GB/T 5547-1985 Determination of viscosity of resin finishing agents
time:
2024-08-04 15:49:18
- GB/T 5547-1985
- Abolished
Standard ID:
GB/T 5547-1985
Standard Name:
Determination of viscosity of resin finishing agents
Chinese Name:
树脂整理剂 粘度的测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1985-10-29 -
Date of Implementation:
1986-08-01 -
Date of Expiration:
2008-06-01
Standard ICS number:
Textile and leather technology >> 59.040 Textile auxiliary materialsChina Standard Classification Number:
Chemicals>>Coatings, Pigments, Dyes>>G55 Basic Standards and General Methods for Dyes
alternative situation:
Replaced by GB/T 5547-2007
Review date:
2004-10-14Drafting Organization:
Dalian Light Industry Research InstituteFocal point Organization:
National Dye Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
This standard is applicable to the determination of absolute viscosity of resin finishing agents. GB/T 5547-1985 Determination of viscosity of resin finishing agents GB/T5547-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Determinatlon of the viscosity This standard applies to the determination of absolute viscosity of resin finishing agents. 1 Definition
UDC 678.044.33
GB 5547—85bzxz.net
Viscosity is the internal friction of a fluid, the resistance of a layer of fluid to relative motion with another layer of fluid, expressed in moire. 2 Instruments and Equipment
2.1 Rotational viscometer: measurement error is less than ±0.5%. 2.2 Super thermostatic bath: temperature fluctuation range is less than ±0.5℃. 2.3 Thermometer: graduation 0.1℃.
2.4 Container: a container with a diameter of 6 to 7 cm and a height of not less than 11 cm or a container attached to a rotational viscometer. 2.5 Stopwatch: accuracy 0.2 seconds.
3 Determination procedures
3.1 According to the viscosity of the sample, select an appropriate rotor and rotation speed so that the reading is within the range of 20-85% of the dial. 3.2 Immerse the rotor vertically into the center of the sample so that the liquid surface reaches the rotor level mark. 3.3 Keep the sample and rotor in the test container at a constant temperature of 25±0.5℃ and keep the sample temperature uniform. 3.4 Read the indicated value when the rotor rotates for 60±2 seconds. 3.5 Calculate the average value of the results of two parallel tests according to the instrument requirements. Additional notes:
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Shenyang Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Dalian Light Chemical Industry Research Institute. The main drafter of this standard is Jin Liwen.
Published by the National Bureau of Standards on October 29, 1985
Implementation on August 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Determinatlon of the viscosity This standard applies to the determination of absolute viscosity of resin finishing agents. 1 Definition
UDC 678.044.33
GB 5547—85bzxz.net
Viscosity is the internal friction of a fluid, the resistance of a layer of fluid to relative motion with another layer of fluid, expressed in moire. 2 Instruments and Equipment
2.1 Rotational viscometer: measurement error is less than ±0.5%. 2.2 Super thermostatic bath: temperature fluctuation range is less than ±0.5℃. 2.3 Thermometer: graduation 0.1℃.
2.4 Container: a container with a diameter of 6 to 7 cm and a height of not less than 11 cm or a container attached to a rotational viscometer. 2.5 Stopwatch: accuracy 0.2 seconds.
3 Determination procedures
3.1 According to the viscosity of the sample, select an appropriate rotor and rotation speed so that the reading is within the range of 20-85% of the dial. 3.2 Immerse the rotor vertically into the center of the sample so that the liquid surface reaches the rotor level mark. 3.3 Keep the sample and rotor in the test container at a constant temperature of 25±0.5℃ and keep the sample temperature uniform. 3.4 Read the indicated value when the rotor rotates for 60±2 seconds. 3.5 Calculate the average value of the results of two parallel tests according to the instrument requirements. Additional notes:
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Shenyang Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Dalian Light Chemical Industry Research Institute. The main drafter of this standard is Jin Liwen.
Published by the National Bureau of Standards on October 29, 1985
Implementation on August 1, 1986
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 6939.2-2004 Controllers for off-grid wind turbines Part 2: Test methods
- SJ 20676-1998 General specification for solid-state broadband power amplifier modules for communication countermeasures
- JB/T 8023.1-1999 Knurled handles for machine tool fixture parts and components
- GB/T 5009.100-2003 Analytical methods for hygienic standards of expanded polystyrene products for food packaging
- SY/T 5324-1994 Prestressed Insulated Oil Pipe
- JB/T 51192-1999 Agricultural screw oil press product quality classification
- GB/T 3543.4-1995 Inspection procedures for crop seeds Germination test
- GB/T 8177-2004 Two-point internal micrometer
- GB/T 5009.107-2003 Determination of diazinon residues in plant-derived foods
- HG/T 2765.5-1996 Silicone test method
- GB/T 16830-1997 Bar code in dispatch unit
- SJ 20709-1998 Format and encoding of military vector digital map files
- GB/T 3653.4-1988 Chemical analysis methods for ferroboron - EDTA volumetric method for determination of aluminum content
- JB/T 7220-1994 Scraper discharge centrifuge
- HG 2161-1991 Tricyclazole wettable powder
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com