YC/T 37.1-2002 Determination of physical properties of filter rods Part 1: Length electro-optical method
time:
2024-08-09 17:24:59
- YC/T 37.1-2002
- in force
Standard ID:
YC/T 37.1-2002
Standard Name:
Determination of physical properties of filter rods Part 1: Length electro-optical method
Chinese Name:
滤棒物理性能的测定 第1部分:长度 电光法
Standard category:
Tobacco Industry Standard (YC)
-
Date of Release:
2002-05-14 -
Date of Implementation:
2002-07-01
Standard ICS number:
Agriculture >> 65.160 Tobacco, tobacco products and tobacco industry equipmentChina Standard Classification Number:
Food>>Cigarette Making>>X85 Cigarette Making Comprehensive
alternative situation:
YC/T 37.1-1996
publishing house:
China Standards PressISBN:
155066.2-14542Publication date:
2004-04-24
Drafting Organization:
National Tobacco Standardization Technical Committee (TC44)Focal point Organization:
National Tobacco Standardization Technical Committee (TC44)Publishing Department:
State Tobacco Monopoly Administration
Skip to download
Summary:
This part of YC/T 37 specifies the method for determining the length of filter rods. This part is applicable to all kinds of filter rods. YC/T 37.1-2002 Determination of physical properties of filter rods Part 1: Electro-optical length method YC/T37.1-2002 Standard download decompression password: www.bzxz.net
Some standard content:
ICS65.160
Registration number: 10497—2002
Tobacco Industry Standard of the People's Republic of China
YC/T 37. 1 ---2002
Replaces YC/T37.1--1996
Test of filters physical characteristics--Part 1 :Length-Photoelectricity method2002-05-14 Issued
State Tobacco Monopoly Administration
Implementation on 2002-07-01
YC/T 37. 1--2002
This part is the first part of the YC/T37 "Determination of physical properties of filter rods" series of standards. This series of standards consists of seven parts: Determination of physical properties of filter rods Part 1: Length photoelectric method Part 2: Circumference Determination of physical properties of filter rods Laser method Determination of physical properties of filter rods Part 3: Absorption resistance Part 4: Hardness Determination of physical properties of filter rods Determination of physical properties of filter rods Part 5: Moisture Determination of physical properties of filter rods Part 6: Roundness Determination of physical properties of filter rods Part 7: Appearance This part replaces YC/T37.1-1996 "Determination of physical properties of filter rods Part 1: Length". The main changes of this part compared with YC/T37.1-1996 are as follows: Addition of the photoelectric method for determining the length of filter rods; Adjustment of YC/T 37.1-1996 to Appendix A. Appendix A of this part is an informative appendix.
This part was proposed by the State Tobacco Monopoly Administration. This part is under the jurisdiction of the National Tobacco Standardization Technical Committee (TC44). The drafting unit of this part is the National Tobacco Quality Supervision and Inspection Center. The main drafters of this part are Zhou Decheng, Li Xiaohui, Feng Xiaomin, Wang Yunfang and Zhao Hang. The previous versions of the standard replaced by this part are: YC/T37.1—1996. 548
1 Scope
Determination of physical properties of filter rods
Part 1: Length photoelectric methodwwW.bzxz.Net
This part of YC/T37 specifies the method for determining the length of filter rods. This part is applicable to various filter rods.
2 Normative references
YC/T 37. 1—2002
The clauses in the following documents become the clauses of this part through reference in this part of YC/T37. For dated references, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest versions apply to this part. GB/T16447 Atmospheric environment for conditioning and testing of tobacco and tobacco products (idtISO3402) 3 Principle of measurement
Use parallel light beams to project or scan the end of the filter rod to form a light signal, which is received by the photoelectric receiving device and processed by the data processing system to give the length value of the filter rod.
4 Instruments and equipment
4.1 Photoelectric length measuring instruments should meet the following requirements: automatic feeding;
Optical system that can generate parallel light beams (laser or ordinary light); capable of multi-point measurement of the end of the sample;
A photoelectric receiving device that can receive the signal at each measuring point; The data processing system can perform statistics on each measurement data and give the sample length value as the arithmetic mean; The accuracy of the instrument measurement result is 0.05mm. 4.2 Standard rod, accuracy is 0.005mm. 5 Measurement steps
Adjust the sample according to GB/T16447 and test under corresponding environmental conditions. 5.1 Turn on the power and adjust the instrument according to the instrument operating procedures. 5.2 According to the specifications of the sample, select a standard rod of corresponding length and calibrate the standard push length of the instrument. 5.3 Place the filter rod in the measuring position so that the parallel light beam shines on the end of the filter rod, and project or scan the end of the filter rod. 5.4 The filter rod length value is given by the photoelectric receiving device and the data processing system. 5.5 Repeat steps 5.3 to 5.4 and test a total of 30 samples. 6 Result expression
The measurement results are expressed in millimeters, accurate to 0.1 mm. 7 Measurement report
The measurement report shall include the following contents:
YC/T37.1—2002
The number of this part of YC/T37;
The mark and description of the sample;
The measurement time, the instrument and model used; the environmental conditions of the measurement and the measurement results.
