GB 3883.9-1991 Safety of hand-held power tools Part 2: Special requirements for electric tapping machines (available for certification)
time:
1991-05-27 16:00:00
- GB 3883.9-1991
- Abolished
Standard ID:
GB 3883.9-1991
Standard Name:
Safety of hand-held power tools Part 2: Special requirements for electric tapping machines (available for certification)
Chinese Name:
手持式电动工具的安全 第二部分:电动攻丝机的专用要求(可供认证用)
Standard category:
National Standard (GB)
-
Date of Release:
1991-05-27 -
Date of Implementation:
1992-02-01 -
Date of Expiration:
2005-08-01
Standard ICS number:
Machinery Manufacturing>>Hand Tools>>25.140.20 Power ToolsChina Standard Classification Number:
Electrician>>Electrical Equipment and Appliances>>K64 Power Tools
alternative situation:
GB 3883.9-1985; replaced by GB 3883.9-2005Procurement status:
IEC 745-2-9-1984 IDT
Review date:
2004-10-14Drafting Organization:
Shanghai Power Tools Research InstitutePublishing Department:
State Bureau of Technical Supervision
Skip to download
Summary:
GB 3883.9-1991 Safety of hand-held power tools Part 2: Special requirements for electric tapping machines (available for certification) GB3883.9-1991 Standard download and decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Safety of hand-held motor-operated electric tools
Part 2: Particular requirements for electric tappers( Available for certification)
GB3883.9-91
IEC745-2-9
replaces GB3883.9-85
This standard is equivalent to IEC745-2-9 "Safety of Handheld Power Tools Part 2: Special Requirements for Tapping Machines" 1984 first edition.
This standard should be used together with GB3883.1 "Safety of Handheld Power Tools Part 1 General Requirements". This standard lists the changes necessary to convert Part 1 into the "Safety Requirements for Tapping Machines" standard. 1 Scope of application
Except for the following provisions, this chapter of Part One applies: 1.1 is replaced with:
This standard applies to tapping machines.
2 Definitions
This chapter of Part One applies except for the following provisions: 2.2.23 Paragraph 1.
is replaced by:
Normal load refers to the load when the tool operates intermittently with 1 minute of continuous operation and 1 minute of power outage as one cycle. The load applied during continuous operation should have an input power (W) equal to the rated input power. Loads can be applied with brakes.
3 General requirements
This chapter of Part 1 applies.
4 General considerations for testing
This chapter of Part 1 applies.
5 Ratings
This chapter of Part One applies.
6 categories
This chapter of Part 1 applies.
State Bureau of Technical Supervision approved on 1991-05-27 for implementation on 1992-02-01
7 mark
GB3883.9—91
Except for the following provisions, Article Part of this chapter applies: 7.1 Addition:
In addition, the tool shall be marked with the following symbol:
The maximum diameter of the thread that can be cut, mm.
Note: Unless otherwise marked on the tool, this diameter should be understood to refer to the diameter of ISO metric threads cut in steel with a tensile strength of 390N/mm and a thickness of 2 times the thread diameter.
8 Protection against electric shock
This chapter of Part 1 applies.
9 Startup
This chapter of Part 1 applies.
10 Input power and current
Except for the following provisions, this chapter of Part One applies: 10.1 Modification:
This test will not be performed.
11 Fever
Except for the following provisions, this chapter of Part 1 applies: 11.4 Modification: www.bzxz.net
The tool operates at the specified normal load for 30 minutes. The temperature rise is measured at the end of the last run period. 12Leakage current
This chapter of Part 1 applies.
3 Radio and television interference suppression
This chapter of Part 1 applies.
14 Moisture resistance
This chapter of Part 1 applies.
15 Insulation resistance and dielectric strength
This chapter of Part 1 applies.
16 Durability
This chapter of Part One applies.
17 Abnormal Operation
This chapter of Part 1 applies.
Mechanical Hazards
This chapter of Part 1 applies.
19 Mechanical Strength
This chapter of Part 1 applies.
20 Structure
This chapter of Part 1 applies.
21 Internal Wiring
This chapter of Part 1 applies.
22 components
This chapter from Part 1 applies.
23 Power connection and external flexible cables and cords This chapter of Part 1 applies.
24 Terminal blocks for external conductors
This chapter of Part 1 applies.
25 Ground Protection
This chapter of Part 1 applies.
26 Screws and Connections
This chapter of Part 1 applies.
27 Creepage distances, electrical clearances and insulation penetration distances This chapter of Part 1 applies.
28 Heat resistance, flame resistance and resistance to leakage and tracking. This chapter of Part 1 applies.
29 Rust Prevention
This chapter of Part 1 applies.
GB3883.9—91
This appendix to Part 1 applies.
This addendum to Part 1 applies.
This addendum to Part 1 applies.
This addendum to Part 1 applies.
Additional instructions:
GB3883.9—91
Appendix A
Thermal circuit breaker and overload release
(supplement)||tt ||Appendix B
Electronic circuit
(Supplement)
Appendix C
Structure of safety isolation transformer
(Supplement)||tt| |Appendix D
Measurement of creepage distances and clearances
(Supplement)
This standard is proposed by the Ministry of Mechanical and Electronics Industry of the People's Republic of China. This standard is under the jurisdiction of the National Technical Committee for Standardization of Power Tools. This standard is drafted by the Shanghai Power Tool Research Institute of the Ministry of Mechanical and Electronic Industry. The main drafters of this standard are Li Hongzhao and Qian Naichi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Safety of hand-held motor-operated electric tools
Part 2: Particular requirements for electric tappers( Available for certification)
GB3883.9-91
IEC745-2-9
replaces GB3883.9-85
This standard is equivalent to IEC745-2-9 "Safety of Handheld Power Tools Part 2: Special Requirements for Tapping Machines" 1984 first edition.
