GB/T 5163-1985 Determination of density of permeable sintered metal materials
time:
2024-08-04 21:25:08
- GB/T 5163-1985
- Abolished
Standard ID:
GB/T 5163-1985
Standard Name:
Determination of density of permeable sintered metal materials
Chinese Name:
可渗性烧结金属材料 密度的测定
Standard category:
National Standard (GB)
-
Date of Release:
1985-05-08 -
Date of Implementation:
1986-02-01 -
Date of Expiration:
2006-11-01
Standard ICS number:
Metallurgy>>Metal Material Testing>>77.040.30 Chemical Analysis of Metal MaterialsChina Standard Classification Number:
Metallurgy>>Methods for testing physical and chemical properties of metals>>H21 Methods for testing physical properties of metals
alternative situation:
Replaced by GB/T 5163-2006Procurement status:
=ISO 2738
Review date:
2004-10-14Drafting Organization:
Central Iron and Steel Research InstituteFocal point Organization:
National Technical Committee for Standardization of Nonferrous MetalsPublishing Department:
China Nonferrous Metals Industry AssociationCompetent Authority:
China Nonferrous Metals Industry Association

Skip to download
Summary:
GB/T 5163-1985 Determination of density of permeable sintered metallic materials GB/T5163-1985 standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Permeable sintered metal materials
Determination of density
This standard specifies the method for determining the density of permeable sintered metal materials. UDC 669-492.8
GB 5163-85
This standard is equivalent to the relevant parts of ISO 2738 "Permeable sintered metal materials-Determination of density and open porosity". This standard is particularly applicable to sintered metal porous bearings and mechanical parts made of metal powder by molding and sintering. 1 Principle
After cleaning, degreasing and drying, the sample is weighed in air. Then it is waterproofed, that is, it is soaked with an appropriate liquid or covered with a surface, and weighed again in air and water. The volume of the sample can be calculated from the reduction in mass when it is weighed in water, and the density can be calculated.
2 Sample
2.1 Clean the sample surface. If the sample contains oil, remove the oil with a Soxhlet extractor, then place it in a drying oven. After the temperature reaches 110℃, keep it for 1 hour and then cool it to room temperature. 2.2 If the sample volume is less than 0.5cm2, several samples can be collected and measured together. When the sample is too large, the sample can be broken into small pieces, but the density of all small pieces must be measured. The density of the sample is calculated using the total mass and total volume. The test report should indicate whether a whole piece or a small piece of sample is used. As much as possible, use a whole piece (less than 200g) of the sample for the test. 3 Instruments and reagents
3.1 The Soxhlet extractor is represented by a figure in GB5165-85 "Permeable sintered metal materials-Determination of oil content". 3.2 Analytical balance
It should have sufficient capacity and be able to weigh the sample mass accurately to 0.01%. 3.3 The container for distilled water
must be large enough to hold the sample and the weighing device (indicated by the attached figure in GB5165-85). 3.4 The oil diffusion device
can hold the sample and heat the oil.
3.5 The temperature in the dryer-oven
can be maintained at 110±5℃. 3.6 Immersion oil and vaseline
3.7 Solvent for oil
The choice of solvent should ensure that the contained oil is completely dissolved. Usually light gasoline, ether or carbon tetrachloride is used as the solvent. Test steps
4.1 Weigh the cleanest sample.
4.2 Waterproof treatment
4.2.1 The sample can be incompletely immersed (suitable for measuring volume), and the test time can be shortened. Issued by the National Bureau of Standards on May 8, 1985
Implemented on February 1, 1986
GB 5163—85
The sample is immersed in hot oil at 65±5℃ until no bubbles appear. After cooling to room temperature, the sample is taken out of the oil, and the excess oil on the surface is wiped off with absorbent paper or cloth. Be careful not to suck out the oil in the hole. It can be weighed. 4.2.2 The surface covering method can also be used (suitable for measuring volume), that is, vaseline is coated on the surface of the sample and the excess is removed. 4.3 The sample that has been spread with oil or covered on the surface is placed in a weighing device, or hung with a fine nylon thread, and weighed first in air and then in water.
4.4 In order to remove bubbles attached to the sample, the sample can be gently shaken in water, and 2 drops of wetting agent can be added to the water. 4.5 The sample and water should be at an intermediate temperature, usually the test temperature is room temperature. 5 Calculation and expression of results
Calculation of results
Formula: d-
--sample density, g/cm3,
--mass of dry (oil-free) sample weighed in air, g; m---total mass of oil-free sample weighed in air (including the mass of fine nylon thread), g; ms--total mass of oil-immersed sample weighed in water (including the mass of fine nylon thread), g; - density of water at test temperature, g/cm3. 5.2 Expression of results
Should be accurate to 0.01g/cm2.
