GB/T 11606.14-1989 Environmental test methods for analytical instruments - Low temperature storage test
time:
2024-08-06 10:58:15
- GB/T 11606.14-1989
- Abolished
Standard ID:
GB/T 11606.14-1989
Standard Name:
Environmental test methods for analytical instruments - Low temperature storage test
Chinese Name:
分析仪器环境试验方法 低温贮存试验
Standard category:
National Standard (GB)
-
Date of Release:
1989-03-31 -
Date of Implementation:
1990-03-01 -
Date of Expiration:
2007-12-01
Standard ICS number:
Test >> 19.040 Environmental TestChina Standard Classification Number:
Instruments and meters>>Material composition analysis instruments and environmental monitoring instruments>>N50 Material composition analysis instruments and environmental monitoring instruments comprehensive
alternative situation:
Replaced by GB/T 11606-2007
Review date:
2004-10-14Drafting Organization:
Beijing Analytical Instruments InstituteFocal point Organization:
National Technical Committee for Industrial Process Measurement and Control StandardizationPublishing Department:
China Machinery Industry FederationCompetent Authority:
China Machinery Industry Federation
Skip to download
Summary:
GB/T 11606.14-1989 Environmental test methods for analytical instruments Low temperature storage test GB/T11606.14-1989 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Environmental test method for analytical instruments
Cold storage test
The method of cnvironmental test for analytical instrumentscntsCold storage test
1 Subject content and scope of application
GB11606.14-89
This standard specifies the grouping, test conditions and test methods of low temperature storage test for analytical instruments (hereinafter referred to as instruments). This standard is applicable to the assessment of the adaptability of fully packaged instruments for transportation and storage under low temperature environmental conditions. 2 Low temperature storage test grouping
3. Test conditions
3.1 Requirements for test equipment
3.1.1 The test box (room) should be able to provide the temperature specified in Chapter 2 of this standard in its working space, with an allowable error of ±2°C. The instrument should not be directly radiated by any heating and cooling elements. 3.1.2 The volume of the test box (room) should be greater than 3 times the volume of the instrument. 4 Test method
4.1 Pretreatment
Put the instrument in normal (or reference) environmental conditions to achieve temperature equilibrium. 4.2 Test
Put the instrument in the test box (room), then lower the temperature of the test box (room) to the specified value at an average temperature change rate of less than 1℃/min, and keep it for 8h.
4.3 Recovery
After the test, the instrument remains in the test box (room), and the temperature of the test box (room) is raised to normal (or reference) environmental conditions at an average temperature change rate of less than 1℃/min, and the recovery time is 8h. 4.4 Final inspection
Inspect the instrument according to relevant standards. www.bzxz.net
GB/T11606.14—1989 "Analytical Instrument Environmental Test Method Low Temperature Storage Test" Amendment No. 1 This amendment was approved by the State Administration of Quality and Technical Supervision on July 19, 2000 in the document No. [2000]108, and will be effective from December 1, 2000. 1. Add one more article between the original Articles 4.1 and 4.2, and it is numbered as Article 4.2. 4.2 Initial Inspection
Inspect the instrument according to the relevant standards. 2. The original Article 4.2 and the following articles are modified accordingly.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Environmental test method for analytical instruments
Cold storage test
The method of cnvironmental test for analytical instrumentscntsCold storage test
1 Subject content and scope of application
GB11606.14-89
This standard specifies the grouping, test conditions and test methods of low temperature storage test for analytical instruments (hereinafter referred to as instruments). This standard is applicable to the assessment of the adaptability of fully packaged instruments for transportation and storage under low temperature environmental conditions. 2 Low temperature storage test grouping
3. Test conditions
3.1 Requirements for test equipment
3.1.1 The test box (room) should be able to provide the temperature specified in Chapter 2 of this standard in its working space, with an allowable error of ±2°C. The instrument should not be directly radiated by any heating and cooling elements. 3.1.2 The volume of the test box (room) should be greater than 3 times the volume of the instrument. 4 Test method
4.1 Pretreatment
Put the instrument in normal (or reference) environmental conditions to achieve temperature equilibrium. 4.2 Test
Put the instrument in the test box (room), then lower the temperature of the test box (room) to the specified value at an average temperature change rate of less than 1℃/min, and keep it for 8h.
4.3 Recovery
After the test, the instrument remains in the test box (room), and the temperature of the test box (room) is raised to normal (or reference) environmental conditions at an average temperature change rate of less than 1℃/min, and the recovery time is 8h. 4.4 Final inspection
Inspect the instrument according to relevant standards. www.bzxz.net
GB/T11606.14—1989 "Analytical Instrument Environmental Test Method Low Temperature Storage Test" Amendment No. 1 This amendment was approved by the State Administration of Quality and Technical Supervision on July 19, 2000 in the document No. [2000]108, and will be effective from December 1, 2000. 1. Add one more article between the original Articles 4.1 and 4.2, and it is numbered as Article 4.2. 4.2 Initial Inspection
Inspect the instrument according to the relevant standards. 2. The original Article 4.2 and the following articles are modified accordingly.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 15249.3-1994 Chemical analysis methods for alloy gold - Iodometric method for determination of copper content
- JB/T 4751-2003 Spiral plate heat exchanger
- GB/T 16173-1996 Determination of smoke emission from combustion or pyrolysis of building materials (double chamber method)
- JB/T 1827.1-1999 Technical requirements for air hammers
- GB/T 3414-1994 Hot-rolled special-shaped steel for coal mining machinery
- GB/T 9121.1-2000 Raised face flat welded ring plate loose sleeve steel pipe flange
- SY/T 0047-1999 Technical specification for internal cathodic protection system of crude oil processing vessels
- JB/T 6991-1993 Peripheral transmission concentrator
- GB/T 5009.129-2003 Determination of ethoxyquin residues in fruits
- GB 2961-1990 Aniline
- GB/T 18730-2002 Document imaging applications--Microfilming of achromatic maps on 35mm microfilm
- JB/T 5446-1999 Piston type single unit two-stage refrigeration compressor
- DA/T 7-1992 Inline file racks
- GB/T 38171-2019 Metal chelating chromatographic medium
- GB/T 9123.1-2000 Flat and raised face steel pipe flange covers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com