A.1 Measurement principle
Appendix A
(Informative appendix)
Measurement of filter length by projection method
YC/T37.1—2002
Using the method of parallel light projection, the magnified image is compared with the "standard sample" to measure the length of the sample. A.2 Instruments and equipment
The instrument for measuring length shall meet the following requirements: an optical system that produces parallel light;
—Imaging system: magnification 20 times. A standard template is available at the projection site. There should be a reference line and a length measurement baseline on the template to ensure that the length direction of the sample is parallel to the reference line and perpendicular to the length measurement baseline during projection. A workbench: It should have a V-groove for placing the sample and a baffle for positioning, which can realize the longitudinal and lateral movement of the sample and be equipped with a vernier ruler with an accuracy of 0.05mm.
A.3 Measurement steps
Adjust the sample according to GB/T16447 and test under corresponding environmental conditions. A.3.1 Turn on the power and adjust the instrument according to the instrument operating procedures. A.3.2 According to the specifications of the sample, select a standard rod of corresponding length and calibrate the standard length of the instrument. A.3.3 Place the sample in the V-groove of the workbench, with the overlap facing the operator and one end close to the positioning baffle. Move the workbench so that the length direction of the sample projection is parallel to the reference line, and the projection line of the other end of the sample coincides with the length measurement baseline, and read the length value of the sample from the vernier ruler. A.3.4 The reading should be based on the cut of the sample filter paper; if the cut of the sample end face is not even, the average of the maximum and minimum values should be taken. A.3.5 Repeat the steps of A.3.3 to A.3.4 and test a total of 30 samples.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Registration number: 10497—2002
Tobacco Industry Standard of the People's Republic of China
YC/T 37. 1 ---2002
Replaces YC/T37.1--1996
Test of filters physical characteristics--Part 1 :Length-Photoelectricity method2002-05-14 Issued
State Tobacco Monopoly Administration
Implementation on 2002-07-01
YC/T 37. 1--2002
This part is the first part of the YC/T37 "Determination of physical properties of filter rods" series of standards. This series of standards consists of seven parts: Determination of physical properties of filter rods Part 1: Length photoelectric method Part 2: Circumference Determination of physical properties of filter rods Laser method Determination of physical properties of filter rods Part 3: Absorption resistance Part 4: Hardness Determination of physical properties of filter rods Determination of physical properties of filter rods Part 5: Moisture Determination of physical properties of filter rods Part 6: Roundness Determination of physical properties of filter rods Part 7: Appearance This part replaces YC/T37.1-1996 "Determination of physical properties of filter rods Part 1: Length". The main changes of this part compared with YC/T37.1-1996 are as follows: Addition of the photoelectric method for determining the length of filter rods; Adjustment of YC/T 37.1-1996 to Appendix A. Appendix A of this part is an informative appendix.
This part was proposed by the State Tobacco Monopoly Administration. This part is under the jurisdiction of the National Tobacco Standardization Technical Committee (TC44). The drafting unit of this part is the National Tobacco Quality Supervision and Inspection Center. The main drafters of this part are Zhou Decheng, Li Xiaohui, Feng Xiaomin, Wang Yunfang and Zhao Hang. The previous versions of the standard replaced by this part are: YC/T37.1—1996. 548
1 Scope
Determination of physical properties of filter rods
Part 1: Length photoelectric methodwwW.bzxz.Net
This part of YC/T37 specifies the method for determining the length of filter rods. This part is applicable to various filter rods.
2 Normative references
YC/T 37. 1—2002
The clauses in the following documents become the clauses of this part through reference in this part of YC/T37. For dated references, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest versions apply to this part. GB/T16447 Atmospheric environment for conditioning and testing of tobacco and tobacco products (idtISO3402) 3 Principle of measurement
Use parallel light beams to project or scan the end of the filter rod to form a light signal, which is received by the photoelectric receiving device and processed by the data processing system to give the length value of the filter rod.
