JB/T 5971-1992 Single-stage multi-vane vacuum pump
time:
2024-06-28 09:00:34
- JB/T 5971-1992
- in force
Standard ID:
JB/T 5971-1992
Standard Name:
Single-stage multi-vane vacuum pump
Chinese Name:
单级多旋片式真空泵
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-07-20 -
Date of Implementation:
1993-01-01
China Standard Classification Number:
Machinery>>General Machinery and Equipment>>J78 Vacuum Technology and Equipment
Focal point Organization:
National Vacuum Technology Standardization Technical CommitteePublishing Department:
National Vacuum Technology Standardization Technical Committee

Skip to download
Summary:
This standard specifies the type and basic parameters, technical requirements, test methods, inspection rules and marking, packaging, storage, etc. of single-stage multi-vane vacuum pumps. This standard applies to single-stage multi-vane vacuum pumps. This standard does not apply to single-stage oil-sealed rotary vane vacuum pumps. JB/T 5971-1992 Single-stage multi-vane vacuum pumps JB/T5971-1992 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T5971-92
Single-stage multi-rotary vane vacuum pump
Published on July 20, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Single-stage multi-rotary vane vacuum pump
1 Subject content and scope of application
JB/T5971-92
This standard specifies the type and basic parameters, technical requirements, test methods, inspection rules and marking, packaging, storage, etc. of single-stage multi-rotary vane vacuum pumps.
This standard applies to single-stage multi-rotary vane vacuum pumps (hereinafter referred to as pumps), and does not apply to single-stage oil-sealed rotary vane vacuum pumps. Reference standards
GB3163
GB6306
GB7772
GB/T13306wwW.bzxz.Net
GB/T13384
ZBJ78016
3 Terminology
Terms of vacuum technology
Performance test method of positive displacement vacuum pump
Noise measurement method of positive displacement vacuum pump
General technical conditions for packaging of electromechanical products
Vacuum pump model compilation method
The terms used in this standard shall comply with the provisions of GB3163. Type and basic parameters
The pump is a single-stage multi-vane type.
4.2 Model
According to the provisions of ZBJ78016.
4.3 Basic parameters
Basic parameters shall comply with the following table,
XD-100
XD-160
XD-250
Geometric pumping speed
Approved by the Ministry of Machinery and Electronics Industry on July 20, 1992 Limiting pressure
<2×102
Noise sound power level
Power consumption
Inlet inner diameter
Implemented on January 1, 1993
5 Technical requirements
JB/T597192
5.1 The pump shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 5.2 The paint on the outside of the pump shall be smooth.
5.3 The ambient operating temperature of the pump is 5~40℃. 5.4 The ultimate pressure of the pump shall comply with the provisions of Table 1; the ultimate pressure is the pressure measured at the specified position on the test cover with an oil U-tube vacuum gauge. The pumping rate shall meet the requirements of Article 5.5 of this standard. 5.5 The pumping rate of the pump, measured at an inlet pressure of 7×10\Pa, shall not be less than 80% of its geometric pumping speed. 5.6 During normal operation, the maximum power consumption of the pump shall not exceed the power of the matching motor (except for instantaneous overload). When the pump is connected to the atmosphere at the air inlet, oil shall not be sprayed within 2 minutes: 5.7
When the pump is running at the ultimate pressure, its noise shall comply with the provisions of Table 1. 5.8
5.9 After parking, the restart shall not be hindered by oil return. The pump should not leak oil, and the water-cooled pump should not leak water. 5.10
The complete set of products should give detailed provisions for auxiliary machines, accessories and spare parts in the product manual. 5.11
On the premise that the user complies with the storage, use and installation rules of the pump, within one year from the date of shipment from the manufacturer, if the product is damaged or cannot operate normally due to poor manufacturing quality, the manufacturer shall be responsible for free repair or replacement for the user. Test methods and inspection rules
The test method of the pump shall be carried out in accordance with GB6306 and GB7772. 6.2 Each pump product must be inspected and qualified by the inspection department before it can leave the factory. 6.3 Pump product inspection is divided into factory inspection and type inspection: 6.3.1
Factory inspection items include:
Ultimate pressure;
Operation test for 2h.
