GB/T 5053.3-1985 Test methods and requirements for electrical connectors between vehicles and trailers
time:
2024-08-04 23:00:23
- GB/T 5053.3-1985
- Abolished
Standard ID:
GB/T 5053.3-1985
Standard Name:
Test methods and requirements for electrical connectors between vehicles and trailers
Chinese Name:
汽车与挂车之间电连接器的试验方法与要求
Standard category:
National Standard (GB)
-
Date of Release:
1985-03-09 -
Date of Implementation:
1986-02-01 -
Date of Expiration:
2007-08-01
Standard ICS number:
Road vehicle engineering>>Road vehicle equipment>>43.040.10 Electrical and electronic equipmentChina Standard Classification Number:
Vehicles>>Automotive Electronics, Electrical Equipment and Instruments>>T36 Electronics, Electrical Equipment
alternative situation:
Replaced by GB/T 5053.3-2006Procurement status:
=ISO 4091-78
Review date:
2004-10-14Drafting Organization:
Highway Research Institute, Ministry of TransportFocal point Organization:
National Automobile Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
National Development and Reform Commission
Skip to download
Summary:
This standard specifies the test methods and requirements for electrical connectors between vehicles and trailers. This standard applies to 12N, 12S, 24N and 24S electrical connectors for vehicles with rated voltages of 6V, 12V and 24V. This standard is equivalent to the international standard ISO 4091-1978 "Road vehicles - Electrical connectors between tractor vehicles and trailers - Test methods and requirements". GB/T 5053.3-1985 Test methods and requirements for electrical connectors between vehicles and trailers GB/T5053.3-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Test methods and requirements of electrical connections between motor yehicles and towed vehicles
This standard specifies the test methods and requirements of electrical connectors between motor yehicles and towed vehicles. UDC 629.11.013
.5: 621.315
GB 5053.3--85
This standard applies to 12N, 12S, 24N and 24S electrical connectors for vehicles with rated voltages of 6V, 12V and 24V.
This standard is equivalent to the international standard ISO4091-1978 "Road vehicles-Electrical connectors between towing vehicles and trailers-Test methods and requirements".
1 Insertion force and withdrawal force test
Ambient temperature: 23±5℃.
The plug and plug tube should be dry and clean.
The static test method (static gravity method) is used for the tenth plugging and unplugging. Insertion force: maximum 200N.
Pull-out force: maximum 200N.
Minimum 20N.
2 Current carrying capacity test
Ambient temperature: 23±5℃.
Two adjacent contacts shall not be tested at the same time. Each contact shall be able to continuously pass a direct current of 15A. During the test, the contact under test and the common circuit contact form a circuit, through which a direct current of 15A is passed for 1h. The temperature rise of the plug and plug tube near the insulator shall not exceed 20℃. In the test circuit, the length of the wire connected to the terminal is at least 1m, and the cross-sectional area is 1.5mm2. 3 Maximum allowable voltage drop test
Ambient temperature: 23±5℃.
The voltage drop between the plug and the corresponding plug shall be measured at the tenth insertion, with a current of 10A. 3.1 For electrical connectors whose cables are not die-cast into sockets and plugs, the following voltage drops shall be measured: 3.1.1 The voltage drop between each plug and the terminal of the corresponding plug shall not exceed 5mV/A. 3.1.2 The voltage drop between each terminal and the connecting wire at a distance of 10mm from the terminal shall not exceed 0.5mV/A (the cross-sectional area of the wire is 1.5mm2).
3.2 For electrical connectors whose cables are only die-cast into sockets or only die-cast into plugs, the following voltage drops shall be measured: 3.2.1 The voltage drop between each pluggable terminal and the connecting wire of the corresponding plug (or plug) at a distance of 100mm from the end face of the socket (or plug) shall not exceed 5.5mV/A (the cross-sectional area of the wire is 1.5mm2). 3.2.2 The voltage drop between each pluggable terminal and the connecting wire at 10mm from the terminal shall not exceed 0.5mV/A (the cross-sectional area of the wire is 1.5mm2).
National Bureau of Standards Issued on March 9, 1985
Implementation on February 1, 1986
GB 5053.385
3.3 For the electrical connector of the cable line, which is a die-cast socket and plug, the voltage drop of each pair of corresponding connecting wires at 100mm from the end face of the socket and plug shall not exceed 6mV/A (the cross-sectional area of the wire is 1.5mm2). 4 Insulation dielectric strength test
Ambient temperature: 23±5℃.
Relative humidity: 65±5%.
Apply AC voltage of 1000V (frequency of 50Hz) between the contacts and between the contacts and the shell, and there is no breakdown after 1min. 5 Vibration and impact resistance test
5.1 Vibration resistance test
Vibration frequency: 50Hz.
Maximum acceleration (maximum deceleration): 59. Vibration time: 4h.
5.2 Impact resistance test
Maximum acceleration (maximum deceleration): 10g. Number of impacts: 10000 times. Www.bzxZ.net
No mechanical damage shall occur after the test. 6 Temperature resistance test
Initial temperature: 23±5℃.
Raise the temperature to 70±2℃, keep warm for 15min, cool to -25±3℃, keep warm for 15min. After the above temperature cycle, the electrical connector shall also undergo vibration and impact resistance test, maximum allowable voltage drop test, and insulation dielectric strength test, and no visible cracks or deformation shall occur. Additional notes:
This standard was proposed by the Ministry of Communications of the People's Republic of China and is under the jurisdiction of the Standardization and Metrology Institute of the Ministry of Communications. This standard was drafted by the Highway Research Institute of the Ministry of Communications. The main drafter of this standard is Wang Lilin.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test methods and requirements of electrical connections between motor yehicles and towed vehicles
This standard specifies the test methods and requirements of electrical connectors between motor yehicles and towed vehicles. UDC 629.11.013
.5: 621.315
GB 5053.3--85
This standard applies to 12N, 12S, 24N and 24S electrical connectors for vehicles with rated voltages of 6V, 12V and 24V.
