GB/T 11433-1989 Dimensions of tube, needle and cylindrical magnetic cores made of magnetic oxides
time:
2024-08-06 12:04:01
- GB/T 11433-1989
- Abolished
Standard ID:
GB/T 11433-1989
Standard Name:
Dimensions of tube, needle and cylindrical magnetic cores made of magnetic oxides
Chinese Name:
磁性氧化物制成的管、针、柱磁芯的尺寸
Standard category:
National Standard (GB)
-
Date of Release:
1989-03-03 -
Date of Implementation:
1990-03-01 -
Date of Expiration:
2005-10-14
Standard ICS number:
Electrical engineering>>Electrical equipment components>>29.100.10 Magnetic componentsChina Standard Classification Number:
Electronic Components and Information Technology >> Electronic Components >> L19 Magnetic Components
Review date:
2004-10-14Drafting Organization:
Shanghai Magnetic Material FactoryFocal point Organization:
National Technical Committee for Standardization of Magnetic Parts and Ferrite MaterialsPublishing Department:
Ministry of Information Industry (Electronics)Competent Authority:
Ministry of Information Industry (Electronics)

Skip to download
Summary:
GB/T 11433-1989 Dimensions of tubes, needles and cylindrical cores made of magnetic oxides GB/T11433-1989 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Dimensions of tubes, pins and rods of ferromagaetic oxides
This standard is equivalent to the dimensions of tubes, pins and rods made of ferromagaetic oxides IE220. 1 Scope and purpose
GB 11433-89
LEC 220
This standard gives information on tubes, pins and rods with a maximum outer diameter of 25 mm (1 in) and a circular cross section. Circular antenna rods and fan antenna rods form a separate standard. 2 Diameter
2.1 Outer diameter
Tubes, pins and rods may be centerless ground or not. For cores that are not centerlessly ground, the tolerance is about ±5% for an outer diameter of about 1 mm (0.04 in) and ±3% for an outer diameter of 10 mm (0.4 in) and above.
For centerless ground cores, the total tolerance for the outside diameter is usually 0.05 mm (0.002 in). Tighter tolerances can be obtained, but additional measurements must be made during the manufacturing process.
2.2 Inside diameter and wall thickness
The inside diameter tolerance is approximately +10% with a minimum value of +0.2 mm to +0.3 mm (0.008 in to +0.012 in). The wall thickness of the core, at its thinnest point, should not be less than 0.2 times the nominal outside diameter. Due to the eccentricity (see 2.3), the inside diameter should not exceed 0.6 times the outside diameter.
The gauge is used to check the eccentricity of the end of the tubular core and the comprehensive deformation caused by the change in size. The dimensions of the gauge are as follows: Note: The other blades of the tubular core should be checked at the specified values. Alternative maximum outer diameter
minimum inner diameter
3 Length
3.1 Centerless ground cores
Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 2, 1989 and implemented on March 1, 1990
GB 11433--89
The length of centerless ground tube, needle and column cores should be between 2 and 10 times the outer diameter. 3.2 Cores cut before firing
The length tolerance of molded cores and extruded cores cut before firing is about ±3% of the length. 3.3 Cores cut after firing
The length tolerance of cores cut after firing can be reduced to ±0.1mm (±0.004in). Attention must be paid to the angle of the core end faces, which can cause the difference in length measured on two opposite sides to reach 10% of the outer diameter. 4 Curvature bzxZ.net
4.1 Curvature value
The curvature is expressed in meters by the maximum deviation of a straight line through the center of the end face. For cores not exceeding 45 mm (1.8 in) in length, the curvature is not greater than 0.2 mm (0.008 in) and is independent of the length. For longer cores not exceeding 80 mm (3.1 in) in length, the maximum curvature corresponds to a circle with a radius of 1250 mm (50 in) and is proportional to the square of the length. For cores longer than 80 mm (3.1 in) the curvature has different directions and is therefore independent of the length. The total curvature of longer cores may be slightly greater than the curvature allowed by the gauge specified in 4.2 for cores longer than 80 mm (3.1 in), but this deviation is usually negligible.
4.2 Gauge for checking curvature
A tubular gauge can be used to check the curvature of the magnetic core. The dimensions of the gauge are as follows: Gauge
Sample length
45 mm(1.8 in)
45~80mm51.8~3.)
