
GB/T 3953-1983 Electrical round copper wire
time:
2024-08-10 16:52:35
- GB/T 3953-1983
- in force
Standard ID:
GB/T 3953-1983
Standard Name:
Electrical round copper wire
Chinese Name:
电工圆铜线
Standard category:
National Standard (GB)
-
Date of Release:
1983-01-01 -
Date of Implementation:
1984-10-01
Standard ICS number:
Electrical engineering>>Wires and cables>>29.060.10 WiresChina Standard Classification Number:
Electrical Engineering>>Electrical Materials and General Parts>>K11 Bare Wire
alternative situation:
Replaced JB 647-1977; replaced by GB/T 3953-2009Procurement status:
≈IEC 28
Release date:
1983-11-26Review date:
2004-10-14Drafter:
Deng MuxiangDrafting Organization:
Shanghai Cable Research Institute of the Ministry of Machinery Industry, etc.Focal point Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryProposing Organization:
Ministry of Machinery and Civil Engineering of the People's Republic of ChinaPublishing Department:
China Electrical Equipment Industry AssociationCompetent Authority:
China Electrical Equipment Industry Association

Skip to download
Summary:
The provisions of this standard are consistent with those of the International Electrotechnical Commission (IEC) 28. This standard applies to the manufacture of round copper wires for wires and cables and motors and electrical appliances. GB/T 3953-1983 Electrical round copper wire GB/T3953-1983 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Electrical Round Copper Wire
Round copper wirefor electrical purposes The provisions of this standard are in accordance with the provisions of the International Electrotechnical Commission (IEC) 28. Scope of application
This standard applies to round copper wires used in the manufacture of wires and cables and motors and electrical appliances. 2 Model
The round copper wire models are shown in Table 1.
3 Specifications
The specifications of round copper wires are expressed in nominal diameters, and their specifications shall comply with the provisions of Table 2. Table 2
4 Materials
Soft round copper wire
Hard copper wire
Special color round steel wire
UDG: 621.315.31
GB 3953—83
Specification range nm
0.020~14.00
0.020~14.00
1.50~ 5.00
Round copper wire shall be made of hot-rolled black round copper rod in accordance with the provisions of GB3952-83 "Electrical round copper rod". 5 Dimensional deviation
The deviation of the nominal diameter of round copper wire shall comply with the provisions of Table 3. 5.1
5.2 The difference (value) between the maximum and minimum diameters measured on a section of the round copper wire perpendicular to the axis shall not exceed the absolute value of the nominal diameter deviation.
Promulgated by the National Bureau of Standards on November 26, 1983
Implemented on October 1, 1984
Mechanical properties
Nominal diameter d
0.020~0.025
0.026-0.125
0.126 ~0.400
0.401 ~ 14.00
The mechanical properties of round copper wire shall comply with the provisions of Table 4. Electrical properties
The resistivity of round copper wire shall comply with the provisions of Table 5. TR type
Nominal diameter
GB3953—B3
Tensile strength
N·mm\
Not less than
t 0,002
±1%d*
Tensile weakness
TYT type
1.1—81 "Standardization
, when calculating the elasticity, the standard shift diameter is 0,4[-1,101m, and the one decimal place is retained, and the one greater than 11.000mm is retained. The provisions of the C section of the GH1 Guiding Principles are revised. Nominal vertical diameter
GB 3858--83
Continued Table 4Www.bzxZ.net
Tensile strength
, elongation
Tensile strength
The corresponding properties of the larger nominal diameter value are adopted. Note: When the nominal diameter value is between the two adjacent values listed in Table 5, the physical parameters of copper wire at 20℃ should be taken as follows: density
linear expansion coefficient
temperature coefficient of resistance
8.89g/cm3
0.000 017 C -1
.·0.00383℃1
..-0.003 81 ℃--
TY, TYT type Nominal diameter 2.00mm and above......0.003 77 C1
Nominal diameter below 2.00mm
Appearance
Reading The surface of the copper wire should be smooth and clean, and there should be no defects that are not consistent with good products! 9 Delivery requirements
9.1 Round copper wires should be delivered in coils or coils. Each coil or coil of round copper wire should be a whole wire. No fraudulent welding or twisting is allowed, except for the welding of copper rods in the manufacturing process and before the finished product is molded.
