
CB 739-68 Portable Battery Light
time:
2024-09-20 16:05:12
- CB 739-68
- in force
Standard ID:
CB 739-68
Standard Name:
Portable Battery Light
Chinese Name:
手提蓄电池灯
Standard category:
Ship Industry Standard (CB)
China Standard Classification Number:
Ships>>Ship electrical, observation and navigation equipment>>U63 Bed lighting and other electrical appliances

Skip to download
Summary:
CB 739-68 Portable Battery Light CB739-68 Standard Download Decompression Password: www.bzxz.net

Some standard content:
The Sixth Machinery Industry Department of the People's Republic of China
Portable Battery Lamp
This standard is applicable to portable battery lamps for local lighting (hereinafter referred to as portable lamps). 1. Types, basic parameters and dimensions
The types, basic parameters and dimensions of portable lamps are as follows: 12
Structural form
People's brand small special bulbs
Note: The model of this lantern has been specified in CB349--64. Stream
Lamp holder type
2. Technical requirements
Portable lamps should meet the requirements of this standard and be manufactured according to the unified drawings. Portable lamps should be able to work normally when the ambient temperature is -25~+45℃. CB739-68
Glass color
Colorless frosted
The switch and the conductive part of the elastic contact of the portable lamp should maintain good contact. The insulation resistance between the conductive parts of the portable lamp and the outer shell shall not be less than 100MQ when the ambient temperature is 20±5℃ and the relative humidity is 80±5%, and shall not be less than 3MQ when the ambient temperature is 40±5℃ and the relative humidity is 95±3%. The light transmittance of the protective glass shall not be less than 80%. 6.
After the portable lamp is loaded with the test battery and correctly focused, it shall ensure that the illumination within the circle with a diameter of 0.5m7.
around the optical axis on a plane 1m away from the lamp (with colorless frosted glass) is not less than 6 lux. 8.
The portable lamp shall be supplied with 2GN-8-1 type batteries that meet the requirements. The metal parts of the portable lamp shall have a corrosion-resistant protective layer. Issued by the Sixth Ministry of Machinery Industry
Implemented on October 1, 1968
Total 2 pages Page 2Www.bzxZ.net
CB739-68
10. The same parts and batteries of portable lamps should be interchangeable. 11. The housing of portable lamps should be marked with luminous powder (this requirement only applies to special orders). 12. Under the condition of correct use and regular charging and maintenance, the warranty period is one and a half years from the date of delivery. III. Acceptance rules and test methods
13. Before each portable lamp leaves the factory, it should be inspected by the technical inspection department of the manufacturer and should be accompanied by a factory certificate. 14. During acceptance, in addition to the appearance and complete set inspection of each unit, 3% but not less than 3 units shall be selected from each batch of delivered products for random inspection according to Articles 4, 5 (normal insulation resistance) and 7. 15. After the structural material or process specification is changed, and these changes may affect the performance of the portable lamp, and when the batch production exceeds one year, the type test should be carried out. In addition to the acceptance items, the test items also need to be tested and inspected according to Articles 2, 3, 6, 9 and 10. The number of tests is 3 sets.
16. During the sampling acceptance, if there are unqualified ones, double sampling should be carried out for re-inspection. If unqualified ones are still found during the re-inspection, the acceptance should be stopped, and the manufacturer should check the reasons and resubmit for acceptance after eliminating the defects. 17. In the test of Article 4 of this standard, the charged test battery and bulb are installed in the lamp. When the switch is in the "on" position, the bulb should light up. When the switch is in the "off" position, the bulb should go out. Repeat the operation 3 times. If there is no fault, it is qualified, otherwise it is unqualified.
18. Articles 3, 5, 6, and 9 of this standard shall be checked according to the test methods of Articles 21, 22, 27, and 28 of CB339-64. 19. Article 7 of this standard uses an illuminometer to measure illumination. Randomly select 3 points within a circle with a diameter of 0.5m; if the illumination at all 3 points can meet the requirements, the test is considered qualified. If one point is unqualified, the test is considered unqualified. IV. Marking, packaging and storage
20. Marking, packaging and storage shall be carried out in accordance with Articles 32, 33, 34, and 35 of CB339-64. If the boss needs this standard in PDF format, you can provide me with an email address (provided that you have purchased this standard) and I will send it to your email address for free.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Portable Battery Lamp
This standard is applicable to portable battery lamps for local lighting (hereinafter referred to as portable lamps). 1. Types, basic parameters and dimensions
The types, basic parameters and dimensions of portable lamps are as follows: 12
Structural form
People's brand small special bulbs
Note: The model of this lantern has been specified in CB349--64. Stream
Lamp holder type
2. Technical requirements
Portable lamps should meet the requirements of this standard and be manufactured according to the unified drawings. Portable lamps should be able to work normally when the ambient temperature is -25~+45℃. CB739-68
Glass color
Colorless frosted
The switch and the conductive part of the elastic contact of the portable lamp should maintain good contact. The insulation resistance between the conductive parts of the portable lamp and the outer shell shall not be less than 100MQ when the ambient temperature is 20±5℃ and the relative humidity is 80±5%, and shall not be less than 3MQ when the ambient temperature is 40±5℃ and the relative humidity is 95±3%. The light transmittance of the protective glass shall not be less than 80%. 6.
