GB/T 3789.21-1991 Test method for electrical performance of transmitting tubes Test method for reference point of static characteristics
time:
2024-08-10 19:07:33
- GB/T 3789.21-1991
- in force
Standard ID:
GB/T 3789.21-1991
Standard Name:
Test method for electrical performance of transmitting tubes Test method for reference point of static characteristics
Chinese Name:
发射管电性能测试方法 静态特性参考点的测试方法
Standard category:
National Standard (GB)
-
Date of Release:
1991-08-15 -
Date of Implementation:
1992-04-01
Standard ICS number:
Electronics >> 31.100 Electron TubesChina Standard Classification Number:
Electronic Components and Information Technology>>Electro Vacuum Devices>>L35 Electro Vacuum Devices Comprehensive
alternative situation:
Replaces GB 3789.21-1983
Release date:
1983-06-29Review date:
2004-10-14Drafting Organization:
Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry and Factory 799Focal point Organization:
National Technical Committee for Standardization of Vacuum DevicesProposing Organization:
Ministry of Machinery and Electronics Industry of the People's Republic of ChinaPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
Ministry of Information Industry (Electronics)

Skip to download
Summary:
This standard specifies the test method for the reference point of static characteristics of transmitting tubes. This standard is applicable to the test of the reference point of static characteristics of space charge controlled oscillation, modulation, adjustment and power amplifier tubes with anode dissipation power above 25W. GB/T 3789.21-1991 Test method for electrical performance of transmitting tubes Test method for reference point of static characteristics GB/T3789.21-1991 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Test methods of the electrical properties of transmitting tubes
Test methods of static characteristic reference point
Measurenaenta of the electrical properties of tranamitting tubesMeasuaring methods of statlc characteristic reference point1 Subject content and scope of application
This standard specifies the test methods of static characteristic reference point of transmitting tubes. GB/T 3789. 21— 91
Replaces GB3789.21—83
This standard is applicable to the test of static characteristic reference point of space charge controlled oscillation, modulation, adjustment and power amplifier tubes with anode dissipation power above 25W.
2 Reference standards
GB/T3789.1 General principles for the test method of the electrical performance of transmitting tubes GB/T3789.14 Test method for the electrical performance of transmitting tubes Test method for static characteristic curve 3 Terminology
Static characteristic reference point static characteristic tefetence point The static characteristic reference point refers to a point on the electron tube anode current-first gate voltage characteristic curve. This point refers to the first grid voltage value when the anode current reaches the specified value under the electrode voltage state specified in the detailed specification. 4 Power supply schematic
Test equipment and test rules
The test equipment and test rules should comply with the provisions of GB/T3789.1. 6 Test method
6.1 Add the filament voltage and each electrode voltage according to the specification, and add enough negative voltage to the first grid to make the tube under test in the cut-off state. Approved by the State Administration of Technical Supervision on 1991-08-15, implemented on April 1, 1992
GB/T3789.21---91bZxz.net
6.2 Adjust the first grid voltage to make the anode current reach the specified value, and read the first grid voltage value. 6.3 If the anode maximum dissipation power is exceeded or the anode dissipation power is greater than 10kW during the test, the pulse method test in GB/T 3789.14 is allowed.
Additional explanation,
This standard is proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization and Promotion Institute of the Ministry of Machinery and Electronics Industry and Factory 779
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test methods of the electrical properties of transmitting tubes
Test methods of static characteristic reference point
Measurenaenta of the electrical properties of tranamitting tubesMeasuaring methods of statlc characteristic reference point1 Subject content and scope of application
This standard specifies the test methods of static characteristic reference point of transmitting tubes. GB/T 3789. 21— 91
Replaces GB3789.21—83
This standard is applicable to the test of static characteristic reference point of space charge controlled oscillation, modulation, adjustment and power amplifier tubes with anode dissipation power above 25W.
2 Reference standards
GB/T3789.1 General principles for the test method of the electrical performance of transmitting tubes GB/T3789.14 Test method for the electrical performance of transmitting tubes Test method for static characteristic curve 3 Terminology
Static characteristic reference point static characteristic tefetence point The static characteristic reference point refers to a point on the electron tube anode current-first gate voltage characteristic curve. This point refers to the first grid voltage value when the anode current reaches the specified value under the electrode voltage state specified in the detailed specification. 4 Power supply schematic
Test equipment and test rules
The test equipment and test rules should comply with the provisions of GB/T3789.1. 6 Test method
6.1 Add the filament voltage and each electrode voltage according to the specification, and add enough negative voltage to the first grid to make the tube under test in the cut-off state. Approved by the State Administration of Technical Supervision on 1991-08-15, implemented on April 1, 1992
GB/T3789.21---91bZxz.net
6.2 Adjust the first grid voltage to make the anode current reach the specified value, and read the first grid voltage value. 6.3 If the anode maximum dissipation power is exceeded or the anode dissipation power is greater than 10kW during the test, the pulse method test in GB/T 3789.14 is allowed.
Additional explanation,
This standard is proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization and Promotion Institute of the Ministry of Machinery and Electronics Industry and Factory 779
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 15166.5-1994 Fuses for external protection of AC high voltage fuses and parallel capacitors
- JB/T 5884-1991 燃气轮机 控制与保护系统
- GB/T 18925-2002 Skid wooden boxes
- SJ 20694-1998 Ground Radar Maintainability Design Guide
- GB 19158-2003 Compressed natural gas cylinders for station use
- JB/T 7785-1995 Rapid test and evaluation method for the life of low voltage motor insulation structure (step stress method)
- GB/T 39551.2-2020 Patent navigation guide—Part 2:Regional planning
- GB/T 4728.5-2000 Graphical symbols for electrical schematics Part 5: Semiconductor tubes and electron tubes
- SY 5299-1991 Cable-type bridge plug operation procedures
- GB/T 15068-1994 Star anise oil
- YY/T 0340-2002 Basic principles of surgical implants
- HG/T 2353.4-1992 Compatibility test method for filter element for magnetic slurry filtration
- GB/T 16273.5-2002 Graphical symbols for use on equipment--Part 5:Common symbols for plastic machine
- JB/T 7659.2-1995 Water-cooled condenser for Freon refrigeration system
- SJ/T 10545-1994 Blank detail specification for electron gun of black-and white picture tube
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]