JG/T 5061.1-1995 thick wall soil extractor
time:
2024-08-07 05:36:40
- JG/T 5061.1-1995
- in force
Standard ID:
JG/T 5061.1-1995
Standard Name:
thick wall soil extractor
Chinese Name:
厚壁取土器
Standard category:
Construction industry industry standards (JG)
-
Date of Release:
1996-01-05 -
Date of Implementation:
1996-06-01
Standard ICS number:
Building materials and buildings >> 91.220 Construction equipmentChina Standard Classification Number:
Engineering Construction>>Construction Machinery and Equipment>>P97 Construction Machinery for Building Engineering
Drafter:
Zhang Wenxiu, Cui Jianmin, Qiao GuifangDrafting Organization:
Ministry of Construction Comprehensive Survey and Research Institute, China North Survey and Research Institute of Ordnance IndustryFocal point Organization:
Beijing Construction Machinery Research Institute, the responsible unit for mechanical equipment and vehicle standards and technologies under the Ministry of ConstructionProposing Organization:
Standard and Quota Research Institute of the Ministry of ConstructionPublishing Department:
Ministry of Construction of the People's Republic of China

Skip to download
Summary:
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of thick-walled soil samplers. This standard applies to soil samplers for sampling soft plastic, plastic, hard plastic, hard clay, silt and silt sand secondary quality undisturbed soil samples in boreholes as specified in GB 50021 and JGJ 89. JG/T 5061.1-1995 Thick-walled soil sampler JG/T5061.1-1995 Standard download decompression password: www.bzxz.net

Some standard content:
Engineering Construction Standard Full-text Information System
Construction Industry Standard of the People's Republic of China JG/T5061.1-1995
Thick wall sampler
Thickwallsampler
Published on January 5, 1996
Implementation on June 1, 1996
Ministry of Construction of the People's Republic of China
bzsoso.co Engineering Construction Standard Full-text Information System
Construction Industry Standard of the People's Republic of China Thick wall sampler
Subject Content and Scope of Application
JG/T5061.1-1995
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of thick wall samplers.
This standard applies to the soil samplers specified in GB50021 and JGJ89 for taking soft plastic, plastic, hard plastic, hard clay, and silt and silt sand secondary quality undisturbed soil samples in boreholes. 2 Reference standards
GB197 General thread tolerances and fits (diameter 1 ~ 355mm)GB50021 Geotechnical engineering investigation specification
JGJ89 Undisturbed soil sampling technical standards
YB235 Geological drilling steel pipe
DZ25 Geological drilling drill rod lock joint
JG/T5012
General technical conditions for packaging of construction machinery and equipment3
Product classification
Main parameters and size series
Heavy wall sampling takes the outer diameter of the main sampler as the main parameter, and the series are as follows: 89mm; 108mm.
3.2 Structure
See Figure 1.
1—variable thread joint, 2—piston 3—lift cap; 4—gasket, 5—rubber gasket, 6—lower gasket, 7—nut; 8—waste pipe; 9—liner; 10—sampling pipe 3.3 Model
Approved by the Ministry of Construction of the People's Republic of China on 1996-01-05 and implemented on 1996-06-01
Engineering Construction Standard Full Text Information System
The model of thick-walled soil sampler consists of type code and main parameters. 3.3.1 Model compilation method
3.$.2 Marking example
Thick-walled soil sampler with an outer diameter of 108mm:
108JG/T5061.1
Soil sampler TH
3.4 Basic parameters
The basic parameters should comply with the provisions of Table 1.
Area ratio, %
Internal clearance ratio, %
External clearance ratio, %
Area ratio (A), calculated according to formula (1).
Where: Dw
Update, variant code, expressed in the order of Chinese Pinyin
letters (uppercase print)
Main parameters: soil sampler outer diameter, mm
Soil sampler
Blade angle, (°)
Soil sampler outer diameter (sampling tube shoe outer diameter), mm - soil sampler blade inner diameter, mm.
Internal clearance ratio (Ci), calculated according to formula (2). 3.4.2
Inner diameter of liner, mm.
Where: Ds
3.4.3 External clearance ratio (Co), calculated according to formula (3). Dw-Dt
tx100%
Where: Dt
-Outer diameter of sampling tube, mm.
Technical requirements
Products shall be manufactured according to drawings and technical documents approved by prescribed procedures. Main parameters and basic parameters shall comply with the provisions of 3.1 and 3.4. 4.2
Liner length, mm
150,200,300
Waste soil pipe length, mm
4.3The sampling tube shall be made of seamless steel pipe with mechanical properties not lower than DZ50, and the quenching hardness of the cutting edge shall be HRC42~46. Its dimensional deviation shall comply with the provisions of Table 2.
