GB 5013.6-1997 Rubber insulated cables with rated voltages up to and including 450/750V Part 6: Welding machine cables

time: 2024-08-04 11:56:12
  • GB 5013.6-1997
  • Abolished

Basic Information

standard classification number

  • Standard ICS number:

    Electrical engineering>>Wires and cables>>29.060.20 Cables
  • China Standard Classification Number:

    Electrical Engineering>>Electrical Materials and General Parts>>K13 Cables and Accessories

associated standards

Publication information

  • publishing house:

    China Standards Press

Other Information

  • Release date:

    1985-03-23
  • Review date:

    2004-10-14
  • Drafting Organization:

    Shanghai Cable Research Institute, Ministry of Machinery Industry
  • Focal point Organization:

    National Wire and Cable Standardization Technical Committee
  • Publishing Department:

    State Bureau of Technical Supervision
  • Competent Authority:

    China Electrical Equipment Industry Association
Introduction to standardsDescription (Translated English) / download

Skip to download

Summary:

This part details the technical requirements for rubber insulated welding machine cables. Each cable should meet the corresponding requirements specified in GB 5013.1 and the special requirements of this part. GB 5013.6-1997 Rubber insulated cables with rated voltages up to and including 450/750V Part 6: Welding machine cables GB5013.6-1997 Standard download decompression password: www.bzxz.net
Standard contentStandard content

Some standard content:

National Standard of the People's Republic of China
Kubber insulated cables of ratedvoltages up to and including 450/750 vPart 6:Arc welding cables
1 Overview
1.1 Scope
GB5013 Part 6 details the technical requirements for rubber insulated arc welding cables. Each cable shall comply with the corresponding requirements specified in GB5013.1 and the special requirements of this part. 1.2 Referenced standards
GB 5013 6—1997
idt 1EC 245-6:1994
Replaces GB5013.385
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. The versions shown are valid at the time of publication of this standard. All standards are subject to revision. Parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T2951.1-1997 General test methods for cable insulation and sheathing materials Part 1: Test methods Section 1: Thickness and dimensions measurement - Mechanical properties test (GB/T2951.2-1997 General test methods for cable insulation and sheathing materials Part 1: General test methods Section 2: Thermal aging test methods bZxz.net
GB/T2951.5-1997 General test methods for cable insulation and sheathing materials Part 2: Special test methods for elastomer mixtures Section 1: Section, ozone resistance test - thermal extension test - mineral oil test GB5013.1-1997 Lemon-skin insulated cables with rated voltages up to and including 450/750V Part 1: General requirements GB5013.2-1997 Lemon-skin insulated cables with rated voltages up to and including 450/750V Part 2: Test methods 2 Electric welding machine cables
2.1 Model
Rubber sheathed electric welding machine cables: 245IEC81 (YH); Fluorinated rubber or other equivalent synthetic elastomer rubber sheathed electric coal machine cables: 245IEC82 (YHF) 2.2 Rated voltage
Because this type of core cable is designed for welding, the rated voltage is not specified. 2.3 Structure
2.3.1 Conductor
Number of cores: I core.
The conductor shall meet the requirements of column 2 of Table 1. Single wires may be untinned or tinned. 2.3.2 Isolation layer
An isolation layer made of suitable material shall be added around the conductor. 2.3.3 Insulation layer
Approved by the State Administration of Technical Supervision on October 13, 1997 and implemented on October 1, 1998
GB 5013.6—1997
The conductor and the isolation layer shall be protected by one of the following. 2.3.3.1 A covering layer of SE3 rubber mixture with a minimum tensile strength of 12 MPa shall constitute the insulation and sheath. Its thickness shall comply with the values ​​specified in column 3 of Table 1.
2.3.3.2 A covering layer of SE4 chloroprene or other equivalent synthetic elastomer mixture shall constitute the insulation and sheath. Its thickness shall comply with the values ​​specified in column 3 of Table 1.
2.3.3.3 A covering layer of IE1 rubber mixture with a minimum tensile strength of 12 MPa shall constitute the insulation and sheath. Its thickness shall comply with the values ​​specified in column 3 of Table 1. Composite covering consisting of material insulation, one optional fabric tape and one SE4 type chloroprene or other equivalent synthetic elastomer compound sheath, the total thickness shall comply with the values ​​specified in column 3 of Table 1, and the thickness of the expanded sheath in the composite covering shall comply with the values ​​specified in column 4 of Table 1; if the insulation is not extruded, it shall consist of at least two layers. 2.3.4 External diameter
The average external diameter shall be within the upper and lower limits specified in columns 5 and 6 of Table 1. 2.4 Tests
The tests and tests specified in Table 2 shall be used to check whether the requirements of 2.3 are met. 2.5 Guidelines for use
Under consideration.
Table 1 245IEC81 (YH) and 245IEC82 (YHF) type cables
Nominal cross-section of conductor
Single wire in conductor
Maximum diameter of single wire
Total floor of the cable
1) The insulation thickness of the composite covering is not measured separately.
Specified value of sheath thickness in composite covering layer
Average outer diameter
21 C: Conductor resistance
Galvanized single wire
Table 2245TEC81 (YH) and 245TEC82 (YHF) type cable test number
Test item
Electrical performance test
Conductor resistance
100V voltage test for finished cable
Structural dimension inspection
Structural inspection
Micro-covering layer thickness measurement
Outer diameter measurement
Insulation mechanical properties\
Tensile test before aging
Tensile test after air oven aging
Tensile test after hydrogen bomb aging
Test type
Test method
GB(GB/T)
5013.15013.2
Unplated single wire
Document number
Inspection and manual test
Test purpose
Heat extension test
Sheath mechanical properties of sheath or composite covering
Tensile test before aging
Tensile test after aging in air oven
Tensile test after aging"
Tear test
Heat extension test
Mechanical strength of finished cable
Static flexure test
GB 5013.6—1997
Table 2 (end)
Test type
Test method
GB(GE/T)
Under examination
1) Only applicable to cables with a composite covering layer having a type 1 sheath compound as a separate insulating layer. 2) Only applicable to 245IEC82(YHF) type cables. Article number
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]