:-106, this chapter of GB4706.1 is applicable". www.bzxz.net
..--This part: 1.7 requires that the device should work until it reaches a certain state, while GB476.311995 stipulates the working hours of heat storage and non-heat storage appliances respectively - this part 11.8 requires that "the environment, walls, floors and ground conditions of the room or prefabricated room should not be forgotten. 15K, while 11. of GB4706.311995 stipulates the surface temperature of "visible or invisible". Part 1.8 of the first car adds "In the room: the temperature of the special handle, shaped handle, gripper and similar parts that are only held for a short time should be increased by 20", while GB47C6.3119S5 does not have this content. 13.2 of GH470.61-199 adds Figure 101, and the leakage protection test that is not carried out according to Figure 101 is also carried out. Except for the "Jun part of the cellar,
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY/T 10012-1998 Specification for naming of offshore oil and gas drilling wells
- SY 5728-1995 Safety Management Regulations for Beach and Sea Oil Seismic Teams
- JB/T 7031-1993 Large mill end cover steel castings
- SJ/T 11043-1996 Test method for high frequency dielectric losses and permittivity of electronic glass
- JB/T 7859-2000 Woven steel cloth with rectangual apertures for rice milling industry
- GB 19112-2003 Rice bran oil
- QB/T 1453-2003 Cable Tray
- JB/T 5054.7-2001 Standardization review of product drawings and design documents
- HG/T 2731-1995 Quality classification of hot alkali pumps
- GB/T 8169-2008 Testing method of vibration transmissibility for packaging cushioning materials
- JB/T 9162.11-1999 Dimensions of knurled set nuts
- GB 18435-2001 Diving breathing gases
- JB/T 2944.1-1996 Vertical universal wood mold milling machine parameters
- JJG 201-2008 Verification Regulation of Tester for Dial Indicator Gauges
- JB/T 7695.2-1995 Type test method for sliding mode cement concrete paver
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com