bzsos, gong mm
Engineering Construction Standard Full Text Information System
Inner diameter of cutting edge
Straightness
The sampling tube has no obvious extrusion, concave-convex, flat round and other defects. Table 2
The special trapezoidal threads of the sampling tube, waste soil tube and lifting cap shall comply with the provisions of the threads of geological core tubes, casing and their joints in YB235. The tolerances and technical requirements of ordinary threads and locking joints shall be implemented in accordance with GB197 and DZ25 respectively. The surface of all processed parts of the soil sampler shall be treated with anti-rust, such as bluing or blackening, and the color shall be uniform. The cross-sectional area of the drainage channel of the soil sampler head shall not be less than 7.5% of the inner diameter of the cutting edge, and the internal mud and water discharge shall be unobstructed. Test method
Place the sampling tube on a 1.2m×1.0m flat plate not less than the third level, and check its straightness by conventional methods, which shall comply with the provisions of Table 2. Special trapezoidal threads, locking joint threads and ordinary threads are inspected with standard thread test gauges. The inner diameter, outer diameter and wall thickness of the sampling tube are measured with a vernier caliper, and the deviation shall comply with the provisions of Table 2. Inspection rules
Thick-walled soil samplers are divided into type inspection and factory inspection. 6.1 Type inspection is a comprehensive inspection of its performance, parameters, etc. Type inspection includes 4.1 to 4.8 of this standard. Type inspection should be carried out when one of the following situations occurs.
Trial production and identification of new products or old products transferred to the factory for production After formal production, when there are major changes in structure, materials and processes that may affect product performance; c
When the national quality inspection and supervision agency proposes a type inspection requirement. The sampled samplers must pass the type inspection only if all the inspection items specified in this standard are qualified. During formal production, random inspection is carried out after a certain number of products have accumulated, and the number of random inspections is 2%. If there are less than 100 pieces, no less than two pieces. When there are unqualified products, double sampling shall be conducted; if there are still unqualified products, each product must be inspected. 6.2 Factory inspection is the inspection of the main parameters of the soil sampler, special trapezoidal thread connection, sampling tube size and blade angle. The product is allowed to leave the factory after passing the inspection
Marking, packaging, transportation, storage
The product name, model, specification and manufacturer's logo should be on the obvious part of the product. 7.2 Packaging
The packaging shall be carried out in accordance with JG/T5012.
7.3 Transportation
During transportation, the product should be placed in the packaging box and shall not be transported exposed. Measures such as moisture-proof, collision-proof and extrusion-proof should be taken. It shall not be shipped together with acidic and alkaline items. www.bzxz.net
7.4 Storage
The product should be placed in a dry and ventilated warehouse and shall not be mixed with acidic and alkaline items. Engineering Construction Standard Full Text Information System
Additional Notes:
This standard was proposed by the Standard and Quota Research Institute of the Ministry of Construction. This standard is managed by the Beijing Construction Machinery Comprehensive Research Institute, the Ministry of Construction's machinery equipment and vehicle standard technology management unit. This standard was drafted by the Ministry of Construction's Comprehensive Survey and Research Institute and China North Industries Group Corporation's ...
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Construction Industry Standard of the People's Republic of China JG/T5061.1-1995
Thick wall sampler
Thickwallsampler
Published on January 5, 1996
Implementation on June 1, 1996
Ministry of Construction of the People's Republic of China
bzsoso.co Engineering Construction Standard Full-text Information System
Construction Industry Standard of the People's Republic of China Thick wall sampler
Subject Content and Scope of Application
JG/T5061.1-1995
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of thick wall samplers.
This standard applies to the soil samplers specified in GB50021 and JGJ89 for taking soft plastic, plastic, hard plastic, hard clay, and silt and silt sand secondary quality undisturbed soil samples in boreholes. 2 Reference standards
GB197 General thread tolerances and fits (diameter 1 ~ 355mm)GB50021 Geotechnical engineering investigation specification
JGJ89 Undisturbed soil sampling technical standards
YB235 Geological drilling steel pipe
DZ25 Geological drilling drill rod lock joint
JG/T5012
General technical conditions for packaging of construction machinery and equipment3
Product classification
Main parameters and size series
Heavy wall sampling takes the outer diameter of the main sampler as the main parameter, and the series are as follows: 89mm; 108mm.
3.2 Structure
See Figure 1.
1—variable thread joint, 2—piston 3—lift cap; 4—gasket, 5—rubber gasket, 6—lower gasket, 7—nut; 8—waste pipe; 9—liner; 10—sampling pipe 3.3 Model
Approved by the Ministry of Construction of the People's Republic of China on 1996-01-05 and implemented on 1996-06-01
Engineering Construction Standard Full Text Information System
The model of thick-walled soil sampler consists of type code and main parameters. 3.3.1 Model compilation method
3.$.2 Marking example
Thick-walled soil sampler with an outer diameter of 108mm:
108JG/T5061.1
Soil sampler TH
3.4 Basic parameters
The basic parameters should comply with the provisions of Table 1.
Area ratio, %
Internal clearance ratio, %
External clearance ratio, %
Area ratio (A), calculated according to formula (1).
Where: Dw
Update, variant code, expressed in the order of Chinese Pinyin
letters (uppercase print)
Main parameters: soil sampler outer diameter, mm
Soil sampler
Blade angle, (°)
Soil sampler outer diameter (sampling tube shoe outer diameter), mm - soil sampler blade inner diameter, mm.