4 Instruments and equipment
4.1 Photoelectric length measuring instruments should meet the following requirements: automatic feeding;
Optical system that can generate parallel light beams (laser or ordinary light); capable of multi-point measurement of the end of the sample;
A photoelectric receiving device that can receive the signal at each measuring point; The data processing system can perform statistics on each measurement data and give the sample length value as the arithmetic mean; The accuracy of the instrument measurement result is 0.05mm. 4.2 Standard rod, accuracy is 0.005mm. 5 Measurement steps
Adjust the sample according to GB/T16447 and test under corresponding environmental conditions. 5.1 Turn on the power and adjust the instrument according to the instrument operating procedures. 5.2 According to the specifications of the sample, select a standard rod of corresponding length and calibrate the standard push length of the instrument. 5.3 Place the filter rod in the measuring position so that the parallel light beam shines on the end of the filter rod, and project or scan the end of the filter rod. 5.4 The filter rod length value is given by the photoelectric receiving device and the data processing system. 5.5 Repeat steps 5.3 to 5.4 and test a total of 30 samples. 6 Result expression
The measurement results are expressed in millimeters, accurate to 0.1 mm. 7 Measurement report
The measurement report shall include the following contents:
YC/T37.1—2002
The number of this part of YC/T37;
The mark and description of the sample;
The measurement time, the instrument and model used; the environmental conditions of the measurement and the measurement results.
A.1 Measurement principle
Appendix A
(Informative appendix)
Measurement of filter length by projection method
YC/T37.1—2002
Using the method of parallel light projection, the magnified image is compared with the "standard sample" to measure the length of the sample. A.2 Instruments and equipment
The instrument for measuring length shall meet the following requirements: an optical system that produces parallel light;
—Imaging system: magnification 20 times. A standard template is available at the projection site. There should be a reference line and a length measurement baseline on the template to ensure that the length direction of the sample is parallel to the reference line and perpendicular to the length measurement baseline during projection. A workbench: It should have a V-groove for placing the sample and a baffle for positioning, which can realize the longitudinal and lateral movement of the sample and be equipped with a vernier ruler with an accuracy of 0.05mm.
A.3 Measurement steps
Adjust the sample according to GB/T16447 and test under corresponding environmental conditions. A.3.1 Turn on the power and adjust the instrument according to the instrument operating procedures. A.3.2 According to the specifications of the sample, select a standard rod of corresponding length and calibrate the standard length of the instrument. A.3.3 Place the sample in the V-groove of the workbench, with the overlap facing the operator and one end close to the positioning baffle. Move the workbench so that the length direction of the sample projection is parallel to the reference line, and the projection line of the other end of the sample coincides with the length measurement baseline, and read the length value of the sample from the vernier ruler. A.3.4 The reading should be based on the cut of the sample filter paper; if the cut of the sample end face is not even, the average of the maximum and minimum values should be taken. A.3.5 Repeat the steps of A.3.3 to A.3.4 and test a total of 30 samples.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 6276-1992 Test methods for sugar beet harvesting machinery
- GB/T 23156-2010 Packaging—Packaging and the environment—Terminology
- JT/T 1286-2020 Manufacturing practice for transferred unitized cargo of air-ground intermodal transport
- HG/T 3585-1999 Liquid sodium borohydride
- GB 15976-1995 Standard for the control and elimination of schistosomiasis in my country
- GB/T 13400.2-1992 General rule for representation on network planning techniques
- QB/T 1582-1992 Terminology of leather hardware industry
- QB 1788-1993 Hediocarbaldehyde
- HG 2271.1-1992 S201 platinum catalyst for nitric acid production
- GB/T 14837-1993 Rubber and rubber products - Determination of component content - Thermogravimetric analysis
- GB/T 15131.1-1994 130 mm floppy disks with a bit density of 13262 flux reversals/radian and 80 tracks per side for information processing data exchange Part 1: Dimensions, physical properties and magnetic properties
- GB/T 2423.24-1995 Environmental testing for electric and electronic products Part 2: Test methods Test Sa: Simulated solar radiation on the ground
- HG/T 2303-1992 Industrial Acetanilide
- HG/T 2245-1991 Various colors of nitro pencil lacquers
- GB/T 15936.8-1995 Information processing text and office systems Office document architecture (ODA) and interchange formats Part 8: Geometric content architecture
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com