JB/T 2001.19-1999 Types and dimensions of air release valves for water systems (PN ≤ 50MPa)
time:
2024-08-14 15:20:43
- JB/T 2001.19-1999
- in force
Standard ID:
JB/T 2001.19-1999
Standard Name:
Types and dimensions of air release valves for water systems (PN ≤ 50MPa)
Chinese Name:
水系统 放气阀 型式与尺寸(PN≤50MPa)
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-06-28 -
Date of Implementation:
2000-01-01
Standard ICS number:
Fluid systems and general parts >> 23.100 Fluid power systemsChina Standard Classification Number:
Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices
alternative situation:
JB 2019-1984
Focal point Organization:
Metallurgical Equipment Standardization Technical CommitteePublishing Department:
Metallurgical Equipment Standardization Technical Committee
Skip to download
Summary:
JB/T 2001.19-1999 This standard is a revision of JB 2019-84 "Type and size of air release valve for hydraulic press (Pg≤315×100000Pa)". This standard specifies the type and size of air release valves. This standard is applicable to air release valves with a nominal pressure not exceeding 50MPa used in various pipelines that need to be released separately. This standard was first published on January 1, 1984. JB/T 2001.19-1999 Type and size of air release valve for water system (PN≤50MPa) JB/T2001.19-1999 standard download decompression password: www.bzxz.net
Some standard content:
IC.s$ 23.110
Machinery Industry Standard of the People's Republic of ChinawwW.bzxz.Net
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
1 Scope
Machinery Industry Standard of the People's Republic of China
Water system
Air release valve
Type and size
Watersygtem--Alr-escape-Typeand size(PN$50 MPa ]
To determine the type and size of the gas. JB/72001.19--1m
This standard is applicable to various valves and pipelines that need to be vented separately. The nominal pressure is not more than 50M. : 2 Types and sizes
2.1 Types should be equal to the following:. Figure 2, Figure 1: Type 1 is used in places without effective gas (see Figure 1) Type 1 is used in places with effective gas and large valve bodies (see Figure 2) The former is used for sound manufacturing (see Figure 3)
[First battle gas network Type 1: 2 seats||tt| |[One valve: 2-key thread: 3-sleeve
Home appliance industry kitchen 1999-06-28 approved
[Venting period type: 2: one period
3000-01-01 implementation
JB/T2001.19-1999
2 The dimensions should comply with the provisions of Figure 1, Figure 2, Figure 3 and Table 1. Table
Marking example
Type 1 venting valve for small-effect gas position: venting valve [carried out JR/T2001.191999
B1 2004.19.1
拍/T 2091.192
JH/r21.19.3
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of ChinawwW.bzxz.Net
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
1 Scope
Machinery Industry Standard of the People's Republic of China
Water system
Air release valve
Type and size
Watersygtem--Alr-escape-Typeand size(PN$50 MPa ]
To determine the type and size of the gas. JB/72001.19--1m
This standard is applicable to various valves and pipelines that need to be vented separately. The nominal pressure is not more than 50M. : 2 Types and sizes
2.1 Types should be equal to the following:. Figure 2, Figure 1: Type 1 is used in places without effective gas (see Figure 1) Type 1 is used in places with effective gas and large valve bodies (see Figure 2) The former is used for sound manufacturing (see Figure 3)
[First battle gas network Type 1: 2 seats||tt| |[One valve: 2-key thread: 3-sleeve
Home appliance industry kitchen 1999-06-28 approved
[Venting period type: 2: one period
3000-01-01 implementation
JB/T2001.19-1999
2 The dimensions should comply with the provisions of Figure 1, Figure 2, Figure 3 and Table 1. Table
Marking example
Type 1 venting valve for small-effect gas position: venting valve [carried out JR/T2001.191999
B1 2004.19.1
拍/T 2091.192
JH/r21.19.3
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2212.17-1996 Construction tools (brick and mortar) Single-edged masonry knives
- JB/T 56015-2002 Reliability index and test method of electromagnetic intermediate relay
- DL/T 958-2005 Terminology of fuel for power plant
- GB 8943.1-1988 Determination of copper content in pulp, paper and paperboard
- QB 1386-1991 Canned Apricot Jam
- GB/T 14765-1993 Cross handle socket wrench
- SJ 2534.7-1986 Test procedures for antennas-On-site measurements of amplitude pattens
- HG/T 3599-1999 Sulfur yellow brown 4GR (Sulfur yellow brown 6G150%)
- GB/T 17248.4-1998 Acoustics--Noise emitted by machinery and equipment--Determination of emission sound pressure level at a workstation and at other specified position from the sound power level
- MT 222-1996 Local ventilation fans for coal mines
- JB/T 6631-1993 Spiral tube heat exchanger for mechanical seal system
- JB/T 7111-1993 High voltage shunt capacitor device
- GB/T 38475-2020 Detection of mycotoxins in pigment—Rapid quantitative method of colloidal gold strip test
- GB 18279-2000 医疗器械 环氧乙烷灭菌确认和常规控制
- JB/T 8020.1-1999 Thin stoppers for machine tool fixture parts and components
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com