
QB/T 2334-1997 Qualitative determination of ultraviolet absorbers in cosmetics - UV spectrophotometer method
time:
2024-08-07 21:46:02
- QB/T 2334-1997
- in force
Standard ID:
QB/T 2334-1997
Standard Name:
Qualitative determination of ultraviolet absorbers in cosmetics - UV spectrophotometer method
Chinese Name:
化妆品中紫外线吸收剂定性测定紫外分光光度计法
Standard category:
Light Industry Standard (QB)
-
Date of Release:
1997-12-04 -
Date of Implementation:
1998-08-01
China Standard Classification Number:
Light Industry, Cultural and Living Supplies>>Daily Chemicals>>Y42 Cosmetics
Drafter:
Fei Jie, Lin YanDrafting Organization:
Shanghai Daily Chemical Industry Research InstituteFocal point Organization:
National Cosmetics Standardization CenterProposing Organization:
Quality Standards Department of China Light Industry FederationPublishing Department:
China Light Industry Federation

Skip to download
Summary:
This standard specifies the qualitative determination method of ultraviolet absorbers in cosmetics. This standard is applicable to the qualitative determination of ultraviolet absorbers in cosmetics. This standard is not applicable to the qualitative determination of non-ultraviolet absorbers in cosmetics. The minimum detection concentration of this method is 1.5 × 10ˉ6 QB/T 2334-1997 Qualitative determination of ultraviolet absorbers in cosmetics by ultraviolet spectrophotometer QB/T2334-1997 Standard download decompression password: www.bzxz.net

Some standard content:
QB/T 2334--1997
The ultraviolet rays in sunlight are electromagnetic waves of 200~~400nm, of which the ultraviolet rays in the UVB zone of 280~320nm and the ultraviolet rays in the UVA zone of 320~~400nm can make the skin sunburned, tanned, and sunburned. Adding a certain amount of sunscreen to cosmetics can prevent and reduce the damage of ultraviolet rays to the human body. At present, the sunscreens used in cosmetics include ultraviolet absorbers and ultraviolet shielding agents. The former has a strong absorption performance for ultraviolet rays in the UVA zone and UVB zone, and can reduce or completely absorb ultraviolet rays. This test method is formulated based on the principle that ultraviolet rays can be absorbed at 280~400nm, and is only applicable to the qualitative determination of ultraviolet absorbers in cosmetics. This standard is proposed by the Quality Standards Department of the China Light Industry Federation. This standard is under the jurisdiction of the National Cosmetics Standardization Center. The drafting unit of this standard: Shanghai Daily Chemical Industry Research Institute. The main drafters of this standard: Fei Jie and Lin Jiao. 100
Light Industry Standard of the People's Republic of China
Qualitative determination of ultraviolet absorbers in cosmetics by ultraviolet spectrophotometer
This standard specifies the qualitative determination method of ultraviolet absorbers in cosmetics. This standard is applicable to the qualitative determination of ultraviolet absorbers in cosmetics. This standard is not applicable to the qualitative determination of non-ultraviolet absorbers in cosmetics. The minimum detection concentration of this method is 1.5×10~6. 2 Method requirements
The sample is directly dissolved in a solvent and measured by an ultraviolet spectrophotometer. 3 Reagents