.2 The net weight of each coil or coil of round copper wire with a nominal diameter of 6.00mm or below shall comply with the provisions of Table 6. For a nominal diameter of more than 6.00mm, the weight shall be agreed upon by both parties. According to the agreement between the two parties, round copper wires of any weight are allowed to be delivered. Table 6
Nominal diameter
0.020-0.025
0.030~0.040
0.050-0.060
0.070~0.100
0.110 ~ 0.150
0,160~0.250
0.260~0,400
0.410 -0.600
0.630 ~0.800
0.820~1.000
1.01 -2.00
2.01 4.00
10 Acceptance rules and test methods
The weight of each round copper wire
is not less than
not less than 150% of the standard
weight
the quantity of delivery
is not greater than 15% of the total weight of delivery
the products shall be shipped only after they have passed the inspection by the manufacturer. Each batch of products shipped shall be accompanied by the manufacturer's product quality inspection certificate. The products shall be inspected in accordance with the provisions of Table 7.
Inspection items
Mechanical properties
Resistivity
Article number of this standard
Acceptance rules
JB1071—77
JB1071-77
JB1071--77
GB 3048.2—83
GB3953-83
10.31% sampling for each batch, but not less than 3 plates (circles): when the batch is large, no more than 10 plates (circles). If the first test result is unqualified, double the number of samples should be taken for the second test of the unqualified items. If there are still unqualified results, each plate (circle) should be checked. 11 Packaging and marking
11.1 Round copper wires are indicated by model, diameter and this standard number. For example, the nominal diameter of hard round copper wire is 2.00mm, which is indicated as: TY-2.00GB3953-8311.2 Round copper wires should be neatly wound and properly packaged. When coiled, the last layer should keep a proper distance from the edge of the coil side plate. 11.3 Each coil or coil of round copper wire should be attached with a label indicating: Manufacturer name
Model and specification
Gross weight and net weight kg
Date of manufacture year and month
This standard number GB3953-83
Additional instructions:
This standard was proposed by the Ministry of Machinery Industry of the People's Republic of China. This standard is under the jurisdiction of the Shanghai Cable Research Institute of the Ministry of Machinery Industry, and was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. Deng Benxiang is the person in charge of drafting this standard.
From the date of implementation of this standard, the former Ministry of Machinery Industry Standard JB647--77 "Round Copper Wire" will be invalid.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Electrical Round Copper Wire
Round copper wirefor electrical purposes The provisions of this standard are in accordance with the provisions of the International Electrotechnical Commission (IEC) 28. Scope of application
This standard applies to round copper wires used in the manufacture of wires and cables and motors and electrical appliances. 2 Model
The round copper wire models are shown in Table 1.
3 Specifications
The specifications of round copper wires are expressed in nominal diameters, and their specifications shall comply with the provisions of Table 2. Table 2
4 Materials
Soft round copper wire
Hard copper wire
Special color round steel wire
UDG: 621.315.31
GB 3953—83
Specification range nm
0.020~14.00
0.020~14.00
1.50~ 5.00
Round copper wire shall be made of hot-rolled black round copper rod in accordance with the provisions of GB3952-83 "Electrical round copper rod". 5 Dimensional deviation
The deviation of the nominal diameter of round copper wire shall comply with the provisions of Table 3. 5.1
5.2 The difference (value) between the maximum and minimum diameters measured on a section of the round copper wire perpendicular to the axis shall not exceed the absolute value of the nominal diameter deviation.
Promulgated by the National Bureau of Standards on November 26, 1983
Implemented on October 1, 1984
Mechanical properties
Nominal diameter d
0.020~0.025
0.026-0.125
0.126 ~0.400
0.401 ~ 14.00
The mechanical properties of round copper wire shall comply with the provisions of Table 4. Electrical properties
The resistivity of round copper wire shall comply with the provisions of Table 5. TR type
Nominal diameter
GB3953—B3
Tensile strength
N·mm\
Not less than
t 0,002
±1%d*
Tensile weakness
TYT type
1.1—81 "Standardization
, when calculating the elasticity, the standard shift diameter is 0,4[-1,101m, and the one decimal place is retained, and the one greater than 11.000mm is retained. The provisions of the C section of the GH1 Guiding Principles are revised. Nominal vertical diameter
GB 3858--83
Continued Table 4Www.bzxZ.net
Tensile strength
, elongation
Tensile strength
The corresponding properties of the larger nominal diameter value are adopted. Note: When the nominal diameter value is between the two adjacent values listed in Table 5, the physical parameters of copper wire at 20℃ should be taken as follows: density
linear expansion coefficient
temperature coefficient of resistance
8.89g/cm3
0.000 017 C -1
.·0.00383℃1
..-0.003 81 ℃--
TY, TYT type Nominal diameter 2.00mm and above......0.003 77 C1
Nominal diameter below 2.00mm
Appearance
Reading The surface of the copper wire should be smooth and clean, and there should be no defects that are not consistent with good products! 9 Delivery requirements
9.1 Round copper wires should be delivered in coils or coils. Each coil or coil of round copper wire should be a whole wire. No fraudulent welding or twisting is allowed, except for the welding of copper rods in the manufacturing process and before the finished product is molded.
