JB/T 2001.35-1999 Water system check valve (PN=20MPa)
time:
2024-08-14 13:34:35
- JB/T 2001.35-1999
- in force
Standard ID:
JB/T 2001.35-1999
Standard Name:
Water system check valve (PN=20MPa)
Chinese Name:
水系统 单向阀(PN=20MPa)
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-06-28 -
Date of Implementation:
2000-01-01
Standard ICS number:
Fluid systems and general parts >> 23.100 Fluid power systemsChina Standard Classification Number:
Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices
alternative situation:
JB 2035-1984
Focal point Organization:
Metallurgical Equipment Standardization Technical Committee

Skip to download
Summary:
JB/T 2001.35-1999 JB/T 2001.35-1999 Water system non-return valve (PN=20MPa) JB/T2001.35-1999 Standard download decompression password: www.bzxz.net

Some standard content:
IC.s$ 23.110
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
1Boyin
Machinery Industry Standard of the People's Republic of China
Water system check valve
Waller sstem-Cherk valve
( PN=20 MPa )
This standard specifies the type, size and technical requirements of single-chamber pipes. This standard is suitable for single-chamber pipes used alone in liquid pipelines with a nominal pressure of 2UMPL. 2 Referenced standards
JB/2001.35—1999
Reference 235-84
The provisions contained in the following standards become the provisions of this standard through reference in 4 standards. They are not published as standards. The versions shown are all valid and will be revised by the relevant standard department. All parties using this standard should discuss the possibility of using the new version of the following standards: JB/20U1.33—9 Water System Single Core (PN-20, 3!5M Pa) B2001.34—[999 water system one-way, PN-31MPa] 3 Types and dimensions
3.1 The type and dimensions of D32mm shall be in accordance with the specifications of JB/200E.34.1. 3.2 The type and dimensions of DN40-50mm shall be in accordance with the provisions of Figure 1 and Table 1, 3.3 The type and dimensions of DN65-100mm shall be in accordance with the provisions of Figure 2 and Table 1. M1
1-Flange type one-way valve core: 2-Valve body, 3-Flange after force attachment
Approved by the National Machinery Industry Bureau on 1599-06-28
Implementation on 2000-01-01
JB:T 20O1.35.2
JB/T 2001.35.3
JT 2GO1.35.4
JE2o1.35.5
4Technical requirements
1:4 x 14
40×18
J8/2001.35-1999
One flange type single flash core: 2—idle body, 3—internal secretion*Figure 2
4.1 Nominal pressure 20MPa, test force 30MPa16s :
Installation details
4.2 The valve body and the core are pressure tested together to check the limit of the valve and the performance of the seal. The test method is in accordance with the technical requirements of J/T200t.33. 5 Marking examplebzxz.net
One-way valve with a nominal diameter of 40mm:
One-way DN40B/T200135—1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
1Boyin
Machinery Industry Standard of the People's Republic of China
Water system check valve
Waller sstem-Cherk valve
( PN=20 MPa )
This standard specifies the type, size and technical requirements of single-chamber pipes. This standard is suitable for single-chamber pipes used alone in liquid pipelines with a nominal pressure of 2UMPL. 2 Referenced standards
JB/2001.35—1999
Reference 235-84
The provisions contained in the following standards become the provisions of this standard through reference in 4 standards. They are not published as standards. The versions shown are all valid and will be revised by the relevant standard department. All parties using this standard should discuss the possibility of using the new version of the following standards: JB/20U1.33—9 Water System Single Core (PN-20, 3!5M Pa) B2001.34—[999 water system one-way, PN-31MPa] 3 Types and dimensions
3.1 The type and dimensions of D32mm shall be in accordance with the specifications of JB/200E.34.1. 3.2 The type and dimensions of DN40-50mm shall be in accordance with the provisions of Figure 1 and Table 1, 3.3 The type and dimensions of DN65-100mm shall be in accordance with the provisions of Figure 2 and Table 1. M1
1-Flange type one-way valve core: 2-Valve body, 3-Flange after force attachment
Approved by the National Machinery Industry Bureau on 1599-06-28
Implementation on 2000-01-01
JB:T 20O1.35.2
JB/T 2001.35.3
JT 2GO1.35.4
JE2o1.35.5
4Technical requirements
1:4 x 14
40×18
J8/2001.35-1999
One flange type single flash core: 2—idle body, 3—internal secretion*Figure 2
4.1 Nominal pressure 20MPa, test force 30MPa16s :
Installation details
4.2 The valve body and the core are pressure tested together to check the limit of the valve and the performance of the seal. The test method is in accordance with the technical requirements of J/T200t.33. 5 Marking examplebzxz.net
One-way valve with a nominal diameter of 40mm:
One-way DN40B/T200135—1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 50201-1994 Flood Control Standard
- JJG 226-2001 Verification Regulation of Bimetallic Thermometers
- GB/T 13393-2008 Guide to acceptance sampling inspection
- JB/T 7023-2002 Technical requirements for mirror plate forgings of hydro-generators
- JB/T 8031.2-1999 Square tool setting blocks for machine tool fixture parts and components
- GB/T 8054-2008 Single sampling procedures and tables for Inspection having desired operating Characteristics by variables
- GB/T 22274.1-2008 Guidance for GLP monitoring authorities - Part 1: Guides for compliance monitoring procedures for good laboratory practice
- NY/T 1302-2007 Rules for the Trial Technology of Cotton Varieties
- MT/T 779-1998 Retractable winch
- GB/T 14490-1993 Determination of gelatinization properties of cereals and starches - Viscometer method
- GB/T 3715-1996 Terminology related to coal quality and coal analysis
- HG/T 2839-1997 Water treatment agent disodium hydroxyethylidene diphosphonate
- CB/T 3842-2000 Rapid opening and closing watertight hatch covers
- GB/Z 19027-2005 Guidance on statistical techniques for GB/T 19001-2000
- JB/T 9890-1999 Accuracy test of multi-station movable worktable of modular machine tool
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]