After the portable lamp is loaded with the test battery and correctly focused, it shall ensure that the illumination within the circle with a diameter of 0.5m7.
around the optical axis on a plane 1m away from the lamp (with colorless frosted glass) is not less than 6 lux. 8.
The portable lamp shall be supplied with 2GN-8-1 type batteries that meet the requirements. The metal parts of the portable lamp shall have a corrosion-resistant protective layer. Issued by the Sixth Ministry of Machinery Industry
Implemented on October 1, 1968
Total 2 pages Page 2Www.bzxZ.net
CB739-68
10. The same parts and batteries of portable lamps should be interchangeable. 11. The housing of portable lamps should be marked with luminous powder (this requirement only applies to special orders). 12. Under the condition of correct use and regular charging and maintenance, the warranty period is one and a half years from the date of delivery. III. Acceptance rules and test methods
13. Before each portable lamp leaves the factory, it should be inspected by the technical inspection department of the manufacturer and should be accompanied by a factory certificate. 14. During acceptance, in addition to the appearance and complete set inspection of each unit, 3% but not less than 3 units shall be selected from each batch of delivered products for random inspection according to Articles 4, 5 (normal insulation resistance) and 7. 15. After the structural material or process specification is changed, and these changes may affect the performance of the portable lamp, and when the batch production exceeds one year, the type test should be carried out. In addition to the acceptance items, the test items also need to be tested and inspected according to Articles 2, 3, 6, 9 and 10. The number of tests is 3 sets.
16. During the sampling acceptance, if there are unqualified ones, double sampling should be carried out for re-inspection. If unqualified ones are still found during the re-inspection, the acceptance should be stopped, and the manufacturer should check the reasons and resubmit for acceptance after eliminating the defects. 17. In the test of Article 4 of this standard, the charged test battery and bulb are installed in the lamp. When the switch is in the "on" position, the bulb should light up. When the switch is in the "off" position, the bulb should go out. Repeat the operation 3 times. If there is no fault, it is qualified, otherwise it is unqualified.
18. Articles 3, 5, 6, and 9 of this standard shall be checked according to the test methods of Articles 21, 22, 27, and 28 of CB339-64. 19. Article 7 of this standard uses an illuminometer to measure illumination. Randomly select 3 points within a circle with a diameter of 0.5m; if the illumination at all 3 points can meet the requirements, the test is considered qualified. If one point is unqualified, the test is considered unqualified. IV. Marking, packaging and storage
20. Marking, packaging and storage shall be carried out in accordance with Articles 32, 33, 34, and 35 of CB339-64. If the boss needs this standard in PDF format, you can provide me with an email address (provided that you have purchased this standard) and I will send it to your email address for free.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- BB/T 0044-2007 Packing containers-Plastic bottle for packing of pesticides
- JG/T 3060-1999 Composite steel formwork
- CB/T 3726-1995 Air duct damper
- SY/T 5587.3-1993 Procedure for well killing and blowdown in conventional well repair work for oil and water wells
- NY/T 1519-2007 Green coffee-Defect reference chart
- GB/T 14257-2009 Bar code for commodity - Bar code symbol placement guidelines
- GB 17268-1998 Industrial non-refillable welded steel cylinders
- GB/T 17695-1999 Public information graphical symbols for use in the map--Common symbols
- JB/T 6329-2002 Marine low voltage fuses
- GB/T 3921.2-1997 Textiles - Tests for colour fastness - Colour fastness to washing: Test 2
- JB/T 7978-1999 Steel ruler and rock ruler
- JB/T 9005.5-1999 Casting pulley for crane, type B
- GB 18428-2001 Glass balls for automatic fire extinguishing systems
- SY/T 0450-1997 Specification for seismic design of buried steel pipelines for oil (gas) transportation
- RB/T 151-2016 Guidelines for the estimation of measurement uncertainty of food microbiological quantitative detection
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]