GB/T 5660-1985 Dimensions of the base and installation of axial suction centrifugal pumps
time:
2024-08-04 14:35:31
- GB/T 5660-1985
- in force
Standard ID:
GB/T 5660-1985
Standard Name:
Dimensions of the base and installation of axial suction centrifugal pumps
Chinese Name:
轴向吸入离心泵底座尺寸和安装尺寸
Standard category:
National Standard (GB)
-
Date of Release:
1985-01-01 -
Date of Implementation:
1986-09-01
Standard ICS number:
Fluid Systems and General Parts >> 23.080 PumpsChina Standard Classification Number:
Machinery>>General Machinery and Equipment>>J71 Pump
Release date:
1985-11-25Review date:
2004-10-14Drafting Organization:
Shenyang Pump InstituteFocal point Organization:
National Pump Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Machinery Industry Federation
Skip to download
Summary:
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to adapt to various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. GB/T 5660-1985 Dimensions of base and installation dimensions of axial suction centrifugal pumps GB/T5660-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Axial Suction Centrifugal Pumps
Baseplate and Installatlon DimensionswwW.bzxz.Net
UDC 621.6T
GB 5660--85
1S0 3661-1977
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to be suitable for various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. This standard is mainly applicable to the connection dimensions of axial suction centrifugal pumps that meet GB5662-85 "Marking, Performance and Dimensions of Axial Suction Centrifugal Pumps (16bar)" and motors with base feet. The motor size should comply with the provisions of JB3074-82 "Technical Conditions for Y Series (IP44) Three-Phase Asynchronous Motors (H80~280mm)". Other types of pumps may also adopt this standard if appropriate. This standard is equivalent to the international standard IS036611977 "Axial suction centrifugal pump base dimensions and installation dimensions". The base number and dimensions shall comply with the provisions of the figure and Table 1. The basic installation dimensions shall comply with the provisions of Table 2. The base size is found from Table 2 according to the pump size mark and the corresponding motor base number. Then, the size of the base number is found from Table 1. Table 1 Base number and size
Base number
L,±25
d*Hole screw control
Properties: The dimensions L, and B, in the table are respectively! The length and width of the working area, excluding casting deviations. * According to the provisions of the rough assembly bolts in GB15276 "Fastener through hole countersunk head seat size". National Bureau of Standards 1986-11-25 Issued 7
1986-09-01 Implementation
GB 5660-85
Basic dimensions of base and installation
Working area City L, xB,
Note: ① m is the maximum allowable height of the base, which includes the thickness of the gasket that may be placed between the base and the pump motor. The actual height can be less than this value.
② The dimensions mx and m do not include additional bottom structural parts, such as the height of the foot of an independent device, the alarm, etc. ③ The positions of five holes (A, B, C, D, E) are marked in the figure. The base can also have four (A, B, C, D) or three holes (A, C, E), which is determined by the pump manufacturer.
Pump size marking"
150315
GB 5660B5
Sleeping seat number and installation size selection
160180180
Basic installation size
:①H in the table is the maximum allowable height, and the actual size + H can be less than this value. When giving the Hmx value of each size pump, the following is taken into account. According to GB 5662-85.
** According to JB 3074.
GB5660-85
The maximum height of the largest base equipped with the pump and the centerline height of the pump or motor (the centerline height takes the larger value of the two)②The left side of the thick line in the table is that the centerline of the pump is higher than the centerline of the motor, and the right side is that the centerline of the motor is higher than the centerline of the pump. This standard was drafted by the Machinery of the People's Republic of China
This standard was drafted by the Shenyang Pump Research Institute. The drafter of this standard is Huang Yuying.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Axial Suction Centrifugal Pumps
Baseplate and Installatlon DimensionswwW.bzxz.Net
UDC 621.6T
GB 5660--85
1S0 3661-1977
This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to be suitable for various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. This standard is mainly applicable to the connection dimensions of axial suction centrifugal pumps that meet GB5662-85 "Marking, Performance and Dimensions of Axial Suction Centrifugal Pumps (16bar)" and motors with base feet. The motor size should comply with the provisions of JB3074-82 "Technical Conditions for Y Series (IP44) Three-Phase Asynchronous Motors (H80~280mm)". Other types of pumps may also adopt this standard if appropriate. This standard is equivalent to the international standard IS036611977 "Axial suction centrifugal pump base dimensions and installation dimensions". The base number and dimensions shall comply with the provisions of the figure and Table 1. The basic installation dimensions shall comply with the provisions of Table 2. The base size is found from Table 2 according to the pump size mark and the corresponding motor base number. Then, the size of the base number is found from Table 1. Table 1 Base number and size
Base number
L,±25
d*Hole screw control
Properties: The dimensions L, and B, in the table are respectively! The length and width of the working area, excluding casting deviations. * According to the provisions of the rough assembly bolts in GB15276 "Fastener through hole countersunk head seat size". National Bureau of Standards 1986-11-25 Issued 7
1986-09-01 Implementation
GB 5660-85
Basic dimensions of base and installation
Working area City L, xB,
Note: ① m is the maximum allowable height of the base, which includes the thickness of the gasket that may be placed between the base and the pump motor. The actual height can be less than this value.
② The dimensions mx and m do not include additional bottom structural parts, such as the height of the foot of an independent device, the alarm, etc. ③ The positions of five holes (A, B, C, D, E) are marked in the figure. The base can also have four (A, B, C, D) or three holes (A, C, E), which is determined by the pump manufacturer.
Pump size marking"
150315
GB 5660B5
Sleeping seat number and installation size selection
160180180
Basic installation size
:①H in the table is the maximum allowable height, and the actual size + H can be less than this value. When giving the Hmx value of each size pump, the following is taken into account. According to GB 5662-85.
** According to JB 3074.
GB5660-85
The maximum height of the largest base equipped with the pump and the centerline height of the pump or motor (the centerline height takes the larger value of the two)②The left side of the thick line in the table is that the centerline of the pump is higher than the centerline of the motor, and the right side is that the centerline of the motor is higher than the centerline of the pump. This standard was drafted by the Machinery of the People's Republic of China
This standard was drafted by the Shenyang Pump Research Institute. The drafter of this standard is Huang Yuying.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 5211.6-1985 Determination of acid resistance of pigments
- CJ/T 3003-1993 Technical conditions for taxi operation
- GB 7256.1-1987 General requirements for technical conditions of civil airport lighting fixtures
- HG/T 3611-1999 Test method for simulated walking (life) of footwear
- JB/T 7236-2001 Technical requirements for three-wheeled agricultural transport vehicles
- CB/Z 134-1998 Technical requirements for processing of submarine pressure hull structural parts
- GB/T 4842-1995 Argon
- GB/T 4549.7-1984 Terminology of heating, ventilation and air conditioning equipment for railway vehicles
- GB/T 9107-1999 Refined cotton
- JB/T 2944.1-1996 Vertical universal wood mold milling machine parameters
- GB/T 14393-1993 Location of codes in trade documents
- GB/T 14678-1993 Air quality - Determination of hydrogen sulfide, methyl mercaptan, methyl sulfide and dimethyl disulfide - Gas chromatography
- LS/T 1712-2004 Classification and codes of grain information--Classification and codes of grain trade statistics
- JB/T 5678-1991 Technical requirements for fluidized bed tea drying machine
- GB 17353-1998 Steering lock anti-theft devices for motorcycles and mopeds
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com