
HG 2957.10-1984 Determination of total iron content in alum ore - Sulfosalicylic acid photometric method
time:
2024-08-14 08:05:50
- HG 2957.10-1984
- in force
Standard ID:
HG 2957.10-1984
Standard Name:
Determination of total iron content in alum ore - Sulfosalicylic acid photometric method
Chinese Name:
明矾石矿石全铁量的测定 磺基水杨酸光度法
Standard category:
Chemical industry standards (HG)
alternative situation:
GB 4581.10-84; HG 1-353-66

Skip to download
Summary:
HG 2957.10-1984 Determination of total iron content in alum stone ore Sulfosalicylic acid photometric method HG2957.10-1984 standard download decompression password: www.bzxz.net

Some standard content:
Scope of application
National Standard of the People's Republic of China
Alunite ores-Determination of total iron content--Sulphosalicylic acld photometric methodUDC 549.762:543
-42 : 546.72
GB4581.10-84
This standard specifies the determination of 10.10~10.00% iron oxide content in alunite ores by sulfosalicylic acid complex photometric method. 2Related standards
GB4581.1-84 "General rules for analysis of alunite ores". GB4581.2-84 "Methods for taking and preparing analysis samples of alunite ores". 3 Method Summary
The sample is melted with sodium hydroxide and sodium peroxide, and then acidified after leaching in water. In an ammonia medium with a pH of 8.5 to 11.8, iron ions form a yellow complex with sulfosalicylic acid. At a wavelength of 430 nanometers, the gram molecular absorption coefficient is 5.32×10, and iron oxide conforms to Beer's law in the range of 0 to 0.9 mg/100 ml.
4 Instrument
Spectrophotometer: 430 nanometers in length, 1 cm colorimetric blood. 5 Reagents and solutions
5.1 Sodium hydroxide (GB 629-81).
5.2 Sodium peroxide.
5.3 Hydrochloric acid (GB622-77) (specific gravity 1.19). 5.4 Nitric acid (GB 626-78) (specific gravity 1.42), 5.5bzxz.net
Ammonia water (GB631-77) (specific gravity 0.90): 1+15.6Sulfosalicylic acid (HG3-991-81): 25% (filtered and placed in brown bottle). 5.7
Iron wire.
5.B Iron standard solution
5.8.1 Weigh 1.4297 g of iron wire (5.7) and place it in a 150 ml beaker 1, add 20 ml of aqua regia, and heat to dissolve. After cooling, transfer to a 1000 ml volumetric flask, dilute to the mark with water, and shake to make a hook. This solution contains iron oxide per ml 1.000 mg. 5.8.2 Pipette 100 ml of the free solution (5.8.1) into a 1000 ml volumetric flask, dilute to the mark with water, and shake well. This solution contains 0.1000 mg of iron oxide per ml. 6 Determination procedures
6.1 Drawing of standard curve
Use a microburette to place 0, 1.00, 2.00, 3.00, ...··9.00 ml of the iron standard solution (5.8.2) into a 100 ml volumetric flask. Issued by the National Bureau of Standards on July 20, 1984
. Implemented on June 1, 1985
GB 4581.10.--84
Into each volumetric flask, add 12 ml of salicylic acid solution (5.6) and shake for about 10 minutes. Add ammonia solution (5.5) drop by drop until the solution turns yellow and no longer darkens, then add 10 ml. Dilute with water to the scale, shake, and measure the extinction value with a 1 cm colorimetric scale at a wavelength of 430 nm on a spectrophotometer. Use the concentration of iron oxide as the horizontal axis and the corresponding extinction value as the vertical axis to draw a standard curve. 6.2 Sample analysis
Weigh 0.2-0.5 g of sample silver, add a small amount of anhydrous ethanol to wet the sample, add 4 g of sodium hydroxide (5.1), and then cover with 0.5 g of sodium peroxide (5.2), place in a muffle furnace, heat from low temperature to 700°C, melt for 15 minutes, take out and cool, put in a 150 ml beaker, add 50 ml of hot water, cover the surface with blood, heat the molten block, and use hot water Wash out the crucible. Add 15 ml of hydrochloric acid solution (5.3) and boil for 15 minutes. Remove and cool, transfer to a 250 ml volumetric flask, dilute with water to the mark, and shake. Dry filter. Pipette 10-50 ml of the filtrate into a 100 ml volumetric flask, and the following operations are the same as the drawing of the standard curve (6.1). 7 Expression and calculation of results
The percentage content (xin) of iron oxide (Fez (3) is calculated according to the following formula: V
×10-3
Where: G1--heavy oxygen content of iron oxide in the sample solution found on the standard curve, g; -total volume of the measured solution, ml,
V-volume of the sample solution, ml
W-weight of the sample, g.
8 Tolerance
Fe content, %
0.10~t.00
1.01 -- 10,00
Additional Notes:
Diameter tolerance (absolute value), %
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Chemical Industry Research Institute of the Ministry of Chemical Industry, and the main author of this standard is Cheng Maomei.
