
GB/T 3789.12-1991 Test methods for electrical properties of transmitting tubes Test methods for inter-electrode insulation
time:
2024-08-10 19:13:55
- GB/T 3789.12-1991
- in force
Standard ID:
GB/T 3789.12-1991
Standard Name:
Test methods for electrical properties of transmitting tubes Test methods for inter-electrode insulation
Chinese Name:
发射管电性能测试方法 极间绝缘的测试方法
Standard category:
National Standard (GB)
-
Date of Release:
1991-08-15 -
Date of Implementation:
1992-04-01
Standard ICS number:
Electronics >> 31.100 Electron TubesChina Standard Classification Number:
Electronic Components and Information Technology>>Electro Vacuum Devices>>L35 Electro Vacuum Devices Comprehensive
alternative situation:
Replaces GB 3789.12-1983
Release date:
1983-06-29Review date:
2004-10-14Drafting Organization:
Electronic Standardization Institute and Factory 779 of the Ministry of Machinery and Electronics IndustryFocal point Organization:
National Technical Committee for Standardization of Vacuum DevicesProposing Organization:
Ministry of Machinery and Electronics Industry of the People's Republic of ChinaPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
Ministry of Information Industry (Electronics)

Skip to download
Summary:
This standard specifies the test method for the inter-electrode insulation of transmitting tubes - inter-electrode leakage current or inter-electrode insulation resistance. This standard is applicable to the test of inter-electrode insulation of space charge controlled oscillation, modulation, adjustment and power amplifier tubes with anode dissipation power above 25W. GB/T 3789.12-1991 Test method for electrical properties of transmitting tubes Test method for inter-electrode insulation GB/T3789.12-1991 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Test methods for electrical properties of transmitting tubes
Test methods for interelectrode insulation
Measurements of the electrical properties of trarismitting hubesMeasuring methods of interelectrode insulationSubject content and scope of application
This standard specifies the test methods for interelectrode insulation of transmitting tubes -
interelectrode leakage current or interelectrode insulation resistance
GB/T 3789. 1291Www.bzxZ.net
Replaces GB3789.12-83
This standard is applicable to the test of interelectrode insulation of space charge controlled oscillation, modulation, regulation and power amplifier tubes with anode dissipation power of more than 25W.
2 Reference standards
General principles for testing the electrical properties of transmitting tubes
GB/T 3789. 1
3 Terms
3.1 Interelectrode leakage current (insulation current) Interelectrode leakage current refers to the conduction current that flows between two or more electrodes in any way (except the current flowing through the vacuum gap between electrodes) under the specified working conditions. 3.2 Interelectrode insulation resistance The ohm value that indicates the degree of insulation between electrodes. 4 Electrical schematics
5 Test equipment and test rules
The test equipment and test rules shall comply with the provisions of GB/T3789.1. 6 Test methods
6.1 Connect the electrodes to be tested to the A and B terminals, and the other electrodes are disconnected. Add voltage (the voltage value is specified in the product standard. If there is no specification, it should be 500V). At this time, the indication value of the Huian meter is the leakage current (or the scale is the insulation resistance value). If the polarity of the applied voltage is not specified, the test should be carried out under two polarities (that is, under the two positions of the conversion switch). And read the smaller resistance value (or the larger current value) as the test result.
6.2 When testing the insulation resistance between the cathode and the filament, it must be carried out when the cathode is heated and the other electrodes are disconnected. If the preheating time is not specified in the product standard, it should be 3min. When testing the insulation resistance between the cathode and other electrodes, if the filament is in the heated state, only the cathode is allowed to be at a positive potential.
Additional Notes:
This standard is proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry and Factory 779.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test methods for electrical properties of transmitting tubes
Test methods for interelectrode insulation
Measurements of the electrical properties of trarismitting hubesMeasuring methods of interelectrode insulationSubject content and scope of application
This standard specifies the test methods for interelectrode insulation of transmitting tubes -
interelectrode leakage current or interelectrode insulation resistance
GB/T 3789. 1291Www.bzxZ.net
Replaces GB3789.12-83
This standard is applicable to the test of interelectrode insulation of space charge controlled oscillation, modulation, regulation and power amplifier tubes with anode dissipation power of more than 25W.
2 Reference standards
General principles for testing the electrical properties of transmitting tubes
GB/T 3789. 1
3 Terms
3.1 Interelectrode leakage current (insulation current) Interelectrode leakage current refers to the conduction current that flows between two or more electrodes in any way (except the current flowing through the vacuum gap between electrodes) under the specified working conditions. 3.2 Interelectrode insulation resistance The ohm value that indicates the degree of insulation between electrodes. 4 Electrical schematics
5 Test equipment and test rules
The test equipment and test rules shall comply with the provisions of GB/T3789.1. 6 Test methods
6.1 Connect the electrodes to be tested to the A and B terminals, and the other electrodes are disconnected. Add voltage (the voltage value is specified in the product standard. If there is no specification, it should be 500V). At this time, the indication value of the Huian meter is the leakage current (or the scale is the insulation resistance value). If the polarity of the applied voltage is not specified, the test should be carried out under two polarities (that is, under the two positions of the conversion switch). And read the smaller resistance value (or the larger current value) as the test result.
6.2 When testing the insulation resistance between the cathode and the filament, it must be carried out when the cathode is heated and the other electrodes are disconnected. If the preheating time is not specified in the product standard, it should be 3min. When testing the insulation resistance between the cathode and other electrodes, if the filament is in the heated state, only the cathode is allowed to be at a positive potential.
Additional Notes:
This standard is proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry and Factory 779.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 4678.14-2003 Die casting parts Part 14: Stop pins
- LB/T 004-2013 Specification for domestic tour service by travel service
- JB/T 10395-2004 Off-grid wind turbine installation specification
- JB/T 50171-1999 Energy consumption classification of ceramic abrasive kilns
- GB/T 15649-1995 Blank detail specification for semiconductor laser diodes
- GB/T 11361-1989 Synchronous belt drive pulleys
- GB/T 14598.6-1993 Electrical relays Part 18: Dimensions of general purpose relays with or without
- HG 3129-1998 Integral multi-layer clamping high pressure vessel
- GB/T 14539.4-1993 Determination of lead in compound fertilizers
- GB/T 21601-2008 Dangerous goods - Test method for bale handle and drop handle strength of packaging
- JB/T 7044-1993 Test methods for hydraulic axial piston pumps
- GB/T 15904-1995 Determination of polyisoprene content in rubber
- GB 4706.34-2003 Safety of household and similar electrical appliances Particular requirements for commercial electric forced convection ovens, steam cookers and steam convection ovens
- JB/T 10000-1999 55° tapered pipe thread rolling wheel
- GB/T 5059.5-1986 Chemical analysis methods for ferromolybdenum - Gravimetric method for determination of silicon content
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com