This standard should be used together with GB3883.1 "Safety of Handheld Power Tools Part 1 General Requirements". This standard lists the changes necessary to convert Part 1 into the "Safety Requirements for Tapping Machines" standard. 1 Scope of application
Except for the following provisions, this chapter of Part One applies: 1.1 is replaced with:
This standard applies to tapping machines.
2 Definitions
This chapter of Part One applies except for the following provisions: 2.2.23 Paragraph 1.
is replaced by:
Normal load refers to the load when the tool operates intermittently with 1 minute of continuous operation and 1 minute of power outage as one cycle. The load applied during continuous operation should have an input power (W) equal to the rated input power. Loads can be applied with brakes.
3 General requirements
This chapter of Part 1 applies.
4 General considerations for testing
This chapter of Part 1 applies.
5 Ratings
This chapter of Part One applies.
6 categories
This chapter of Part 1 applies.
State Bureau of Technical Supervision approved on 1991-05-27 for implementation on 1992-02-01
7 mark
GB3883.9—91
Except for the following provisions, Article Part of this chapter applies: 7.1 Addition:
In addition, the tool shall be marked with the following symbol:
The maximum diameter of the thread that can be cut, mm.
Note: Unless otherwise marked on the tool, this diameter should be understood to refer to the diameter of ISO metric threads cut in steel with a tensile strength of 390N/mm and a thickness of 2 times the thread diameter.
8 Protection against electric shock
This chapter of Part 1 applies.
9 Startup
This chapter of Part 1 applies.
10 Input power and current
Except for the following provisions, this chapter of Part One applies: 10.1 Modification:
This test will not be performed.
11 Fever
Except for the following provisions, this chapter of Part 1 applies: 11.4 Modification: www.bzxz.net
The tool operates at the specified normal load for 30 minutes. The temperature rise is measured at the end of the last run period. 12Leakage current
This chapter of Part 1 applies.
3 Radio and television interference suppression
This chapter of Part 1 applies.
14 Moisture resistance
This chapter of Part 1 applies.
15 Insulation resistance and dielectric strength
This chapter of Part 1 applies.
16 Durability
This chapter of Part One applies.
17 Abnormal Operation
This chapter of Part 1 applies.
Mechanical Hazards
This chapter of Part 1 applies.
19 Mechanical Strength
This chapter of Part 1 applies.
20 Structure
This chapter of Part 1 applies.
21 Internal Wiring
This chapter of Part 1 applies.
22 components
This chapter from Part 1 applies.
23 Power connection and external flexible cables and cords This chapter of Part 1 applies.
24 Terminal blocks for external conductors
This chapter of Part 1 applies.
25 Ground Protection
This chapter of Part 1 applies.
26 Screws and Connections
This chapter of Part 1 applies.
27 Creepage distances, electrical clearances and insulation penetration distances This chapter of Part 1 applies.
28 Heat resistance, flame resistance and resistance to leakage and tracking. This chapter of Part 1 applies.
29 Rust Prevention
This chapter of Part 1 applies.
GB3883.9—91
This appendix to Part 1 applies.
This addendum to Part 1 applies.
This addendum to Part 1 applies.
This addendum to Part 1 applies.
Additional instructions:
GB3883.9—91
Appendix A
Thermal circuit breaker and overload release
(supplement)||tt ||Appendix B
Electronic circuit
(Supplement)
Appendix C
Structure of safety isolation transformer
(Supplement)||tt| |Appendix D
Measurement of creepage distances and clearances
(Supplement)
This standard is proposed by the Ministry of Mechanical and Electronics Industry of the People's Republic of China. This standard is under the jurisdiction of the National Technical Committee for Standardization of Power Tools. This standard is drafted by the Shanghai Power Tool Research Institute of the Ministry of Mechanical and Electronic Industry. The main drafters of this standard are Li Hongzhao and Qian Naichi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 20601-2006 Safety rules for classification、precautionary labelling andprecautionary statements of chemicals - Specific target organ systemic toxicity - Repeated exposure
- JB/T 5834.1-1991 Power rectifier module MDC, MDA and MDK series rectifier bridge arm module above 25A
- GBZ 62-2002 Diagnostic criteria for occupational skin ulcers
- JB/T 7048-2002 Technical requirements for engineering plastic cages of rolling bearing parts
- JB/T 10214-2000 Technical requirements for rivet welded parts of ventilators
- GB/T 8454-1987 Determination of ferrous iron content in reduced ilmenite powder for welding electrodes
- GB/T 40292-2021 Cross-border electronic commerce—Specification for electronic waybill
- DZ/T 0173-1997 Technical specification for magnetotelluric sounding method
- HG 20503-1992 Noise Control Design Regulations for Chemical Construction Projects
- GB/T 4074.1-1999 Winding wire test methods Part 1: General provisions
- GB/T 21649.2-2017 Particle size analysis—Image analysis methods—Part 2:Dynamic image analysis methods
- JB/T 1666-1997 Crawler bulldozer test methods
- SJ 20740-1999 Battlefield reconnaissance radar performance test method
- GB 4909.11-1985 Test methods for bare wires - Coating adhesion test
- JB/T 8791-1998 Spring-loaded internal diameter dial indicator
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com