≥80 mm(3. lin)
Additional notes:
This standard was drafted by Shanghai Magnetic Material Factory. Length tolerance
±0.05 mm(0.002 0in)
45 mm(1.771 7in)
Sample length
80 mm(3.149 6in)
Inner diameter tolerance
±0.01 mm(0.000 4in)
d maximum value 0.2 mm(0.007 9in)
maximum value + (
a maximum value +0.64 mm(0.025in)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Dimensions of tubes, pins and rods of ferromagaetic oxides
This standard is equivalent to the dimensions of tubes, pins and rods made of ferromagaetic oxides IE220. 1 Scope and purpose
GB 11433-89
LEC 220
This standard gives information on tubes, pins and rods with a maximum outer diameter of 25 mm (1 in) and a circular cross section. Circular antenna rods and fan antenna rods form a separate standard. 2 Diameter
2.1 Outer diameter
Tubes, pins and rods may be centerless ground or not. For cores that are not centerlessly ground, the tolerance is about ±5% for an outer diameter of about 1 mm (0.04 in) and ±3% for an outer diameter of 10 mm (0.4 in) and above.
For centerless ground cores, the total tolerance for the outside diameter is usually 0.05 mm (0.002 in). Tighter tolerances can be obtained, but additional measurements must be made during the manufacturing process.
2.2 Inside diameter and wall thickness
The inside diameter tolerance is approximately +10% with a minimum value of +0.2 mm to +0.3 mm (0.008 in to +0.012 in). The wall thickness of the core, at its thinnest point, should not be less than 0.2 times the nominal outside diameter. Due to the eccentricity (see 2.3), the inside diameter should not exceed 0.6 times the outside diameter.
The gauge is used to check the eccentricity of the end of the tubular core and the comprehensive deformation caused by the change in size. The dimensions of the gauge are as follows: Note: The other blades of the tubular core should be checked at the specified values. Alternative maximum outer diameter
minimum inner diameter
3 Length
3.1 Centerless ground cores
Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 2, 1989 and implemented on March 1, 1990
GB 11433--89
The length of centerless ground tube, needle and column cores should be between 2 and 10 times the outer diameter. 3.2 Cores cut before firing
The length tolerance of molded cores and extruded cores cut before firing is about ±3% of the length. 3.3 Cores cut after firing
The length tolerance of cores cut after firing can be reduced to ±0.1mm (±0.004in). Attention must be paid to the angle of the core end faces, which can cause the difference in length measured on two opposite sides to reach 10% of the outer diameter. 4 Curvature bzxZ.net
4.1 Curvature value
The curvature is expressed in meters by the maximum deviation of a straight line through the center of the end face. For cores not exceeding 45 mm (1.8 in) in length, the curvature is not greater than 0.2 mm (0.008 in) and is independent of the length. For longer cores not exceeding 80 mm (3.1 in) in length, the maximum curvature corresponds to a circle with a radius of 1250 mm (50 in) and is proportional to the square of the length. For cores longer than 80 mm (3.1 in) the curvature has different directions and is therefore independent of the length. The total curvature of longer cores may be slightly greater than the curvature allowed by the gauge specified in 4.2 for cores longer than 80 mm (3.1 in), but this deviation is usually negligible.
4.2 Gauge for checking curvature
A tubular gauge can be used to check the curvature of the magnetic core. The dimensions of the gauge are as follows: Gauge
Sample length
45 mm(1.8 in)
45~80mm51.8~3.)
≥80 mm(3. lin)
Additional notes:
This standard was drafted by Shanghai Magnetic Material Factory. Length tolerance
±0.05 mm(0.002 0in)
45 mm(1.771 7in)
Sample length
80 mm(3.149 6in)
Inner diameter tolerance
±0.01 mm(0.000 4in)
d maximum value 0.2 mm(0.007 9in)
maximum value + (
a maximum value +0.64 mm(0.025in)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 17696-1999 Acoustics--Audiometric test methods--Part 3:Speech audiometry
- GB/T 19816.5-2005 Preparation of steel substrates before application of paints and related products—Test methods for metallic blast-cleaning abrasives—Part5:Determination of percentage defective particles and of microstructure
- GB/T 3668.3-1983 Dimensions of rotary tables and polygonal intermediate bases for rotary tables, common components of modular machine tools
- JB/T 5066-1991 Reference model for production standards of automated workshops in manufacturing industry
- QB/T 2556-2002 Design regulations for cast iron drying cylinders for papermaking machinery
- HG/T 2133-1991 Glass-lined 60° elbow
- JB/T 2001.20-1999 Water system centralized air release valve core (PN=31.5MPa)
- SJ 20813-2002 Specification for chemical conversion on aluminum and aluminum alloys
- QB/T 1578-1992 Industrial sewing machine GC type lockstitch sewing machine push plate
- HG 2262-1992 Technical Specifications for Single-stage Cantilever Double-acting Liquid Ring Chlorine Pumps
- GB 19456-2004 Safety specification for inspection of hazardous properties of dangerous goods such as nitrates
- GB 1094.5-1985 Power transformers Part 5 Short circuit capability
- GB/T 3214-1991 Method for determination of pump flow rate
- GB/T 5448-1997 Determination of crucible expansion number of bituminous coal - Electric heating method
- GBJ 39-1990 Code for fire protection design of rural buildings
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com