Type inspection: Whenever a new product is developed or there is a major change in the design, process or material of the product, a type inspection shall be carried out. The items include: 6.3.2
Ultimate pressure;
Pumping speed;
Power consumption;
Noise;
Oil injection,
Type inspection 5% of each batch shall be sampled, but not less than two units. If it fails, double sampling shall be carried out. If it fails again, the batch of products shall be inspected one by one. Marking, packaging, storage
Each pump shall be nailed with a product nameplate in a conspicuous position. The type and size of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall indicate the manufacturer's name;
Product model, name and number;
Product technical specifications;
Ultimate pressure, Pa; Pumping speed, m/h; Motor power, kW; Speed, min-; d. Year and month of manufacture.
7.2 Pumps are not allowed to be stored outdoors to avoid rust and damage. 7.3 Each pump should be accompanied by the following documents when it leaves the factory: a. Product certificate;
b. Packing list;
c. Product manual.
7.4 Packaging
Pump packaging should comply with the provisions of GB/T13384.
Additional instructions:
JB/T5971-92
This standard is proposed and managed by the National Vacuum Technology Standardization Technical Committee. This standard was drafted by the Shenyang Vacuum Technology Research Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Zhang Shufan, Li Chunying and Zhang Chenlian. People's Republic of China
Mechanical Industry Standard
Single-stage multi-vane vacuum pump
JB/T 597192
Published by the Mechanical Standardization Research Institute of the Ministry of Machinery and Electronics Industry Printed by the Mechanical Standardization Research Institute of the Ministry of Machinery and Electronics Industry (PO Box 8144, Beijing 100081)
Copyright reserved
Format 880×1230
First edition in October 1992
Print run 0.001
No reproduction allowed
Sheet 3/8
Word count 6000
First printing in October 1992
Price 1.00 yuan
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T5971-92
Single-stage multi-rotary vane vacuum pump
Published on July 20, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Single-stage multi-rotary vane vacuum pump
1 Subject content and scope of application
JB/T5971-92
This standard specifies the type and basic parameters, technical requirements, test methods, inspection rules and marking, packaging, storage, etc. of single-stage multi-rotary vane vacuum pumps.
This standard applies to single-stage multi-rotary vane vacuum pumps (hereinafter referred to as pumps), and does not apply to single-stage oil-sealed rotary vane vacuum pumps. Reference standards
GB3163
GB6306
GB7772
GB/T13306wwW.bzxz.Net
GB/T13384
ZBJ78016
3 Terminology
Terms of vacuum technology
Performance test method of positive displacement vacuum pump
Noise measurement method of positive displacement vacuum pump
General technical conditions for packaging of electromechanical products
Vacuum pump model compilation method
The terms used in this standard shall comply with the provisions of GB3163. Type and basic parameters
The pump is a single-stage multi-vane type.
4.2 Model
According to the provisions of ZBJ78016.
4.3 Basic parameters
Basic parameters shall comply with the following table,
XD-100
XD-160
XD-250
Geometric pumping speed
Approved by the Ministry of Machinery and Electronics Industry on July 20, 1992 Limiting pressure
<2×102
Noise sound power level
Power consumption
Inlet inner diameter
Implemented on January 1, 1993
5 Technical requirements
JB/T597192
5.1 The pump shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 5.2 The paint on the outside of the pump shall be smooth.