95% ethanol (GB/T679), analytical grade. 4 Instruments
4.1 Balance: graduation value 0.1g.
4.2 Ultraviolet spectrophotometer: with scanning, resolution 0.1nm. 4.3 Beaker: 100mL. bZxz.net
5 Analysis steps
5.1 Preparation of samples
QB/T2334—1997
Weigh 0.1g of sample into a 100mL beaker, add 100mL of 95% ethanol to dissolve, stir, let stand for a while, and take the clear liquid as the sample to be tested. Select the dilution multiple according to the content of sunscreen in the sample. 5.2 Determination steps
Before determination, stabilize the instrument for 30 minutes. Adjust the wavelength of the UV spectrophotometer to 280~400mm, and use 95% ethanol as blank. Pour the clear liquid of the sample to be tested into the colorimetric blood, wipe the surface of the colorimetric blood with lens paper, and scan. 6 Result indication
If the instrument has an absorption peak in this wavelength range, the sample contains ultraviolet absorber, and if there is no absorption peak, the sample does not contain ultraviolet absorber. Approved by China Light Industry General Association on December 4, 1997
KAONKAca-
Implementation on August 1, 1998
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
The ultraviolet rays in sunlight are electromagnetic waves of 200~~400nm, of which the ultraviolet rays in the UVB zone of 280~320nm and the ultraviolet rays in the UVA zone of 320~~400nm can make the skin sunburned, tanned, and sunburned. Adding a certain amount of sunscreen to cosmetics can prevent and reduce the damage of ultraviolet rays to the human body. At present, the sunscreens used in cosmetics include ultraviolet absorbers and ultraviolet shielding agents. The former has a strong absorption performance for ultraviolet rays in the UVA zone and UVB zone, and can reduce or completely absorb ultraviolet rays. This test method is formulated based on the principle that ultraviolet rays can be absorbed at 280~400nm, and is only applicable to the qualitative determination of ultraviolet absorbers in cosmetics. This standard is proposed by the Quality Standards Department of the China Light Industry Federation. This standard is under the jurisdiction of the National Cosmetics Standardization Center. The drafting unit of this standard: Shanghai Daily Chemical Industry Research Institute. The main drafters of this standard: Fei Jie and Lin Jiao. 100
Light Industry Standard of the People's Republic of China
Qualitative determination of ultraviolet absorbers in cosmetics by ultraviolet spectrophotometer
This standard specifies the qualitative determination method of ultraviolet absorbers in cosmetics. This standard is applicable to the qualitative determination of ultraviolet absorbers in cosmetics. This standard is not applicable to the qualitative determination of non-ultraviolet absorbers in cosmetics. The minimum detection concentration of this method is 1.5×10~6. 2 Method requirements
The sample is directly dissolved in a solvent and measured by an ultraviolet spectrophotometer. 3 Reagents
95% ethanol (GB/T679), analytical grade. 4 Instruments
4.1 Balance: graduation value 0.1g.
4.2 Ultraviolet spectrophotometer: with scanning, resolution 0.1nm. 4.3 Beaker: 100mL. bZxz.net
5 Analysis steps
5.1 Preparation of samples
QB/T2334—1997
Weigh 0.1g of sample into a 100mL beaker, add 100mL of 95% ethanol to dissolve, stir, let stand for a while, and take the clear liquid as the sample to be tested. Select the dilution multiple according to the content of sunscreen in the sample. 5.2 Determination steps
Before determination, stabilize the instrument for 30 minutes. Adjust the wavelength of the UV spectrophotometer to 280~400mm, and use 95% ethanol as blank. Pour the clear liquid of the sample to be tested into the colorimetric blood, wipe the surface of the colorimetric blood with lens paper, and scan. 6 Result indication
If the instrument has an absorption peak in this wavelength range, the sample contains ultraviolet absorber, and if there is no absorption peak, the sample does not contain ultraviolet absorber. Approved by China Light Industry General Association on December 4, 1997
KAONKAca-
Implementation on August 1, 1998
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 9160.1-1999 Dimensions of the feed rod for single-spindle turret automatic lathe
- JB/T 8874-2000 Technical requirements for rolling bearing seats
- YC/T 37.1-2002 Determination of physical properties of filter rods Part 1: Length electro-optical method
- GB/T 18978.11-2004 Ergonomic requirements for office work with visual display terminals (VDTs)-Part 11:Guidance on usa
- JB/T 6173-1992 Water-soluble organic flux
- GB/T 5413.5-1997 Determination of lactose, sucrose and total sugars in infant formula and milk powder
- JB/T 8464-1996 Progressive distributor 16MPa
- GB/T 15187-1994 Method for determining the performance of wet dust collectors
- GB/T 5526-1985 Vegetable oils and fats - Determination of specific gravity
- HG/T 2584-2002 Rubber Industrial Gloves
- QB/T 2466-1999 Tinned (chrome) thin steel plate round full-open easy-open lid
- QX/T 19-2003 Net total radiation meter
- SJ/T 10556-1994 Exterior collidal graphite for black and white picture tubes
- SY/T 5374-2000 Methods of using pre-cementing fluid for oil and gas wells
- GB/T 35636-2017 Specification for surveying and mapping of urban underground space
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com