GB/T 2836-1998 Ceramic pipe water pressure test method
time:
2024-08-11 14:24:16
- GB/T 2836-1998
- in force
Standard ID:
GB/T 2836-1998
Standard Name:
Ceramic pipe water pressure test method
Chinese Name:
陶管水压试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1998-10-12 -
Date of Implementation:
1999-04-01
Standard ICS number:
Glass and ceramics industry>>Ceramics>>81.060.99 Other products related to ceramicsChina Standard Classification Number:
Building Materials>>Ceramics, Glass>>Q31 Building Sanitary Ceramics
alternative situation:
GB/T 2836-1981Procurement status:
≈BS 65-1991 ≈ASTM C301-1991
publishing house:
China Standards PressISBN:
155066.1-15578Publication date:
1999-04-01
Release date:
1981-12-31Review date:
2004-10-14Drafter:
Li Dongsheng, Wang Xian, Ma Yan, Lu FenghuaDrafting Organization:
State Building Materials Industry Bureau Shandong Industrial Ceramics Research and Design InstituteFocal point Organization:
National Technical Committee for Standardization of Industrial CeramicsProposing Organization:
State Bureau of Building Materials IndustryPublishing Department:
State Administration of Quality and Technical SupervisionCompetent Authority:
China Building Materials Industry Association

Skip to download
Summary:
This standard specifies the specimen, test equipment, test steps and test report for the hydrostatic test of ceramic pipes. This standard is applicable to the test of the anti-permeability of ceramic pipes under a certain water pressure. GB/T 2836-1998 Hydrostatic test method for ceramic pipes GB/T2836-1998 Standard download decompression password: www.bzxz.net

Some standard content:
GB/T2836—1998
This standard is revised on the basis of the original GB/T2836-1981 with reference to Appendix D “Hydrostatic Test” of British Standard BS65-1991 “Sintered Ceramic Pipes, Fittings and Joints” and Chapter 7 “Hydrostatic Test” of American Standard ASTMC301-1991 “Standard Test Methods for Sintered Ceramic Pipes”. This revision only modifies the standard format and text. This standard replaces GB/T2836—1981 from the date of its release and implementation. This standard is proposed by the State Administration of Building Materials Industry. This standard is under the jurisdiction of the National Technical Committee for Standardization of Industrial Ceramics. This standard is drafted by Shandong Industrial Ceramics Research and Design Institute of the State Administration of Building Materials Industry. The main drafters of this standard are: Li Dongsheng, Wang Xian, Ma Yan, and Lu Fenghua. This standard is entrusted to Shandong Industrial Ceramics Research and Design Institute of the State Administration of Building Materials Industry for interpretation. This standard was first released in 1981.
1 Scope
National Standard of the People's Republic of China
Test method for hydrostatic proof of vitrified clay pipe
Test method for hydrostatic proof of vitrified clay pipe This standard specifies the specimen, test device, test steps and test report for hydrostatic test of vitrified clay pipe. This standard applies to the test of the anti-permeability of vitrified clay pipe under a certain water pressure. 2 Definitions
This standard adopts the following definitions.
Anti-permeability refers to the ability of vitrified clay pipe to withstand a certain internal hydrostatic pressure without leakage of the pipe wall. 3 Specimen
GB/T 2836—1998bZxz.net
Replaces GB/T2836—1981
The specimen is a whole vitrified clay pipe. The end face or the bottom surface of the socket of the specimen should be flat and free of sticky scars or cracks to facilitate sealing. 4 Test device
4.1 The test device is shown in Figure 1. The device should ensure the sealing of the ceramic tube end face and facilitate the filling of the ceramic tube with clean water. Note: Other types of devices that can meet the above requirements can also be used for this test. 1-Water inlet valve: 2-Connect to the test pressure pump 3-Air outlet valve: 4-Pressure gauge: 5, 8-Rubber sealing ring, 6, 9-End cover plate, 7-Ceramic tube sample Figure 1 Test device diagram
4.2 An automatic or manual test pressure pump can be used to apply hydrostatic pressure to the inside of the ceramic tube, or other A device that can maintain a certain hydrostatic pressure can be used to achieve the purpose of applying pressure to the inside of the ceramic tube.
4.3 Use a pressure gauge to measure the hydrostatic pressure inside the ceramic tube. The pressure gauge has an accuracy of at least Class 1. 5 Test steps
5.1 Seal both ends of the ceramic tube properly. Inject clean water into the tube until the inside of the tube is full, and close the air outlet valve and water inlet valve. Approved by the State Administration of Quality and Technical Supervision on October 12, 199816
Implementation on April 1, 1999
GB/T 2836—1998
5.2 Use a pressure test pump to gradually apply hydrostatic pressure to the inside of the ceramic tube. The pressure growth rate should be controlled to reach the test pressure value specified in the product standard after 30s.