5.3 The ambient operating temperature of the pump is 5~40℃. 5.4 The ultimate pressure of the pump shall comply with the provisions of Table 1; the ultimate pressure is the pressure measured at the specified position on the test cover with an oil U-tube vacuum gauge. The pumping rate shall meet the requirements of Article 5.5 of this standard. 5.5 The pumping rate of the pump, measured at an inlet pressure of 7×10\Pa, shall not be less than 80% of its geometric pumping speed. 5.6 During normal operation, the maximum power consumption of the pump shall not exceed the power of the matching motor (except for instantaneous overload). When the pump is connected to the atmosphere at the air inlet, oil shall not be sprayed within 2 minutes: 5.7
When the pump is running at the ultimate pressure, its noise shall comply with the provisions of Table 1. 5.8
5.9 After parking, the restart shall not be hindered by oil return. The pump should not leak oil, and the water-cooled pump should not leak water. 5.10
The complete set of products should give detailed provisions for auxiliary machines, accessories and spare parts in the product manual. 5.11
On the premise that the user complies with the storage, use and installation rules of the pump, within one year from the date of shipment from the manufacturer, if the product is damaged or cannot operate normally due to poor manufacturing quality, the manufacturer shall be responsible for free repair or replacement for the user. Test methods and inspection rules
The test method of the pump shall be carried out in accordance with GB6306 and GB7772. 6.2 Each pump product must be inspected and qualified by the inspection department before it can leave the factory. 6.3 Pump product inspection is divided into factory inspection and type inspection: 6.3.1
Factory inspection items include:
Ultimate pressure;
Operation test for 2h.
Type inspection: Whenever a new product is developed or there is a major change in the design, process or material of the product, a type inspection shall be carried out. The items include: 6.3.2
Ultimate pressure;
Pumping speed;
Power consumption;
Noise;
Oil injection,
Type inspection 5% of each batch shall be sampled, but not less than two units. If it fails, double sampling shall be carried out. If it fails again, the batch of products shall be inspected one by one. Marking, packaging, storage
Each pump shall be nailed with a product nameplate in a conspicuous position. The type and size of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall indicate the manufacturer's name;
Product model, name and number;
Product technical specifications;
Ultimate pressure, Pa; Pumping speed, m/h; Motor power, kW; Speed, min-; d. Year and month of manufacture.
7.2 Pumps are not allowed to be stored outdoors to avoid rust and damage. 7.3 Each pump should be accompanied by the following documents when it leaves the factory: a. Product certificate;
b. Packing list;
c. Product manual.
7.4 Packaging
Pump packaging should comply with the provisions of GB/T13384.
Additional instructions:
JB/T5971-92
This standard is proposed and managed by the National Vacuum Technology Standardization Technical Committee. This standard was drafted by the Shenyang Vacuum Technology Research Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Zhang Shufan, Li Chunying and Zhang Chenlian. People's Republic of China
Mechanical Industry Standard
Single-stage multi-vane vacuum pump
JB/T 597192
Published by the Mechanical Standardization Research Institute of the Ministry of Machinery and Electronics Industry Printed by the Mechanical Standardization Research Institute of the Ministry of Machinery and Electronics Industry (PO Box 8144, Beijing 100081)
Copyright reserved
Format 880×1230
First edition in October 1992
Print run 0.001
No reproduction allowed
Sheet 3/8
Word count 6000
First printing in October 1992
Price 1.00 yuan
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 2893.4-2013 Graphical symbols—Safety colours and safety signs—Part 4:Colorimetric and photometric properties of safety sign materials
- HG 3027-1988 Determination of plasticizer content in organic glass UV spectrometry
- JG/T 148-2002 Steel Tube Radiator
- JB/T 6522-1992 Technical requirements for circuit breakers for narrow-gauge industrial and mining electric locomotives
- JB/T 7029-1993 Technical requirements for non-magnetic retaining ring forgings for steam turbine generators below 50MW
- GB/T 4772.2-1999 Dimensions and output power classes of rotating electrical machines Part 2: Frame sizes 355 to 1 000 and flange sizes 1 180 to 2 360
- JB/T 7279-1994 Test methods for mechanical steering systems of wheeled tractors
- GB 15166.2-1994 AC high voltage fuse current limiting fuse
- JB/T 5299-1998 Hydraulic control check butterfly valve
- GB/T 32000-2015 Guidelines for the construction of beautiful villages
- GB/T 14990-1994 Iron-cobalt-molybdenum hysteresis alloy hot-rolled (or forged) bars
- JB/T 8981-1999 Technical requirements for brushed three-phase synchronous generators (frame sizes 132-400)
- JB/T 9713-1999 Technical requirements for wet copper-based friction parts for construction machinery
- JGJ/T 191-2009 Standard for terminology of building materials
- JB/T 7544.2-1994 Technical requirements for horizontal pillow-type seam wrapping machines
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]