GB/T 5547-1985 Determination of viscosity of resin finishing agents
time:
2024-08-04 15:49:18
- GB/T 5547-1985
- Abolished
Standard ID:
GB/T 5547-1985
Standard Name:
Determination of viscosity of resin finishing agents
Chinese Name:
树脂整理剂 粘度的测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1985-10-29 -
Date of Implementation:
1986-08-01 -
Date of Expiration:
2008-06-01
Standard ICS number:
Textile and leather technology >> 59.040 Textile auxiliary materialsChina Standard Classification Number:
Chemicals>>Coatings, Pigments, Dyes>>G55 Basic Standards and General Methods for Dyes
alternative situation:
Replaced by GB/T 5547-2007
Review date:
2004-10-14Drafting Organization:
Dalian Light Industry Research InstituteFocal point Organization:
National Dye Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
This standard is applicable to the determination of absolute viscosity of resin finishing agents. GB/T 5547-1985 Determination of viscosity of resin finishing agents GB/T5547-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Determinatlon of the viscosity This standard applies to the determination of absolute viscosity of resin finishing agents. 1 Definition
UDC 678.044.33
GB 5547—85
Viscosity is the internal friction of a fluid, the resistance of a layer of fluid to relative motion with another layer of fluid, expressed in moire. 2 Instruments and Equipment
2.1 Rotational viscometer: measurement error is less than ±0.5%. 2.2 Super thermostatic bath: temperature fluctuation range is less than ±0.5℃. 2.3 Thermometer: graduation 0.1℃.
2.4 Container: a container with a diameter of 6 to 7 cm and a height of not less than 11 cm or a container attached to a rotational viscometer. 2.5 Stopwatch: accuracy 0.2 seconds.
3 Determination procedures
3.1 According to the viscosity of the sample, select an appropriate rotor and rotation speed so that the reading is within the range of 20-85% of the dial. 3.2 Immerse the rotor vertically into the center of the sample so that the liquid surface reaches the rotor level mark. 3.3 Keep the sample and rotor in the test container at a constant temperature of 25±0.5℃ and keep the sample temperature uniform. 3.4 Read the indicated value when the rotor rotates for 60±2 seconds. 3.5 Calculate the average value of the results of two parallel tests according to the instrument requirements. Additional notes:
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Shenyang Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Dalian Light Chemical Industry Research Institute. The main drafter of this standard is Jin Liwen.
Published by the National Bureau of Standards on October 29, 1985bZxz.net
Implementation on August 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Determinatlon of the viscosity This standard applies to the determination of absolute viscosity of resin finishing agents. 1 Definition
UDC 678.044.33
GB 5547—85
Viscosity is the internal friction of a fluid, the resistance of a layer of fluid to relative motion with another layer of fluid, expressed in moire. 2 Instruments and Equipment
2.1 Rotational viscometer: measurement error is less than ±0.5%. 2.2 Super thermostatic bath: temperature fluctuation range is less than ±0.5℃. 2.3 Thermometer: graduation 0.1℃.
2.4 Container: a container with a diameter of 6 to 7 cm and a height of not less than 11 cm or a container attached to a rotational viscometer. 2.5 Stopwatch: accuracy 0.2 seconds.
3 Determination procedures
3.1 According to the viscosity of the sample, select an appropriate rotor and rotation speed so that the reading is within the range of 20-85% of the dial. 3.2 Immerse the rotor vertically into the center of the sample so that the liquid surface reaches the rotor level mark. 3.3 Keep the sample and rotor in the test container at a constant temperature of 25±0.5℃ and keep the sample temperature uniform. 3.4 Read the indicated value when the rotor rotates for 60±2 seconds. 3.5 Calculate the average value of the results of two parallel tests according to the instrument requirements. Additional notes:
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Shenyang Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Dalian Light Chemical Industry Research Institute. The main drafter of this standard is Jin Liwen.
Published by the National Bureau of Standards on October 29, 1985bZxz.net
Implementation on August 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY 5509-1992 POI-2420 Crude Oil Demulsifier
- GB/T 18391.4-2001 Information technology--Specification and STANDARDization of data elements--Part 4:Rules and guidelines for the formulation of data definitions
- GB/T 3478.1-1995 Basic profile tolerances for cylindrical spur involute splines
- JB/T 8139-1999 Low voltage cables (wires) for road vehicles
- HG/T 21578-1994 Pipeline Vibration Damper
- GB/T 2856.2-1990 Die rolling guide die seat diagonal guide column lower die seat
- SN/T 0547-1996 Rules of inspection for import and export tobacco leaf
- GB/T 15464-1995 仪器仪表包装通用技术条件
- GB/T 14860-1993 General specification for transformers and inductors for communication and electronic equipment
- GB 5198.2-1996 Antibiotic glass bottle caps Part 2: Aluminum-plastic combination caps
- JB/T 9114-1999 Rotary flatbed letterpress printing press
- GB/T 3510-1992 Determination of plasticity of raw rubber and rubber mixes - Rapid plasticometer method
- GB/T 5737-1995 Plastic container for food
- JB/T 3697.1-1999 Accuracy inspection of radial milling machines
- GB/T 14978-1994 Continuously hot-dip aluminum-zinc-silicon alloy coated steel strip and steel sheet
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com