Note: Regardless of the device used, the highest point in the tube should reach the specified pressure value. 5.3 Maintain the specified pressure for 5 minutes. If the ceramic tube does not break or leak on the surface, it is qualified. 6
Test report
The test report should include the following contents:
a) Sample name and number:
b) Standard number;
c) Sample nominal size and sample quantity;
d) Hydrostatic pressure value, pressure maintenance time, and test observation results for each sample during the test; e) Test period and test personnel.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is revised on the basis of the original GB/T2836-1981 with reference to Appendix D “Hydrostatic Test” of British Standard BS65-1991 “Sintered Ceramic Pipes, Fittings and Joints” and Chapter 7 “Hydrostatic Test” of American Standard ASTMC301-1991 “Standard Test Methods for Sintered Ceramic Pipes”. This revision only modifies the standard format and text. This standard replaces GB/T2836—1981 from the date of its release and implementation. This standard is proposed by the State Administration of Building Materials Industry. This standard is under the jurisdiction of the National Technical Committee for Standardization of Industrial Ceramics. This standard is drafted by Shandong Industrial Ceramics Research and Design Institute of the State Administration of Building Materials Industry. The main drafters of this standard are: Li Dongsheng, Wang Xian, Ma Yan, and Lu Fenghua. This standard is entrusted to Shandong Industrial Ceramics Research and Design Institute of the State Administration of Building Materials Industry for interpretation. This standard was first released in 1981.
1 Scope
National Standard of the People's Republic of China
Test method for hydrostatic proof of vitrified clay pipe
Test method for hydrostatic proof of vitrified clay pipe This standard specifies the specimen, test device, test steps and test report for hydrostatic test of vitrified clay pipe. This standard applies to the test of the anti-permeability of vitrified clay pipe under a certain water pressure. 2 Definitions
This standard adopts the following definitions.
Anti-permeability refers to the ability of vitrified clay pipe to withstand a certain internal hydrostatic pressure without leakage of the pipe wall. 3 Specimen
GB/T 2836—1998bZxz.net
Replaces GB/T2836—1981
The specimen is a whole vitrified clay pipe. The end face or the bottom surface of the socket of the specimen should be flat and free of sticky scars or cracks to facilitate sealing. 4 Test device
4.1 The test device is shown in Figure 1. The device should ensure the sealing of the ceramic tube end face and facilitate the filling of the ceramic tube with clean water. Note: Other types of devices that can meet the above requirements can also be used for this test. 1-Water inlet valve: 2-Connect to the test pressure pump 3-Air outlet valve: 4-Pressure gauge: 5, 8-Rubber sealing ring, 6, 9-End cover plate, 7-Ceramic tube sample Figure 1 Test device diagram
4.2 An automatic or manual test pressure pump can be used to apply hydrostatic pressure to the inside of the ceramic tube, or other A device that can maintain a certain hydrostatic pressure can be used to achieve the purpose of applying pressure to the inside of the ceramic tube.
4.3 Use a pressure gauge to measure the hydrostatic pressure inside the ceramic tube. The pressure gauge has an accuracy of at least Class 1. 5 Test steps
5.1 Seal both ends of the ceramic tube properly. Inject clean water into the tube until the inside of the tube is full, and close the air outlet valve and water inlet valve. Approved by the State Administration of Quality and Technical Supervision on October 12, 199816
Implementation on April 1, 1999
GB/T 2836—1998
5.2 Use a pressure test pump to gradually apply hydrostatic pressure to the inside of the ceramic tube. The pressure growth rate should be controlled to reach the test pressure value specified in the product standard after 30s.
Note: Regardless of the device used, the highest point in the tube should reach the specified pressure value. 5.3 Maintain the specified pressure for 5 minutes. If the ceramic tube does not break or leak on the surface, it is qualified. 6
Test report
The test report should include the following contents:
a) Sample name and number:
b) Standard number;
c) Sample nominal size and sample quantity;
d) Hydrostatic pressure value, pressure maintenance time, and test observation results for each sample during the test; e) Test period and test personnel.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY/T 5275-2002 Eccentric water distribution tools
- JB/T 56036-1999 Polyvinyl chloride fiberglass hose product quality classification
- GB/T 40054-2021 Societal security—Emergency management—Guidelines for public warning
- GB/T 20480-2006 Grade of sand dust storm weather
- GB/T 2922-1982 Determination of specific surface area of chromatographic carriers for chemical reagents
- GB/T 15305.1-1994 Coated abrasives - Dimensions and tolerances of sheet-shaped abrasive cloth and sandpaper
- JG/T 128-2000 Polyvinyl chloride (PVC) door and window supports
- GB/T 14926.10-2001 Methods for detecting pathogens in experimental animals
- JB/T 7925.1-1995 Sliding bearings Single-layer bearing anti-friction alloy hardness test method
- GB 8959-1988 Technical specification for dust prevention in casting
- NY/T 597-2002 High Starch Corn
- HG/T 20537.4-1992 Technical requirements for large diameter austenitic stainless steel welded steel pipes for chemical plants
- JB/T 6171-1992 Multilayer Metal Bellows Expansion Joint
- GB/T 8151.4-2000 Chemical analysis methods for zinc concentrates - Determination of silicon dioxide content
- GB/T 3871.12-1993 Test methods for agricultural wheeled and tracked tractors Part 12: Operational tests
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]