GB/T 15080.4-1994 Chemical analysis methods for antimony concentrates - Determination of warm water content
time:
2024-08-09 01:32:14
- GB/T 15080.4-1994
- Abolished
Standard ID:
GB/T 15080.4-1994
Standard Name:
Chemical analysis methods for antimony concentrates - Determination of warm water content
Chinese Name:
锑精矿化学分析方法 温存水量的测定
Standard category:
National Standard (GB)
-
Date of Release:
1994-05-11 -
Date of Implementation:
1994-01-02 -
Date of Expiration:
2007-09-29
Standard ICS number:
Mining and mineral products >> 73.060 Metal oresChina Standard Classification Number:
Mining>>Nonferrous Metal Minerals>>D42 Heavy Metal Minerals
alternative situation:
Adjusted to YS/T 556.4-2006
Review date:
2004-10-14Drafting Organization:
Xikuangshan Mining BureauFocal point Organization:
National Technical Committee for Standardization of Nonferrous MetalsPublishing Department:
China Nonferrous Metals Industry AssociationCompetent Authority:
China Nonferrous Metals Industry Association

Skip to download
Summary:
GB/T 15080.4-1994 Chemical analysis method for antimony concentrates Determination of moisture content at room temperature GB/T15080.4-1994 standard download decompression password: www.bzxz.net

Some standard content:
UDC 669.754 : 543. 06
National Standard of the People's Republic of China
GB/T15080.1~15080.9--94
Methods for chemical analysis of antimony concentrates
Issued on 1994-05-11
Implemented on 1994-12-01
State Bureau of Technical Supervision
National Standard of the People's Republic of China
Methods for chemical analysis of antimony concentrates
Determination of hygroscopic moisture
Antimony concentrates-Determination of hygroscopic moisture
Subject content and scope of application
This standard specifies the method for the determination of hygroscopic moisture content in antimony concentrate. This standard is applicable to the determination of hygroscopic moisture content in antimony concentrate. Determination range: 0.1%~~~12%. 2 Reference standards
GB1.4 Standardization work guidelines Chemical analysis method standard preparation regulations GB1467 General principles and general provisions for chemical analysis methods for metallurgical products GB7146 Sampling and sample preparation methods for bagged ores
3 Method summary
The sample is dried at 100~105℃, and the wet water content is determined by weight method. 4 Instruments
4.1 Balance, sensitivity 1mg.
4.2 Balance, sensitivity 0.5g.
4.3 Weighing bottle, 60mm×35mm.
4.4 Drying tray, a rectangular anti-corrosion metal tray with a bottom area of 300~500cm2. 4.5 Electric constant temperature drying oven, which can maintain a temperature of 100105℃. 5 Laboratory samples
5.1 For powder concentrate samples, the particle size should be less than 0.2 mm. 5.2 For lump concentrate samples, the moisture determination samples should be prepared according to GB7146 and stored in a sealed container. 6 Analysis steps
6.1 Test materials
6.1.1 For powder concentrate, weigh 10.000 g of laboratory sample using a balance (4.1) with an accuracy of 0.001 g. 6.1.2 For lump concentrate, weigh 1000.0 g of sample using a balance (4.2) with an accuracy of 0.5 g. Perform two independent measurements and take the average value. 6.2 Determination
6.2.1 Determination of moisture content in powder concentrate Approved by the State Administration of Technical Supervision on May 11, 1994 GB/T 15080.4-94
Implementation on December 1, 1994
GB/T 15080.4-94
Spread the sample (6.1.1) evenly in a weighing bottle (4.3) that has been dried to constant weight at 100-105℃ in advance, dry it in an electric constant temperature drying oven (4.5) at 100-105℃ for 2h, take it out, cool it to room temperature in a desiccator, and weigh it. Repeat the drying for 3Jmin until constant weight (the difference between two consecutive weighings is not more than 0.002g). 6.2.2 Determination of wet water content in lump concentrate Spread the sample (6.1.2) evenly on a drying tray (4.4) of known weight, dry it in an electric constant temperature drying oven (4.5) at 100-105℃ for 2h, take it out, cool it to room temperature in the drying oven, and weigh it. Repeat the drying for 30min until constant weight is reached (i.e. the difference between two consecutive weighings is not greater than 0.5g).
7 Expression of analysis results
Calculate the percentage of wet water content according to the following formula: m = m2 × 100
HO(%) =
Mass of sample weighing container·g:
Where: m. -
mt-Total mass of sample and sample weighing container before drying, g, m2~-Total mass of sample and sample weighing container after drying, g. The result is expressed to two decimal places.
8 Allowable Difference
The difference in analysis results between laboratories should not be greater than the allowable difference listed in the following table. %
Wet storage water content
1. 00~5. 00wwW.bzxz.Net
>5. 00~12. 00
Additional remarks:
This standard is proposed by China Nonferrous Metals Industry Corporation. This standard is technically managed by Beijing Research Institute of Mining and Metallurgy. This standard is drafted by Xikuangshan Mining Bureau and Hunan Nonferrous Metals Research Institute. This standard is drafted by Xikuang Mining Bureau.