6 Test report
The test report should include the following points:
a. This [national standard number;
Detailed description of the test specimen required for identification;
Results obtained and test methods applied,
Detailed description of all factors that may affect the results; Other operations not specified in this national standard or optional. Additional remarks: bzxZ.net
This standard was proposed by the Ministry of Metallurgical Industry of the People's Republic of China and China Nonferrous Metals Industry Corporation. This standard was drafted by the Iron and Steel Research Institute of the Ministry of Metallurgical Industry. The main drafter of this standard was Tang Guifen.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Permeable sintered metal materials
Determination of density
This standard specifies the method for determining the density of permeable sintered metal materials. UDC 669-492.8
GB 5163-85
This standard is equivalent to the relevant parts of ISO 2738 "Permeable sintered metal materials-Determination of density and open porosity". This standard is particularly applicable to sintered metal porous bearings and mechanical parts made of metal powder by molding and sintering. 1 Principle
After cleaning, degreasing and drying, the sample is weighed in air. Then it is waterproofed, that is, it is soaked with an appropriate liquid or covered with a surface, and weighed again in air and water. The volume of the sample can be calculated from the reduction in mass when it is weighed in water, and the density can be calculated.
2 Sample
2.1 Clean the sample surface. If the sample contains oil, remove the oil with a Soxhlet extractor, then place it in a drying oven. After the temperature reaches 110℃, keep it for 1 hour and then cool it to room temperature. 2.2 If the sample volume is less than 0.5cm2, several samples can be collected and measured together. When the sample is too large, the sample can be broken into small pieces, but the density of all small pieces must be measured. The density of the sample is calculated using the total mass and total volume. The test report should indicate whether a whole piece or a small piece of sample is used. As much as possible, use a whole piece (less than 200g) of the sample for the test. 3 Instruments and reagents
3.1 The Soxhlet extractor is represented by a figure in GB5165-85 "Permeable sintered metal materials-Determination of oil content". 3.2 Analytical balance
It should have sufficient capacity and be able to weigh the sample mass accurately to 0.01%. 3.3 The container for distilled water
must be large enough to hold the sample and the weighing device (indicated by the attached figure in GB5165-85). 3.4 The oil diffusion device
can hold the sample and heat the oil.
3.5 The temperature in the dryer-oven
can be maintained at 110±5℃. 3.6 Immersion oil and vaseline
3.7 Solvent for oil
The choice of solvent should ensure that the contained oil is completely dissolved. Usually light gasoline, ether or carbon tetrachloride is used as the solvent. Test steps
4.1 Weigh the cleanest sample.
4.2 Waterproof treatment
4.2.1 The sample can be incompletely immersed (suitable for measuring volume), and the test time can be shortened. Issued by the National Bureau of Standards on May 8, 1985
Implemented on February 1, 1986
GB 5163—85
The sample is immersed in hot oil at 65±5℃ until no bubbles appear. After cooling to room temperature, the sample is taken out of the oil, and the excess oil on the surface is wiped off with absorbent paper or cloth. Be careful not to suck out the oil in the hole. It can be weighed. 4.2.2 The surface covering method can also be used (suitable for measuring volume), that is, vaseline is coated on the surface of the sample and the excess is removed. 4.3 The sample that has been spread with oil or covered on the surface is placed in a weighing device, or hung with a fine nylon thread, and weighed first in air and then in water.
4.4 In order to remove bubbles attached to the sample, the sample can be gently shaken in water, and 2 drops of wetting agent can be added to the water. 4.5 The sample and water should be at an intermediate temperature, usually the test temperature is room temperature. 5 Calculation and expression of results
Calculation of results
Formula: d-
--sample density, g/cm3,
--mass of dry (oil-free) sample weighed in air, g; m---total mass of oil-free sample weighed in air (including the mass of fine nylon thread), g; ms--total mass of oil-immersed sample weighed in water (including the mass of fine nylon thread), g; - density of water at test temperature, g/cm3. 5.2 Expression of results
Should be accurate to 0.01g/cm2.
6 Test report
The test report should include the following points:
a. This [national standard number;
Detailed description of the test specimen required for identification;
Results obtained and test methods applied,
Detailed description of all factors that may affect the results; Other operations not specified in this national standard or optional. Additional remarks: bzxZ.net
This standard was proposed by the Ministry of Metallurgical Industry of the People's Republic of China and China Nonferrous Metals Industry Corporation. This standard was drafted by the Iron and Steel Research Institute of the Ministry of Metallurgical Industry. The main drafter of this standard was Tang Guifen.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 3582-1999 Basic parameters of anvil micro-motion hydraulic die forging hammer
- NY/T 752-2003 Green Food Peak Products
- QB/T 2602-2003 Public seating for cinemas and theaters
- GB 5144-1994 Safety regulations for tower cranes
- GB/T 15913-1995 Energy-saving monitoring method for fan units and pipe network systems
- JB/T 10274-2001 General technical requirements for AC servo motors for CNC machine tools
- GB/T 8098-2003 Installation surface of flow control valves with compensation for hydraulic transmission
- JB/T 3411.15-1999 Dimensions of thread cutting chucks
- HG/T 2747-1996 Naphthol AS-OL
- GB/T 15351-1994 Chemical reagent phenol red
- HG/T 2143-1991 Glass-lined equipment nozzles
- GB 3121-1982 Nickel and nickel alloy wire for vacuum devices
- GB/T 4324.18-1984 Chemical analysis of tungsten - Atomic absorption spectrophotometric method for determination of potassium content
- GB/T 5591.1-2002 Flexible composite materials for electrical insulation Part 1: Definitions and general requirements
- GB/T 3917.2-1997 Tear properties of textile fabrics Part 2: Determination of tear strength of tongue-shaped specimens
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com