MT/T 412-1995 Flameproof low voltage terminal blocks for electrical equipment
time:
2025-03-18 23:33:58
- MT/T 412-1995
- in force
Standard ID:
MT/T 412-1995
Standard Name:
Flameproof low voltage terminal blocks for electrical equipment
Chinese Name:
隔爆型电气设备低压接线端子
Standard category:
Coal Industry Standard (MT)
-
Date of Release:
1995-12-05 -
Date of Implementation:
1996-03-01
China Standard Classification Number:
>>>>D9 Electrical>>Low Voltage Electrical Appliances>>K35 Explosion-proof Electrical Appliances
Drafter:
Yuan Yiping, Wang WenzhaoDrafting Organization:
China Coal Research Institute Shanghai BranchFocal point Organization:
Electrical Equipment Branch of Coal Mine Special Equipment Standardization Technical Committee of the Ministry of CoalProposing Organization:
Coal Mine Special Equipment Standardization Technical Committee of the Ministry of Coal IndustryPublishing Department:
Ministry of Coal Industry of the People's Republic of China
Skip to download
Summary:
This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of low-voltage wiring terminals for flameproof electrical equipment (hereinafter referred to as wiring terminals) made of Class A arc-resistant insulating materials. This standard applies to low-voltage wiring terminals for flameproof electrical equipment of Class dⅠ and dⅡB with rated voltage up to 1140V, rated current up to 630A and frequency up to 50Hz. This standard does not apply to wiring terminals for direct-in flameproof electrical equipment. MT/T 412-1995 Low-voltage wiring terminals for flameproof electrical equipment MT/T412-1995 Standard download decompression password: www.bzxz.net
Some standard content:
Coal Industry Standard of the People's Republic of China
Flameproof low-voltage terminal blocks for electrical equipment
1 Subject content and scope of application
MT/T412-1995
This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of flameproof low-voltage terminal blocks for electrical equipment (hereinafter referred to as terminal blocks) made of Class A arc-resistant insulating materials. This standard applies to dI and diB grade flameproof low-voltage terminal blocks for electrical equipment with rated voltage up to 1140V, rated current up to 630A and frequency up to 50Hz.
This standard does not apply to terminal blocks for direct-in flameproof electrical equipment. 2 Reference standards
GB1411
GB1497
Basic test methods for low-voltage electrical appliancesbzxz.net
High-voltage and low-current intermittent arc resistance test methods for solid electrical insulating materialsBasic standards for low-voltage electrical appliances
GB/T1804
General tolerancesUnmarked tolerances for linear dimensions
GB/T2423.4Basic environmental test procedures for electrical and electronic productsTest Db: Alternating damp heat test methodsGB3836.2
Explosion-proof electrical equipment for explosive atmospheresExplosion-proof electrical equipment "d"Explosion-proof electrical equipment for explosive atmospheresIncreased safety electrical equipment "e"GB4207 Solid insulating materials Determination method of tracking index and proof tracking index of materials under humid conditions JB834 Technical requirements for tropical low-voltage electrical appliances
JB4159
3 Product classification
General technical requirements for tropical electrical products
3.1 Single-core terminal blocks
3.1.1 Cylindrical mounting terminal blocks
3.1.1.1 Varieties and specifications
According to the rated insulation voltage U:, thread specifications of conductive rods and wire entry methods, there are 20 varieties, see Table 1\A" Table 1
Thread specifications of conductive rods
Wire entry methods
U:≤660
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Flameproof low-voltage terminal blocks for electrical equipment
1 Subject content and scope of application
MT/T412-1995
This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of flameproof low-voltage terminal blocks for electrical equipment (hereinafter referred to as terminal blocks) made of Class A arc-resistant insulating materials. This standard applies to dI and diB grade flameproof low-voltage terminal blocks for electrical equipment with rated voltage up to 1140V, rated current up to 630A and frequency up to 50Hz.
This standard does not apply to terminal blocks for direct-in flameproof electrical equipment. 2 Reference standards
GB1411
GB1497
Basic test methods for low-voltage electrical appliancesbzxz.net
High-voltage and low-current intermittent arc resistance test methods for solid electrical insulating materialsBasic standards for low-voltage electrical appliances
GB/T1804
General tolerancesUnmarked tolerances for linear dimensions
GB/T2423.4Basic environmental test procedures for electrical and electronic productsTest Db: Alternating damp heat test methodsGB3836.2
Explosion-proof electrical equipment for explosive atmospheresExplosion-proof electrical equipment "d"Explosion-proof electrical equipment for explosive atmospheresIncreased safety electrical equipment "e"GB4207 Solid insulating materials Determination method of tracking index and proof tracking index of materials under humid conditions JB834 Technical requirements for tropical low-voltage electrical appliances
JB4159
3 Product classification
General technical requirements for tropical electrical products
3.1 Single-core terminal blocks
3.1.1 Cylindrical mounting terminal blocks
3.1.1.1 Varieties and specifications
According to the rated insulation voltage U:, thread specifications of conductive rods and wire entry methods, there are 20 varieties, see Table 1\A" Table 1
Thread specifications of conductive rods
Wire entry methods
U:≤660
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 7369-1994 Mechanical seal end face flatness test method
- GB/T 11458.2-1989 Chinese character 15×16 dot matrix font data set for information processing, communication subset
- GB/T 3763-1983 Hexagonal thin nuts for ferrule type pipe fittings
- GB/T 15076.10-1994 Chemical analysis methods of tantalum and niobium - Determination of iron, nickel, chromium, titanium, zirconium, aluminium and manganese in niobium
- GB/T 5211.3-1985 Determination of volatile matter of pigments at 105°C
- HG/T 3689-2001 Test method for yellowing resistance of footwear
- GB/T 21048-2007 Star-rating standard for cinemas
- GB/T 21076-2007 Securities and related financial instruments—International securities identification numbering system
- GB 3102.12-1993 Characteristic number
- SL 290-2003 Design Specifications for Land Acquisition and Resettlement for Water Conservancy and Hydropower Project Construction (with Explanations)
- GB/T 4509-1998 Asphalt penetration test method
- JB/T 7683-1995 Classification and model compilation method of mechanical continuously variable transmission
- QB/T 2720-2005 皮革 化学试验 氧化铬(Cr2O3)的测定
- GB/T 3389.3-2001 Test methods for properties of piezoelectric ceramic materials - Test of Curie temperature Tc
- GB/T 40038-2021 Validation of vegetation index remote sensing products
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com