The main drafters of this standard are Xie Benchang and Zeng Fusheng. 14
Allowable Difference
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
GB/T15080.1~15080.9--94
Methods for chemical analysis of antimony concentrates
Issued on 1994-05-11
Implemented on 1994-12-01
State Bureau of Technical Supervision
National Standard of the People's Republic of China
Methods for chemical analysis of antimony concentrates
Determination of hygroscopic moisture
Antimony concentrates-Determination of hygroscopic moisture
Subject content and scope of application
This standard specifies the method for the determination of hygroscopic moisture content in antimony concentrate. This standard is applicable to the determination of hygroscopic moisture content in antimony concentrate. Determination range: 0.1%~~~12%. 2 Reference standards
GB1.4 Standardization work guidelines Chemical analysis method standard preparation regulations GB1467 General principles and general provisions for chemical analysis methods for metallurgical products GB7146 Sampling and sample preparation methods for bagged ores
3 Method summary
The sample is dried at 100~105℃, and the wet water content is determined by weight method. 4 Instruments
4.1 Balance, sensitivity 1mg.
4.2 Balance, sensitivity 0.5g.
4.3 Weighing bottle, 60mm×35mm.
4.4 Drying tray, a rectangular anti-corrosion metal tray with a bottom area of 300~500cm2. 4.5 Electric constant temperature drying oven, which can maintain a temperature of 100105℃. 5 Laboratory samples
5.1 For powder concentrate samples, the particle size should be less than 0.2 mm. 5.2 For lump concentrate samples, the moisture determination samples should be prepared according to GB7146 and stored in a sealed container. 6 Analysis steps
6.1 Test materials
6.1.1 For powder concentrate, weigh 10.000 g of laboratory sample using a balance (4.1) with an accuracy of 0.001 g. 6.1.2 For lump concentrate, weigh 1000.0 g of sample using a balance (4.2) with an accuracy of 0.5 g. Perform two independent measurements and take the average value. 6.2 Determination
6.2.1 Determination of moisture content in powder concentrate Approved by the State Administration of Technical Supervision on May 11, 1994 GB/T 15080.4-94
Implementation on December 1, 1994
GB/T 15080.4-94
Spread the sample (6.1.1) evenly in a weighing bottle (4.3) that has been dried to constant weight at 100-105℃ in advance, dry it in an electric constant temperature drying oven (4.5) at 100-105℃ for 2h, take it out, cool it to room temperature in a desiccator, and weigh it. Repeat the drying for 3Jmin until constant weight (the difference between two consecutive weighings is not more than 0.002g). 6.2.2 Determination of wet water content in lump concentrate Spread the sample (6.1.2) evenly on a drying tray (4.4) of known weight, dry it in an electric constant temperature drying oven (4.5) at 100-105℃ for 2h, take it out, cool it to room temperature in the drying oven, and weigh it. Repeat the drying for 30min until constant weight is reached (i.e. the difference between two consecutive weighings is not greater than 0.5g).
7 Expression of analysis results
Calculate the percentage of wet water content according to the following formula: m = m2 × 100
HO(%) =
Mass of sample weighing container·g:
Where: m. -
mt-Total mass of sample and sample weighing container before drying, g, m2~-Total mass of sample and sample weighing container after drying, g. The result is expressed to two decimal places.
8 Allowable Difference
The difference in analysis results between laboratories should not be greater than the allowable difference listed in the following table. %
Wet storage water content
1. 00~5. 00wwW.bzxz.Net
>5. 00~12. 00
Additional remarks:
This standard is proposed by China Nonferrous Metals Industry Corporation. This standard is technically managed by Beijing Research Institute of Mining and Metallurgy. This standard is drafted by Xikuangshan Mining Bureau and Hunan Nonferrous Metals Research Institute. This standard is drafted by Xikuang Mining Bureau.
The main drafters of this standard are Xie Benchang and Zeng Fusheng. 14
Allowable Difference
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 4120.3-1992 Determination of acidity in industrial liquid methyl chloride products Titration method
- QB/T 2626.1-2004 General technical requirements for needle plates of industrial sewing machines Part 1: Needle plates for lockstitch sewing machines
- SJ 20042-1992 Methods of measurement for tropsphering scattering communication equipment
- GB/T 8427-1998 Textiles - Tests for colour fastness - Colour fastness to artificial light: Xenon arc fading lamp
- HG 2676-1995 4% Gibberellic Acid EC
- GB/T 11444.3-1989 Technical requirements for transmitting, receiving and ground communication equipment of domestic satellite communication earth stations Part 3: Television/FM equipment
- HG/T 20636.8-1998 Quality Assurance Procedure for Automation Engineering Design
- HG/T 20702.6-2000 Format and preparation instructions for special equipment professional equipment data sheets
- JB/T 8838.2-2000 Test methods for small flour processing equipment
- JB/T 8004.9-1999 Machine tool fixture parts and components Swivel handle nuts
- GB/T 2855.2-1990 Die sliding guide die seat diagonal guide column lower die seat
- GB 12557-2000 General safety rules for woodworking machine tools
- SY 5510-1992 Common terms in oilfield chemistry
- GB 2728-1981 Hygienic Standard for Braised Meat
- GB/T 40058-2021 Coding specification for the national fixed assets investment projects
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com