JB/T 6885-1993 Ventilator circular flange dimensions
time:
1993-07-13 15:00:00
- JB/T 6885-1993
- Abolished
Standard ID:
JB/T 6885-1993
Standard Name:
Ventilator circular flange dimensions
Chinese Name:
通风机 圆形法兰尺寸
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-07-13 -
Date of Implementation:
1994-07-01 -
Date of Expiration:
2005-04-15
China Standard Classification Number:
Machinery>>General Machinery and Equipment>>J72 Compressor, Fan

Skip to download
Summary:
This standard specifies the dimensions of circular flanges of general-purpose ventilators. This standard is applicable to general-purpose air machines and their pipe network usage that convey non-toxic, unsaturated, non-corrosive, non-flammable, non-abrasive particles and a temperature not exceeding 80°C (not exceeding 40°C if the motor or fan bearing is in the air flow). orchid. This standard does not apply to large, special-purpose ventilators with larger flange thicknesses. JB/T 6885-1993 Ventilator circular flange dimensions JB/T6885-1993 Standard download and decompression password: www.bzxz.net

Some standard content:
Machinery Industry Standard of the People's Republic of China||tt ||Dimensions of round flange of ventilators
Subject content and scope of application
This standard specifies the dimensions of round flanges of general-purpose ventilators. JB/T6885--93
This standard is suitable for conveying non-toxic, unsaturated, non-corrosive, non-flammable, non-abrasive particles and the temperature does not exceed 80C (if the motor or fan bearing is in the air flow, it does not exceed 40℃ 》Flanges for air ventilators and their pipe networks. This standard does not apply to large-scale, special-purpose ventilators with larger flange thicknesses. 2 Reference standard
GB95--85 Flat Washer Class C||tt ||GB 97.185 Flat Washer—Grade A
GB97.2-85 Flat Washer Chamfer Type—Grade A
GB321—80 Priority Number and Priority Number System
3 Technical Requirements| |tt||3.1 The size of the impeller outer diameter should comply with the R20 basic series given in GB321. For medium-sized ventilators, it is recommended to use the R40 basic series (Appendix A). In special cases, the increase in the impeller outer diameter size is smaller. The fan is allowed to use R80 to supplement the series values. 3.2 The number of flange holes should be an integer divisible by 4, and should be arranged equidistantly from the pitch circle line coaxial with the outer axis of the impeller. The casing is divided into two parts, allowing the flange to be divided into two halves. 3.3 The gasket should be selected according to GB97.1, GB97.2 or GB95. 3.4 The specifications of the general purpose ventilator are marked with the outer diameter of the wheel (i.e. the nominal diameter of the ventilator). Diameter design ventilator. The nominal diameter adopts R20 series. The specifications of ventilators from 100mm to 2000mm are as shown in Table 1. Table 1 Impeller outer diameter (ie nominal diameter of ventilator) D100
125| |tt||140
315||tt ||355
Impeller diameter greater than 2000mm, R20.R40 or R80 series can also be used. 3.5 flange and assembly hole dimensions (see the figure and table 2 below) Approved by the Ministry of Machinery Industry of the People's Republic of China on 1993-07-13 332
mm| |tt||1994-07-01 Implementation
140||tt| |160
1000|| tt||1120
120||tt| |137
770|| tt||860
1880||tt| |2080
JB/ T6885—93
Table 2
22.5||tt| |18
30|| tt||mm
Thickness
(reference)
333|| tt||F
1250|| tt||1400
315||tt| |335
850|| tt||900
1320||tt| |1400
Additional notes: ||tt| |di
770|| tt||810Www.bzxZ.net
1190||tt| |1250
2| |tt||20
JB/T 6885-93
Appendix A||tt ||(reference)
Table A1
N pieces
This standard is proposed by the National Technical Committee for Fan Standardization. This standard is drafted and managed by Shenyang Blower Research Institute. The main drafters of this standard are: Chen Mingliang and Tian Suwen. This standard is equivalent to ISO65801 "General Industrial Fan - 334
18|| tt||15
10||tt| |12
Size》No. 1 in 1981 Version.