Internal clearance ratio (Ci), calculated according to formula (2). 3.4.2
Inner diameter of liner, mm.
Where: Ds
3.4.3 External clearance ratio (Co), calculated according to formula (3). Dw-Dt
tx100%
Where: Dt
-Outer diameter of sampling tube, mm.
Technical requirements
Products shall be manufactured according to drawings and technical documents approved by prescribed procedures. Main parameters and basic parameters shall comply with the provisions of 3.1 and 3.4. 4.2
Liner length, mm
150,200,300
Waste soil pipe length, mm
4.3The sampling tube shall be made of seamless steel pipe with mechanical properties not lower than DZ50, and the quenching hardness of the cutting edge shall be HRC42~46. Its dimensional deviation shall comply with the provisions of Table 2.
bzsos, gong mm
Engineering Construction Standard Full Text Information System
Inner diameter of cutting edge
Straightness
The sampling tube has no obvious extrusion, concave-convex, flat round and other defects. Table 2
The special trapezoidal threads of the sampling tube, waste soil tube and lifting cap shall comply with the provisions of the threads of geological core tubes, casing and their joints in YB235. The tolerances and technical requirements of ordinary threads and locking joints shall be implemented in accordance with GB197 and DZ25 respectively. The surface of all processed parts of the soil sampler shall be treated with anti-rust, such as bluing or blackening, and the color shall be uniform. The cross-sectional area of the drainage channel of the soil sampler head shall not be less than 7.5% of the inner diameter of the cutting edge, and the internal mud and water discharge shall be unobstructed. Test method
Place the sampling tube on a 1.2m×1.0m flat plate not less than the third level, and check its straightness by conventional methods, which shall comply with the provisions of Table 2. Special trapezoidal threads, locking joint threads and ordinary threads are inspected with standard thread test gauges. The inner diameter, outer diameter and wall thickness of the sampling tube are measured with a vernier caliper, and the deviation shall comply with the provisions of Table 2. Inspection rules
Thick-walled soil samplers are divided into type inspection and factory inspection. 6.1 Type inspection is a comprehensive inspection of its performance, parameters, etc. Type inspection includes 4.1 to 4.8 of this standard. Type inspection should be carried out when one of the following situations occurs.
Trial production and identification of new products or old products transferred to the factory for production After formal production, when there are major changes in structure, materials and processes that may affect product performance; c
When the national quality inspection and supervision agency proposes a type inspection requirement. The sampled samplers must pass the type inspection only if all the inspection items specified in this standard are qualified. During formal production, random inspection is carried out after a certain number of products have accumulated, and the number of random inspections is 2%. If there are less than 100 pieces, no less than two pieces. When there are unqualified products, double sampling shall be conducted; if there are still unqualified products, each product must be inspected. 6.2 Factory inspection is the inspection of the main parameters of the soil sampler, special trapezoidal thread connection, sampling tube size and blade angle. The product is allowed to leave the factory after passing the inspection
Marking, packaging, transportation, storage
The product name, model, specification and manufacturer's logo should be on the obvious part of the product. 7.2 Packaging
The packaging shall be carried out in accordance with JG/T5012.
7.3 Transportation
During transportation, the product should be placed in the packaging box and shall not be transported exposed. Measures such as moisture-proof, collision-proof and extrusion-proof should be taken. It shall not be shipped together with acidic and alkaline items. www.bzxz.net
7.4 Storage
The product should be placed in a dry and ventilated warehouse and shall not be mixed with acidic and alkaline items. Engineering Construction Standard Full Text Information System
Additional Notes:
This standard was proposed by the Standard and Quota Research Institute of the Ministry of Construction. This standard is managed by the Beijing Construction Machinery Comprehensive Research Institute, the Ministry of Construction's machinery equipment and vehicle standard technology management unit. This standard was drafted by the Ministry of Construction's Comprehensive Survey and Research Institute and China North Industries Group Corporation's ...
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2569.3-2002 钢锉 整形锉
- JB 5317.3-1991 Conical rotor motor for electric chain hoist
- BB/T 0080-2019 Wooden collar box
- QB 1797-1993 Osmanthus extract
- GB/T 17139-1997 Soil quality-Determination of nickel-Flame atomic absorption spectrophotometry
- QB/T 2660-2004 Lotion
- JB/T 8045.4-1999 Bushings for machine tool fixture parts and components
- NY/T 2607-2014 Cultivation of higher aquatic plants
- GB/T 9222-1988 Strength calculation of pressure components of water tube boilers
- JB/T 7363-1994 Technical conditions for carbonitriding heat treatment of rolling bearing parts
- JB/T 7302-1994 Packaging of rock drilling machinery and pneumatic tools
- JB/T 7887-1996 KY series rotary drill
- GB/T 5009.157-2003 Determination of organic acids in food
- GB 30000.16-2013 Rules for classification and labelling of chemicals—Part 16:Organic peroxides
- JB/T 9193-1999 Diameter of blank before rolling ordinary thread
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]