This standard is equivalent to the international standard ISO4091-1978 "Road vehicles-Electrical connectors between towing vehicles and trailers-Test methods and requirements".
1 Insertion force and withdrawal force test
Ambient temperature: 23±5℃.
The plug and plug tube should be dry and clean.
The static test method (static gravity method) is used for the tenth plugging and unplugging. Insertion force: maximum 200N.
Pull-out force: maximum 200N.
Minimum 20N.
2 Current carrying capacity test
Ambient temperature: 23±5℃.
Two adjacent contacts shall not be tested at the same time. Each contact shall be able to continuously pass a direct current of 15A. During the test, the contact under test and the common circuit contact form a circuit, through which a direct current of 15A is passed for 1h. The temperature rise of the plug and plug tube near the insulator shall not exceed 20℃. In the test circuit, the length of the wire connected to the terminal is at least 1m, and the cross-sectional area is 1.5mm2. 3 Maximum allowable voltage drop test
Ambient temperature: 23±5℃.
The voltage drop between the plug and the corresponding plug shall be measured at the tenth insertion, with a current of 10A. 3.1 For electrical connectors whose cables are not die-cast into sockets and plugs, the following voltage drops shall be measured: 3.1.1 The voltage drop between each plug and the terminal of the corresponding plug shall not exceed 5mV/A. 3.1.2 The voltage drop between each terminal and the connecting wire at a distance of 10mm from the terminal shall not exceed 0.5mV/A (the cross-sectional area of the wire is 1.5mm2).
3.2 For electrical connectors whose cables are only die-cast into sockets or only die-cast into plugs, the following voltage drops shall be measured: 3.2.1 The voltage drop between each pluggable terminal and the connecting wire of the corresponding plug (or plug) at a distance of 100mm from the end face of the socket (or plug) shall not exceed 5.5mV/A (the cross-sectional area of the wire is 1.5mm2). 3.2.2 The voltage drop between each pluggable terminal and the connecting wire at 10mm from the terminal shall not exceed 0.5mV/A (the cross-sectional area of the wire is 1.5mm2).
National Bureau of Standards Issued on March 9, 1985
Implementation on February 1, 1986
GB 5053.385
3.3 For the electrical connector of the cable line, which is a die-cast socket and plug, the voltage drop of each pair of corresponding connecting wires at 100mm from the end face of the socket and plug shall not exceed 6mV/A (the cross-sectional area of the wire is 1.5mm2). 4 Insulation dielectric strength test
Ambient temperature: 23±5℃.
Relative humidity: 65±5%.
Apply AC voltage of 1000V (frequency of 50Hz) between the contacts and between the contacts and the shell, and there is no breakdown after 1min. 5 Vibration and impact resistance test
5.1 Vibration resistance test
Vibration frequency: 50Hz.
Maximum acceleration (maximum deceleration): 59. Vibration time: 4h.
5.2 Impact resistance test
Maximum acceleration (maximum deceleration): 10g. Number of impacts: 10000 times. Www.bzxZ.net
No mechanical damage shall occur after the test. 6 Temperature resistance test
Initial temperature: 23±5℃.
Raise the temperature to 70±2℃, keep warm for 15min, cool to -25±3℃, keep warm for 15min. After the above temperature cycle, the electrical connector shall also undergo vibration and impact resistance test, maximum allowable voltage drop test, and insulation dielectric strength test, and no visible cracks or deformation shall occur. Additional notes:
This standard was proposed by the Ministry of Communications of the People's Republic of China and is under the jurisdiction of the Standardization and Metrology Institute of the Ministry of Communications. This standard was drafted by the Highway Research Institute of the Ministry of Communications. The main drafter of this standard is Wang Lilin.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 2460-1996 Sampling and sample preparation methods for pyrite and sulphur concentrate
- GB 4706.33-2003 Safety of household and similar electrical appliances Particular requirements for commercial electric deep fat fryers
- HG/T 2712-1995 Determination of viscosity of liquid and solution phenolic resins
- GB 4333.4-1988 Chemical analysis methods for ferrosilicon - The chrome azurol S photometric method for the determination of aluminum content
- GB/T 19100-2003 Terminology work—Establishment of concep system
- GB 2523-1990 Cold rolled steel sheet (strip) surface roughness measurement method
- GB/T 19354-2003 Vitreous and porcelain enamels for aluminium—Determination of the adhesion of enamels on aluminium under the action of electrolytic solution(spall test)
- GB/T 4215-1984 Determination of sound power level of noise from metal cutting machine tools
- GB/T 19617-2004 Test method for cotton length - Hand-pulling ruler method
- HG 2725-1995 Bulk carbon black sampling method
- GB/T 8116-1987 Types and basic parameters of wind turbine generator sets
- GB 12514-1990 Fire protection interface performance requirements and test methods
- JB/T 9979-1999 Technical requirements for chain shot blasting cleaning rooms
- GB/T 4958.4-1988 Measurement methods for equipment used in terrestrial radio-relay systems Part 2: Measurement of subsystems Section 1: General
- GB/T 18816-2002 General technical requirements for marine heat exchangers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com