Circular flange one
Thickness (test)
5| |tt||6
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Subject content and scope of application
This standard specifies the dimensions of round flanges of general-purpose ventilators. JB/T6885--93
This standard is suitable for conveying non-toxic, unsaturated, non-corrosive, non-flammable, non-abrasive particles and the temperature does not exceed 80C (if the motor or fan bearing is in the air flow, it does not exceed 40℃ 》Flanges for air ventilators and their pipe networks. This standard does not apply to large-scale, special-purpose ventilators with larger flange thicknesses. 2 Reference standard
GB95--85 Flat Washer Class C||tt ||GB 97.185 Flat Washer—Grade A
GB97.2-85 Flat Washer Chamfer Type—Grade A
GB321—80 Priority Number and Priority Number System
3 Technical Requirements| |tt||3.1 The size of the impeller outer diameter should comply with the R20 basic series given in GB321. For medium-sized ventilators, it is recommended to use the R40 basic series (Appendix A). In special cases, the increase in the impeller outer diameter size is smaller. The fan is allowed to use R80 to supplement the series values. 3.2 The number of flange holes should be an integer divisible by 4, and should be arranged equidistantly from the pitch circle line coaxial with the outer axis of the impeller. The casing is divided into two parts, allowing the flange to be divided into two halves. 3.3 The gasket should be selected according to GB97.1, GB97.2 or GB95. 3.4 The specifications of the general purpose ventilator are marked with the outer diameter of the wheel (i.e. the nominal diameter of the ventilator). Diameter design ventilator. The nominal diameter adopts R20 series. The specifications of ventilators from 100mm to 2000mm are as shown in Table 1. Table 1 Impeller outer diameter (ie nominal diameter of ventilator) D100
125| |tt||140
315||tt ||355
Impeller diameter greater than 2000mm, R20.R40 or R80 series can also be used. 3.5 flange and assembly hole dimensions (see the figure and table 2 below) Approved by the Ministry of Machinery Industry of the People's Republic of China on 1993-07-13 332
mm| |tt||1994-07-01 Implementation
140||tt| |160
1000|| tt||1120
120||tt| |137
770|| tt||860
1880||tt| |2080
JB/ T6885—93
Table 2
22.5||tt| |18
30|| tt||mm
Thickness
(reference)
333|| tt||F
1250|| tt||1400
315||tt| |335
850|| tt||900
1320||tt| |1400
Additional notes: ||tt| |di
770|| tt||810Www.bzxZ.net
1190||tt| |1250
2| |tt||20
JB/T 6885-93
Appendix A||tt ||(reference)
Table A1
N pieces
This standard is proposed by the National Technical Committee for Fan Standardization. This standard is drafted and managed by Shenyang Blower Research Institute. The main drafters of this standard are: Chen Mingliang and Tian Suwen. This standard is equivalent to ISO65801 "General Industrial Fan - 334
18|| tt||15
10||tt| |12
Size》No. 1 in 1981 Version.
Circular flange one
Thickness (test)
5| |tt||6
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- FZ/T 71004-2003 Combed and braided wool yarn
- JB/T 51065-1999 Milk separator product quality classification
- GA 27-2002 Regulations on Risk Levels and Safety Protection Levels for Museums in the Cultural Heritage System
- GB 3738.1-1983 Compression-type right-angle pipe fittings
- JB/T 5145.3-1991 Test methods for oil-injected screw single-stage refrigeration compression condensing units
- GB/T 8424.2-2001 Textiles - Colour fastness tests - Instrumental evaluation method for relative whiteness
- JB/T 2775-1992 PN16.0~32.0MPa nuts
- HG 20546.1-1992 Chemical plant equipment layout design content and depth regulations
- QB/T 2180-1995 Bicycle saddle pipe
- SJ 20706-1998 PCI local bus specification
- SL/T 220-1998 Determination of trace copper, zinc, cadmium and lead in water - Flow injection atomic absorption spectrophotometry SL/T 220-98
- JB/T 7288-1994 Basic parameters of drum type grass cutter series
- HG/T 2722-1995 Monoisopropylamine
- JB/T 6664.2-1993 Technical conditions of self-priming pump
- GB/T 16693-1996 Hose quick connector
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com