.2 The net weight of each coil or coil of round copper wire with a nominal diameter of 6.00mm or below shall comply with the provisions of Table 6. For a nominal diameter of more than 6.00mm, the weight shall be agreed upon by both parties. According to the agreement between the two parties, round copper wires of any weight are allowed to be delivered. Table 6
Nominal diameter
0.020-0.025
0.030~0.040
0.050-0.060
0.070~0.100
0.110 ~ 0.150
0,160~0.250
0.260~0,400
0.410 -0.600
0.630 ~0.800
0.820~1.000
1.01 -2.00
2.01 4.00
10 Acceptance rules and test methods
The weight of each round copper wire
is not less than
not less than 150% of the standard
weight
the quantity of delivery
is not greater than 15% of the total weight of delivery
the products shall be shipped only after they have passed the inspection by the manufacturer. Each batch of products shipped shall be accompanied by the manufacturer's product quality inspection certificate. The products shall be inspected in accordance with the provisions of Table 7.
Inspection items
Mechanical properties
Resistivity
Article number of this standard
Acceptance rules
JB1071—77
JB1071-77
JB1071--77
GB 3048.2—83
GB3953-83
10.31% sampling for each batch, but not less than 3 plates (circles): when the batch is large, no more than 10 plates (circles). If the first test result is unqualified, double the number of samples should be taken for the second test of the unqualified items. If there are still unqualified results, each plate (circle) should be checked. 11 Packaging and marking
11.1 Round copper wires are indicated by model, diameter and this standard number. For example, the nominal diameter of hard round copper wire is 2.00mm, which is indicated as: TY-2.00GB3953-8311.2 Round copper wires should be neatly wound and properly packaged. When coiled, the last layer should keep a proper distance from the edge of the coil side plate. 11.3 Each coil or coil of round copper wire should be attached with a label indicating: Manufacturer name
Model and specification
Gross weight and net weight kg
Date of manufacture year and month
This standard number GB3953-83
Additional instructions:
This standard was proposed by the Ministry of Machinery Industry of the People's Republic of China. This standard is under the jurisdiction of the Shanghai Cable Research Institute of the Ministry of Machinery Industry, and was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. Deng Benxiang is the person in charge of drafting this standard.
From the date of implementation of this standard, the former Ministry of Machinery Industry Standard JB647--77 "Round Copper Wire" will be invalid.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 1388-2002 Compound Swing Jaw Crusher
- GB 4706.73-2004 Particular requirements for safety of whirlpool bathtubs for household and similar electrical appliances
- GB 16003-1995 Diagnostic criteria for Kaschin-Beck disease
- GB/T 5509-1985 Grain and oil inspection powder determination method for magnetic metal content
- JB/T 8784-1998 Technical requirements for drum sand-falling machine
- DL 5031-1994 Technical Specification for Construction and Acceptance of Electric Power Construction (Pipeline)
- GB 50252-1994 Uniform standard for inspection and assessment of industrial installation engineering quality
- HG 21529-1995 Plate type flat welding flange hand hole. Attached picture
- GB/T 3207-1988 Silver Bright Steel
- GB/T 5363-1995 Motorcycle and moped engine bench test methods
- GB/T 4122.4-2002 Packaging trerm-Wooden containers
- GB 5294-2001 Occupational exposure personal monitoring specification External exposure monitoring
- JB/T 9883-1999 Test of column accuracy of modular machine tools
- GB 16541-1996 Safety technical requirements for shaft cage hoisting signal systems
- CECS : 8997 Construction and acceptance specifications for integrated wiring systems for buildings and building complexes CECS89:97
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]