GB/T 5660-1985 Dimensions of the base and installation of axial suction centrifugal pumps
time:
2024-08-04 14:35:31
- GB/T 5660-1985
- in force
Standard ID:
GB/T 5660-1985
Standard Name:
Dimensions of the base and installation of axial suction centrifugal pumps
Chinese Name:
轴向吸入离心泵底座尺寸和安装尺寸
Standard category:
National Standard (GB)
-
Date of Release:
1985-01-01 -
Date of Implementation:
1986-09-01
Standard ICS number:
Fluid Systems and General Parts >> 23.080 PumpsChina Standard Classification Number:
Machinery>>General Machinery and Equipment>>J71 Pump
Release date:
1985-11-25Review date:
2004-10-14Drafting Organization:
Shenyang Pump InstituteFocal point Organization:
National Pump Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Machinery Industry Federation

Skip to download
Summary:
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to adapt to various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. GB/T 5660-1985 Dimensions of base and installation dimensions of axial suction centrifugal pumps GB/T5660-1985 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Axial Suction Centrifugal Pumps
Baseplate and Installatlon Dimensions
UDC 621.6T
GB 5660--85
1S0 3661-1977
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to be suitable for various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. This standard is mainly applicable to the connection dimensions of axial suction centrifugal pumps that meet GB5662-85 "Marking, Performance and Dimensions of Axial Suction Centrifugal Pumps (16bar)" and motors with base feet. The motor size should comply with the provisions of JB3074-82 "Technical Conditions for Y Series (IP44) Three-Phase Asynchronous Motors (H80~280mm)". Other types of pumps may also adopt this standard if appropriate. This standard is equivalent to the international standard IS036611977 "Axial suction centrifugal pump base dimensions and installation dimensions". The base number and dimensions shall comply with the provisions of the figure and Table 1. The basic installation dimensions shall comply with the provisions of Table 2. The base size is found from Table 2 according to the pump size mark and the corresponding motor base number. Then, the size of the base number is found from Table 1. Table 1 Base number and size
Base number
L,±25
d*Hole screw control
Properties: The dimensions L, and B, in the table are respectively! The length and width of the working area, excluding casting deviations. * According to the provisions of the rough assembly bolts in GB15276 "Fastener through hole countersunk head seat size". National Bureau of Standards 1986-11-25 Issued 7
1986-09-01 Implementation
GB 5660-85
Basic dimensions of base and installation
Working area City L, xB,
Note: ① m is the maximum allowable height of the base, which includes the thickness of the gasket that may be placed between the base and the pump motor. The actual height can be less than this value.
② The dimensions mx and m do not include additional bottom structural parts, such as the height of the foot of an independent device, the alarm, etc. ③ The positions of five holes (A, B, C, D, E) are marked in the figure. The base can also have four (A, B, C, D) or three holes (A, C, E), which is determined by the pump manufacturer.
Pump size marking"
150315
GB 5660B5
Sleeping seat number and installation size selection
160180180
Basic installation sizewww.bzxz.net
:①H in the table is the maximum allowable height, and the actual size + H can be less than this value. When giving the Hmx value of each size pump, the following is taken into account. According to GB 5662-85.
** According to JB 3074.
GB5660-85
The maximum height of the largest base equipped with the pump and the centerline height of the pump or motor (the centerline height takes the larger value of the two)②The left side of the thick line in the table is that the centerline of the pump is higher than the centerline of the motor, and the right side is that the centerline of the motor is higher than the centerline of the pump. This standard was drafted by the Machinery of the People's Republic of China
This standard was drafted by the Shenyang Pump Research Institute. The drafter of this standard is Huang Yuying.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Axial Suction Centrifugal Pumps
Baseplate and Installatlon Dimensions
UDC 621.6T
GB 5660--85
1S0 3661-1977
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to be suitable for various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. This standard is mainly applicable to the connection dimensions of axial suction centrifugal pumps that meet GB5662-85 "Marking, Performance and Dimensions of Axial Suction Centrifugal Pumps (16bar)" and motors with base feet. The motor size should comply with the provisions of JB3074-82 "Technical Conditions for Y Series (IP44) Three-Phase Asynchronous Motors (H80~280mm)". Other types of pumps may also adopt this standard if appropriate. This standard is equivalent to the international standard IS036611977 "Axial suction centrifugal pump base dimensions and installation dimensions". The base number and dimensions shall comply with the provisions of the figure and Table 1. The basic installation dimensions shall comply with the provisions of Table 2. The base size is found from Table 2 according to the pump size mark and the corresponding motor base number. Then, the size of the base number is found from Table 1. Table 1 Base number and size
Base number
L,±25
d*Hole screw control
Properties: The dimensions L, and B, in the table are respectively! The length and width of the working area, excluding casting deviations. * According to the provisions of the rough assembly bolts in GB15276 "Fastener through hole countersunk head seat size". National Bureau of Standards 1986-11-25 Issued 7
1986-09-01 Implementation
GB 5660-85
Basic dimensions of base and installation
Working area City L, xB,
Note: ① m is the maximum allowable height of the base, which includes the thickness of the gasket that may be placed between the base and the pump motor. The actual height can be less than this value.
② The dimensions mx and m do not include additional bottom structural parts, such as the height of the foot of an independent device, the alarm, etc. ③ The positions of five holes (A, B, C, D, E) are marked in the figure. The base can also have four (A, B, C, D) or three holes (A, C, E), which is determined by the pump manufacturer.
Pump size marking"
150315
GB 5660B5
Sleeping seat number and installation size selection
160180180
Basic installation sizewww.bzxz.net
:①H in the table is the maximum allowable height, and the actual size + H can be less than this value. When giving the Hmx value of each size pump, the following is taken into account. According to GB 5662-85.
** According to JB 3074.
GB5660-85
The maximum height of the largest base equipped with the pump and the centerline height of the pump or motor (the centerline height takes the larger value of the two)②The left side of the thick line in the table is that the centerline of the pump is higher than the centerline of the motor, and the right side is that the centerline of the motor is higher than the centerline of the pump. This standard was drafted by the Machinery of the People's Republic of China
This standard was drafted by the Shenyang Pump Research Institute. The drafter of this standard is Huang Yuying.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 1050-1993 Single-stage double-suction clean water centrifugal pump types and basic parameters
- JB/T 5867-1991 General technical requirements for coreless armature permanent magnet DC servo motors
- SY/T 0450-1997 Specification for seismic design of buried steel pipelines for oil (gas) transportation
- GB/T 3251-1982 Compression test method for aluminum and aluminum alloy pipes
- GB 4761-1984 Codes for family relationship
- GB 11626-1989 Rescue boat winch
- GB 5100-1994 Steel welded gas cylinders
- CB* 3299-1987 Calculation method for load-bearing capacity of involute cylindrical gears for ships
- JB/T 6990-2002 MP type roller disc coal mill
- CJ/T 3003-1993 Technical conditions for taxi operation
- GB 17583-1998 Porous granular ammonium fuel oil explosive
- GB/T 21785-2008 Laboratory glassware - Pyknometers
- GB/T 2424.22-1986 Basic environmental test procedures for electrical and electronic products - Guidelines for comprehensive tests on temperature (low temperature, high temperature) and vibration (sinusoidal)
- GB/T 4549.2-2004 Vocabulary of railway vehicles Part 2: Running gear
- HG/T 3487-2000 Chemical reagents: dipotassium hydrogen phosphate