From the time this standard is implemented, the original Ministry of Chemical Industry standard HG1-353-66 "Uniform Analysis Method of Alum Stone" will be invalid. 23
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
Alunite ores-Determination of total iron content--Sulphosalicylic acld photometric methodUDC 549.762:543
-42 : 546.72
GB4581.10-84
This standard specifies the determination of 10.10~10.00% iron oxide content in alunite ores by sulfosalicylic acid complex photometric method. 2Related standards
GB4581.1-84 "General rules for analysis of alunite ores". GB4581.2-84 "Methods for taking and preparing analysis samples of alunite ores". 3 Method Summary
The sample is melted with sodium hydroxide and sodium peroxide, and then acidified after leaching in water. In an ammonia medium with a pH of 8.5 to 11.8, iron ions form a yellow complex with sulfosalicylic acid. At a wavelength of 430 nanometers, the gram molecular absorption coefficient is 5.32×10, and iron oxide conforms to Beer's law in the range of 0 to 0.9 mg/100 ml.
4 Instrument
Spectrophotometer: 430 nanometers in length, 1 cm colorimetric blood. 5 Reagents and solutions
5.1 Sodium hydroxide (GB 629-81).
5.2 Sodium peroxide.
5.3 Hydrochloric acid (GB622-77) (specific gravity 1.19). 5.4 Nitric acid (GB 626-78) (specific gravity 1.42), 5.5bzxz.net
Ammonia water (GB631-77) (specific gravity 0.90): 1+15.6Sulfosalicylic acid (HG3-991-81): 25% (filtered and placed in brown bottle). 5.7
Iron wire.
5.B Iron standard solution
5.8.1 Weigh 1.4297 g of iron wire (5.7) and place it in a 150 ml beaker 1, add 20 ml of aqua regia, and heat to dissolve. After cooling, transfer to a 1000 ml volumetric flask, dilute to the mark with water, and shake to make a hook. This solution contains iron oxide per ml 1.000 mg. 5.8.2 Pipette 100 ml of the free solution (5.8.1) into a 1000 ml volumetric flask, dilute to the mark with water, and shake well. This solution contains 0.1000 mg of iron oxide per ml. 6 Determination procedures
6.1 Drawing of standard curve
Use a microburette to place 0, 1.00, 2.00, 3.00, ...··9.00 ml of the iron standard solution (5.8.2) into a 100 ml volumetric flask. Issued by the National Bureau of Standards on July 20, 1984
. Implemented on June 1, 1985
GB 4581.10.--84
Into each volumetric flask, add 12 ml of salicylic acid solution (5.6) and shake for about 10 minutes. Add ammonia solution (5.5) drop by drop until the solution turns yellow and no longer darkens, then add 10 ml. Dilute with water to the scale, shake, and measure the extinction value with a 1 cm colorimetric scale at a wavelength of 430 nm on a spectrophotometer. Use the concentration of iron oxide as the horizontal axis and the corresponding extinction value as the vertical axis to draw a standard curve. 6.2 Sample analysis
Weigh 0.2-0.5 g of sample silver, add a small amount of anhydrous ethanol to wet the sample, add 4 g of sodium hydroxide (5.1), and then cover with 0.5 g of sodium peroxide (5.2), place in a muffle furnace, heat from low temperature to 700°C, melt for 15 minutes, take out and cool, put in a 150 ml beaker, add 50 ml of hot water, cover the surface with blood, heat the molten block, and use hot water Wash out the crucible. Add 15 ml of hydrochloric acid solution (5.3) and boil for 15 minutes. Remove and cool, transfer to a 250 ml volumetric flask, dilute with water to the mark, and shake. Dry filter. Pipette 10-50 ml of the filtrate into a 100 ml volumetric flask, and the following operations are the same as the drawing of the standard curve (6.1). 7 Expression and calculation of results
The percentage content (xin) of iron oxide (Fez (3) is calculated according to the following formula: V
×10-3
Where: G1--heavy oxygen content of iron oxide in the sample solution found on the standard curve, g; -total volume of the measured solution, ml,
V-volume of the sample solution, ml
W-weight of the sample, g.
8 Tolerance
Fe content, %
0.10~t.00
1.01 -- 10,00
Additional Notes:
Diameter tolerance (absolute value), %
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Chemical Industry Research Institute of the Ministry of Chemical Industry, and the main author of this standard is Cheng Maomei.
From the time this standard is implemented, the original Ministry of Chemical Industry standard HG1-353-66 "Uniform Analysis Method of Alum Stone" will be invalid. 23
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG 20235-1993 Construction Organization Design Standard for Chemical Engineering Projects
- GB 12708-1991 Navigation light signal colors
- GB/T 2423.42-1995 Environmental testing for electrical and electronic products - Low temperature/low pressure/vibration (sinusoidal) comprehensive test method
- GB/T 5860-2003 液压快换接头 尺寸和要求
- GB/T 4798.7-1987 Environmental conditions for application of electrical and electronic products - Portable and non-stationary use
- JB/T 6914-1993 Automobile air conditioner performance test method
- GB/T 15828-1995 V-belt and multi-V belt drive--Dynamic determination of pitch line position
- GB/T 3873-1983 General technical requirements for packaging of communication equipment products
- GB 5197.2-1996 Glass infusion bottle caps Part 2: Aluminum-plastic combination caps
- JB/T 6705-1993 Technical specifications for starter one-way clutch for tractors and internal combustion engines
- GB/T 5627.1-1985 Expanded taper thread long pipe joints
- JJG 2043-1989 Measuring Instrumentsfor Exposure of 60~250kVX-Ray (Radiotherapy Level)
- SL 55-2005 Specification for geological investigation of small and medium-sized water conservancy and hydropower projects
- JB/T 3711.3-1999 Technical quantities and units of centralized lubrication systems
- GB/T 3880-1997 Aluminium and aluminium alloy rolled plates
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com